The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“where the maximum theoretical value for the pH sensitivity of the SiO 2 gate dielectric at this range of pH is 47-50 mV dec À1 .22”
From Specific and label-free femtomolar biomarker detection with an electrostatically formed nanowire biosensor (2013) · cites this paper as [22]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,436
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Self-citationSite-binding model of the electrical double layer at the oxide/water interface
Yates, D. E., Levine, S., & Healy, T. W. (1974) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19747001807 · Cited by 1,339
Multisite proton adsorption modeling at the solid/solution interface of (hydr)oxides: A new approach
Hiemstra, T., van Riemsdijk, W. H., & Bolt, G. H. (1989) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(89)90284-1 · Cited by 838
Basic properties of the electrolyte—SiO2—Si system: Physical and theoretical aspects
Siu, W. M., & Cobbold, R. S. C. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19690 · Cited by 268
Zeta potential measurements of Ta2O5 and SiO2 thin films
Bousse, L. J., Mostarshed, S., Shoot, B. V. D., de Rooij, N. F., Gimmel, P., & Göpel, W. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90130-z · Cited by 146
Bergveld, P., van Hal, R. E. G., & Eijkel, J. C. T. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96887-5 · Cited by 58
Self-citationISFET responses on a stepwise change in electrolyte concentration at constant pH
van Kerkhof, J. C., Eijkel, J. C. T., & Bergveld, P. (1994) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(94)87056-x · Cited by 32
Self-citation
Cited by
Sorted by citations
Items 301–309 of 309
Sufiyan, N., & Sharma, A. (2025) · International Conference for Emerging Technology (INCET) · doi:10.1109/incet64471.2025.11140900
Sharma, K., Sinduja, M., Ritik, Bhadauria, V., & Punetha, D. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-96-8690-2_30
Mello, H. J. N. P. D., Dalgleish, S., Ligorio, G., Mulato, M., & List, E. J. W. (2026) · Applied Physics A · doi:10.1007/s00339-026-09485-3
Mise en œuvre d'un capteur chimique et biologique à base de nanofils de silicium
Wenga, G. (2013) · theses.fr (ABES) · doi:10.70675/24066012z257bz46c2z80d8zd69d0a23c661
Samal, S., Kumar, A., & Mishra, G. P. (2026) · Journal of Electronic Materials · doi:10.1007/s11664-026-12928-5
Raghuveera, E., Kar, P., Kumar, N., Lenka, T. R., & Nguyen, H. P. T. (2026) · Microsystem Technologies · doi:10.1007/s00542-026-06099-w
Conductivity Preservation of Aryl Diazonium-Functionalized Bilayer Graphene Probed by Operando Hall
Molavi, B., Bazan, C. M., Vuu, T., Cimmino, J., Côté, S., Côté, M., Bouilly, D., & Szkopek, T. (2026) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.6c00919
Exploring pH Detection in DG-ISFET: Comparative Analysis of Single and Double-Gate Modes
Soni, U., Naugarhiya, A., Sahu, C., & Goel, N. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-92-0217-1_21
Metadata
- Authors
- van Hal, R. E. G., Eijkel, J. C. T., & Bergveld, P.
- Affiliations
- University of Twente (NL)
- ORCID
- Eijkel, J.C.T.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 1995-03
- Volume
- 24
- Issue
- 1-3
- Pages
- 201-205
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2165127612
- Cited by
- 311
- References
- 8
- Citations by year
- 2026: 9 · 2025: 10 · 2024: 14 · 2023: 12 · 2022: 13 · 2021: 18 · 2020: 20 · 2019: 17 · 2018: 20 · 2017: 25 · 2016: 19 · 2015: 19 · 2014: 15 · 2013: 23 · 2012: 11
- FWCI
- 0.31
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Sensors and Actuators B Chemical (publishedVersion)
- University of Twente Research Information (publishedVersion, other-oa)
- University of Twente Research Information (submittedVersion, other-oa)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- ion-sensitive field-effect transistor, pH sensitivity, buffering capacity, double-layer capacitance, differential capacitance, Gouy-Chapman-Stern theory, electrolyte concentration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review