Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: A basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVES This study assessed the incremental prognostic implications of normal and equivocal exercise technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) and sought to determine its incremental prognostic value, impact on patient management and cost implications. BACKGROUND The prognostic implications of Tc-99m sestamibi SPECT are not well defined, and risk stratification using this test has not been explored. METHODS We studied 1,702 patients referred for exercise Tc-99m sestamibi SPECT who were followed up for a mean (+/- SD) of 20 +/- 5 months. Patients with previous percutaneous transluminal coronary angioplasty or coronary artery bypass surgery were excluded. The SPECT studies were assessed using semiquantitative visual analysis. Cardiac death and myocardial infarction were considered "hard" events, and coronary angioplasty and bypass surgery > 60 days after testing were considered "soft" events. RESULTS Of the 1,702 patients studied, 1,131 had normal or equivocal scan results. A total of 10 events occurred in this group (1 cardiac death and 1 myocardial infarction [0.2% hard events]; 4 coronary angioplasty and 4 bypass surgery procedures [0.7% soft events]). The rates of hard events and referral to catheterization after SPECT were similarly low in patients with a low (< 0.15), intermediate (0.15 to 0.85) and high (> 0.85) post-exercise treadmill test (ETT) likelihood of coronary artery disease. With respect to scan type, patients with normal, probably normal or equivocal scan results had similarly low hard event rates. In the 571 patients with abnormal scan results, there were 43 hard events (7.5%) and 42 soft events (7.4%) (p < 0.001 vs. 1,131 patients with normal scan results for both). When the complete spectrum of scan responses was considered, SPECT provided incremental prognostic value in all patient subgroups analyzed. However, the nuclear scan was cost-effective only in patients with interpretable exercise ECG responses and an intermediate to high post-ETT likelihood of coronary artery disease and in those with uninterpretable exercise ECG responses and an intermediate to high pre-ETT likelihood of coronary artery disease. CONCLUSIONS Normal or equivocal exercise Tc-99m sestamibi study results are associated with a benign prognosis, even in patients with a high likelihood of coronary artery disease. Although incremental prognostic value is added by nuclear testing in all patient subgroups, a testing strategy incorporating nuclear testing proved to be cost-effective only in the groups with an intermediate to high likelihood of coronary artery disease before scanning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
BMPD statistical software manual
Dixon, W. (1988) · University of California Press eBooks · Cited by 2,536
Berman, D. S., Kiat, H., Friedman, J. D., Wang, F. P., Van Train, K., Matzer, L., Maddahi, J., & Germano, G. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90557-h · Cited by 528
Self-citationLadenheim, M. L., Pollock, B. H., Rozanski, A., Berman, D. S., Staniloff, H. M., Forrester, J. S., & Diamond, G. A. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80454-5 · Cited by 440
Self-citationPrognostic value of thallium-201 myocardial perfusion imaging. A diagnostic tool comes of age.
Brown, K. A. (1991) · Circulation · doi:10.1161/01.cir.83.2.363 · Cited by 390
Diamond, G. A., Staniloff, H. M., Forrester, J. S., Pollock, B. H., & Swan, H. J. C. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80072-2 · Cited by 276
Self-citationMarzullo, P., Parodi, O., Reisenhofer, B., Sambuceti, G., Picano, E., Distante, A., Gimelli, A., & L'Abbate, A. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90733-s · Cited by 234
Machecourt, J., Longère, P., Fagret, D., Vanzetto, G., Wolf, J. E., Polidori, C., Comet, M., & Denis, B. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90597-5 · Cited by 207
Exercise Thallium-201 Scintigraphy in the Diagnosis and Prognosis of Coronary Artery Disease
Kotler, T. S., & Diamond, G. A. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-9-684 · Cited by 201
Self-citationTrain, K. F. V., Garcia, E. V., Maddahi, J., Areeda, J., Cooke, C. D., Kiat, H., Silagan, G., Folks, R., Friedman, J. D., & Matzer, L. (1994) · PubMed · Cited by 188
Self-citationLadenheim, M. L., Kotler, T. S., Pollock, B. H., Berman, D. S., & Diamond, G. A. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90798-3 · Cited by 159
Self-citationStratmann, H. G., Williams, G. A., Wittry, M. D., CHAITMAN, B. R., & Miller, D. D. (1994) · Circulation · doi:10.1161/01.cir.89.2.615 · Cited by 148
Maddahi, J., Kiat, H., Train, K. F. V., Prigent, F., Friedman, J. D., Garcia, E. V., Alazraki, N. P., DePuey, E. G., Nichols, K., & Berman, D. S. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90613-6 · Cited by 148
Self-citationMelin, J. A., Wijns, W. C., Vanbutsele, R., Robert, A. R., Coster, P. D., BRASSEUR, L. A., Beckers, C., & Detry, J. M. (1985) · Circulation · doi:10.1161/01.cir.71.3.535 · Cited by 133
Wackers, F. J. T., Russo, D. J., Russo, D., & Clements, J. P. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80247-3 · Cited by 132
Christian, T. F., Miller, T. D., Bailey, K. R., & Gibbons, R. J. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-121-11-199412010-00001 · Cited by 103
Prognostic value of normal technetium-99m-sestamibi cardiac imaging.
Brown, K. A., Altland, E., & Rowen, M. (1994) · PubMed · Cited by 91
Kiat, H., Train, K. F. V., Maddahi, J., Corbett, J. R., Nichols, K., McGhie, A. I., Akers, M. S., Friedman, J. D., Roy, L. T., & Berman, D. S. (1990) · American Heart Journal · doi:10.1016/0002-8703(90)90234-o · Cited by 53
Self-citation
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
The clinical implications of endothelial dysfunction
Widlansky, M. E., Gokce, N., Keaney, J. F., & Vita, J. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00994-x · Cited by 1,749
Hachamovitch, R., Hayes, S. W., Friedman, J. D., Cohen, I., & Berman, D. S. (2003) · Circulation · doi:10.1161/01.cir.0000072790.23090.41 · Cited by 1,563
Self-citationFihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Metadata
- Authors
- Berman, D. S., Hachamovitch, R., Kiat, H., Cohen, I., Cabico, J. A., Wang, F. P., Friedman, J. D., Germano, G., Van Train, K., & Diamond, G. A.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1995-09
- Volume
- 26
- Issue
- 3
- Pages
- 639-647
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2024951927
- Cited by
- 589
- References
- 19
- FWCI
- 16.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.