Quantitative analysis of neovascularization of different PTFE-implants
The DOI matches its Crossref record.
Abstract
The process of neovascularization was analyzed in vivo in different expanded polytetrafluoroethylene (e-PTFE) implants which are frequently used in cardio-thoracic and vascular surgery. We have used the model of the hamster dorsal skinfold chamber which allows quantitative analysis of the microcirculation by means of intravital fluorescence microscopy. Pieces of approximately 1 mm2 of the cardiovascular patch (CVP, fibril length: 30 microns; n = 21), surgical membrane (SM, fibril length: 1 micron; n = 16), and soft tissue patch (STP, fibril length: 22 microns; n = 12) were implanted into the skinfold chambers. On day 10 after implantation, the functional density of newly formed microvessels was significantly (P less than 0.05) higher in CVP (145.0 +/- 10.9 cm-1) as compared to SM (688 +/- 13.9 cm-1) and STP (86.9 +/- 21.2 cm-1). In addition, CVP revealed a larger zone of neovascularization (311.6 +/- 19.4 microns) and the tightest integration (dynamic breaking strength: 17.9 +/- 3.0 cN/mm2) into the perigraft tissue, while SM demonstrated only few microvessels and no integration (6.0 +/- 1.9 cN/mm2) into the perigraft. None of the three different PTFE-implants revealed transmural ingrowth of capillaries. The internodal distance of PTFE implants seems to be the most important factor for neovascularization. Surgical membrane used for the replacement of passive biological membranes demonstrated, as is its purpose, little neovascularization and no integration into the perigraft tissue.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Angiogenesis in Tissue Engineering: Breathing Life into Constructed Tissue Substitutes
Laschke, M. W., Harder, Y., Amon, M., Martin, I., Farhadi, J., Ring, A., Torio-Padron, N., Schramm, R., Rücker, M., Junker, D., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2093 · Cited by 546
Self-citationAngiogenic and inflammatory response to biodegradable scaffolds in dorsal skinfold chambers of mice
Rücker, M., Laschke, M. W., Junker, D., Carvalho, C., Schramm, A., Mülhaupt, R., Gellrich, N.-C., & Menger, M. D. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.033 · Cited by 232
Self-citationBiomaterial–microvasculature interactions
Sieminski, A. L., & Gooch, K. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00149-6 · Cited by 155
Intravital microscopy evaluation of angiogenesis and its effects on glucose sensor performance
Koschwanez, H. E., Reichert, W. M., & Klitzman, B. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32630 · Cited by 15
Percutaneous Window Chamber Method for Chronic Intravital Microscopy of Sensor—Tissue Interactions
Koschwanez, H. E., Klitzman, B., & Reichert, W. M. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200608 · Cited by 9
Metadata
- Authors
- MENGER, M., WALTER, P., HAMMERSEN, F., & MESSMER, K.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 1990
- Volume
- 4
- Issue
- 4
- Pages
- 191-196
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W2062430573
- Cited by
- 35
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.