Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 234

The DOI matches its Crossref record.

Transesophageal Doppler echocardiography in obstructive hypertrophic cardiomyopathy: Clarification of pathophysiology and importance in intraoperative decision making

Open access
Grigg, Leeanne E., Wigle, E.Douglas, Williams, William G., Daniel, Lorretta B., Rakowski, Harry·1992·Journal of the American College of Cardiology

Abstract

To better understand the pathophysiology of obstruction of left ventricular outflow in hypertrophic cardiomyopathy and to determine the value of intraoperative transesophageal Doppler echocardiography in decision making, 32 consecutive patients undergoing ventriculomyectomy were assessed. The mean preoperative left ventricular outflow gradient was 83 +/- 39 mm Hg and the mean basal septal width was 24 +/- 6 mm. Compared with transesophageal findings in 10 normal control subjects, the mitral leaflets were longer and the coaptation point was abnormal in the patients with obstructive hypertrophic cardiomyopathy (anterior and posterior leaflet lengths in the patients were 31 +/- 4 vs. 22 +/- 3 mm in the control group [p less than 0.00001] and 20 +/- 2 vs. 15 +/- 3 mm in the control group [p less than 0.00001]). The coaptation point in the patient group was in the body of the leaflets at a mean of 9 +/- 2 mm from the anterior leaflet tip, whereas it was at or within 3 mm of the leaflet tip in the normal group. During early systole, the distal third to half of the anterior mitral leaflet angled sharply anteriorly and superiorly (systolic anterior motion), resulting in leaflet-septal contact and incomplete mitral leaflet coaptation in mid-systole. This caused the formation of a funnel, composed of the distal parts of both leaflets, that allowed a jet of posteriorly directed mitral regurgitation to occur in mid- and late systole. The sequence of events in systole was eject/obstruct/leak. Transesophageal echocardiography was also helpful in planning the extent of the resection, assessing the immediate result and excluding important complications. In successful cases, the post-myectomy study showed 1) a dramatic thinning of the septum, with widening of the left ventricular outflow tract to a width similar to that in the normal subjects, 2) resolution of systolic anterior motion and the left ventricular outflow tract color mosaic, and marked reduction or abolition of mitral regurgitation despite persistence of abnormal mitral leaflet length and an abnormal mitral leaflet coaptation point. The routine use of transesophageal echocardiography in patients undergoing surgical myectomy for the treatment of obstructive hypertrophic cardiomyopathy is recommended.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(92)90135-a

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 234

Metadata

Authors
Grigg, L. E., Wigle, E. D., Williams, W. G., Daniel, L. B., & Rakowski, H.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1992-07
Volume
20
Issue
1
Pages
42-52
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2094654105
Cited by
234
References
0
FWCI
4.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transesophageal Doppler echocardiography in obstructive hypertrophic cardiomyopathy: Clarification of pathophysiology and importance in intraoperative decision making. https://app.cochat.ai/papers/10.1016/0735-1097(92)90135-a
The paper
Grigg, L. E., Wigle, E. D., Williams, W. G., Daniel, L. B., & Rakowski, H. (1992). Transesophageal Doppler echocardiography in obstructive hypertrophic cardiomyopathy: Clarification of pathophysiology and importance in intraoperative decision making. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(92)90135-a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.