The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
High-density oligonucleotide arrays
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light-generated oligonucleotide arrays for rapid DNA sequence analysis.
Pease, A. C., Solas, D., Sullivan, E. J., Cronin, M. T., Holmes, C. P., & Fodor, S. P. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.11.5022 · Cited by 1,367
McBride, L. J., & Caruthers, M. H. (1983) · Tetrahedron Letters · doi:10.1016/s0040-4039(00)81376-3 · Cited by 516
Synthesis of DNA via deoxynudeoside H-phosphonate Intermediates
Froehler, B. C., Ng, P. G., & Matteucci, M. D. (1986) · Nucleic Acids Research · doi:10.1093/nar/14.13.5399 · Cited by 347
Arrays of complementary oligonucleotides for analysing the hybridisation behaviour of nucleic acids
Southern, E. M., Case-Green, S. C., EIder, J. K., Johnson, M., Mir, K. U., Wang, L., & Williams, J. C. (1994) · Nucleic Acids Research · doi:10.1093/nar/22.8.1368 · Cited by 227
Cited by
Development of the Human Infant Intestinal Microbiota
Palmer, C., Bik, E. M., DiGiulio, D. B., Relman, D. A., & Brown, P. O. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050177 · Cited by 2,877
Inkjet Printing for Materials and Devices
Calvert, P. (2001) · Chemistry of Materials · doi:10.1021/cm0101632 · Cited by 1,822
Effects of synthetic micro- and nano-structured surfaces on cell behavior
Flemming, R. G., Murphy, C. J., Abrams, G. A., Goodman, S. L., & Nealey, P. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00209-9 · Cited by 1,450
Expression profiling using microarrays fabricated by an ink-jet oligonucleotide synthesizer
Hughes, T. R., Mao, M., Jones, A. R., Burchard, J., Marton, M. J., Shannon, K. W., Lefkowitz, S. M., Ziman, M., Schelter, J. M., Meyer, M. R., et al. (2001) · Nature Biotechnology · doi:10.1038/86730 · Cited by 1,298
Self-citationReddington, E., Sapienza, A., Gurau, B., Viswanathan, R., Sarangapani, S., Smotkin, E. S., & Mallouk, T. E. (1998) · Science · doi:10.1126/science.280.5370.1735 · Cited by 946
Metadata
- Authors
- Blanchard, A. P., Kaiser, R. J., & Hood, L. E.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 11
- Issue
- 6-7
- Pages
- 687-690
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2053537872
- Cited by
- 333
- References
- 4
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-density oligonucleotide arrays. https://app.cochat.ai/papers/10.1016/0956-5663(96)83302-1
- The paper
- Blanchard, A. P., Kaiser, R. J., & Hood, L. E. (1996). High-density oligonucleotide arrays. Biosensors and Bioelectronics. https://doi.org/10.1016/0956-5663(96)83302-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.