The DOI matches its Crossref record.
Exercise echocardiography versus 201Tl single-photon emission computed tomography in evaluation of coronary artery disease. Analysis of 292 patients.
Abstract
BACKGROUND: Exercise echocardiography (digital cine-loop technique) and 201Tl single-photon emission computed tomography (SPECT) were performed simultaneously in 292 patients being evaluated for coronary artery disease. METHODS AND RESULTS: Pretreadmill and posttreadmill echocardiographic images of diagnostic quality were obtained in 289 patients, and the left ventricle was divided into anterior, inferior, and lateral regions. Any wall motion or perfusion abnormality observed within each region was classified as totally reversible, fixed, or partially reversible. Exercise echocardiography and SPECT were normal in 137 patients and abnormal in 118 (88% agreement). Equal numbers of regional abnormalities were detected by one test when missed by the other. The two tests had an 82% agreement in detecting the same type of finding within the regions analyzed. SPECT detected more reversible abnormalities than echocardiography, whereas echocardiography detected more fixed abnormalities than SPECT: Regions with a fixed abnormality by echocardiography frequently showed partial reversibility of a perfusion defect by SPECT: Nearly one third of regions with fixed perfusion defects by SPECT demonstrated normal resting function or reversible abnormalities by echocardiography. Sensitivity for coronary artery disease by angiography (greater than or equal to 50% diameter stenosis) in 112 patients was similar for the two tests, ranging from 58% and 61% (echocardiography and SPECT, respectively) for one-vessel disease to 94% for three-vessel disease. The specificities for echocardiography and SPECT were 88% and 81%, respectively. CONCLUSIONS: Exercise echocardiography had a diagnostic accuracy comparable to that of SPECT for the detection of regional abnormalities produced by significant coronary artery disease. A greater number of abnormal regions were detected with the combined use of both tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
van Melle, J. P., Bot, M., de Jonge, P., de Boer, R. A., van Veldhuisen, D. J., & Whooley, M. A. (2010) · Diabetes Care · doi:10.2337/dc10-0286 · Cited by 159
CHEITLIN, M., ARMSTRONG, W., AURIGEMMA, G., BELLER, G., BIERMAN, F., DAVIS, J., DOUGLAS, P., FAXON, D., GILLAM, L., & KIMBALL, T. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00685-0 · Cited by 107
Metadata
- Authors
- Quiñones, M. A., Verani, M. S., Haichin, R. M., Mahmarian, J. J., Suarez, J., & Zoghbi, W. A.
- Venue
- Circulation
- Published
- 1992-03
- Volume
- 85
- Issue
- 3
- Pages
- 1026-1031
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2049373023
- Cited by
- 316
- References
- 0
- FWCI
- 26.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exercise echocardiography versus 201Tl single-photon emission computed tomography in evaluation of coronary artery disease. Analysis of 292 patients. https://app.cochat.ai/papers/10.1161/01.cir.85.3.1026
- The paper
- Quiñones, M. A., Verani, M. S., Haichin, R. M., Mahmarian, J. J., Suarez, J., & Zoghbi, W. A. (1992). Exercise echocardiography versus 201Tl single-photon emission computed tomography in evaluation of coronary artery disease. Analysis of 292 patients. Circulation. https://doi.org/10.1161/01.cir.85.3.1026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.