Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record.

Selective detection of phosphopeptides in complex mixtures by electrospray liquid chromatography/mass spectrometry

Huddleston, Michael J., Annan, Roland S., Bean, Mark F., Carr, Steven A.·1993·Journal of the American Society for Mass Spectrometry

Abstract

A mass spectrometry-based method that does not involve the use of radiolabeling was developed for selective detection of phosphopeptides in complex mixtures. Mixtures of phosphorylated and nonphosphorylated peptides at the low picomole level are analyzed by negative ion electrospray liquid chromatography/mass spectrometry using C-18 packed fused-silica columns (≤320-μm i.d.). Peptides and phosphopeptides in the chromatographic eluant undergo collision-induced dissociation in the free-jet expansion region prior to the mass analyzing quadrupole. Using relatively high collisional excitation potentials, phospho|peptides containing phosphoserine, phosphothreonine, and phosphotyrosine fragment to yield diagnostic ions at m/z 63 and 79 corresponding to PO2 (-); and PO3 (-), respectively. Chromatographic peaks containing phosphopeptides are indicated where these diagnostic ions maximize. The highest sensitivity for phosphopeptide detection is obtained using selected-ion monitoring for m/z 63 and 79. Full-scan mass spectra that exhibit the diagnostic phosphopeptide fragment ions, together with pseudomolecular ions, may be obtained by stepping the collisional excitation potential from a high value during the portion of each scan in which the low-mass-to-charge ratio diagnostic marker ions are being detected to a lower value while the upper mass-to-charge ratio range is being scanned. Good sensitivity for phosphopeptide detection was achieved using standard trifluoroacetic acid containing mobile phases for reversed-phase high-performance liquid chromatography. Data illustrating the selectivity and sensitivity of the approach are presented for mixtures of peptides and phosphopeptides containing the three commonly phosphorylated amino acids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/1044-0305(93)80049-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 242

Metadata

Authors
Huddleston, M. J., Annan, R. S., Bean, M. F., & Carr, S. A.
Venue
Journal of the American Society for Mass Spectrometry
Published
1993-09-01
Volume
4
Issue
9
Pages
710-717
ISSN
1044-0305 (ISSN-L)
OpenAlex
W2009682799
Cited by
242
References
0
FWCI
8.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selective detection of phosphopeptides in complex mixtures by electrospray liquid chromatography/mass spectrometry. https://app.cochat.ai/papers/10.1016/1044-0305(93)80049-5
The paper
Huddleston, M. J., Annan, R. S., Bean, M. F., & Carr, S. A. (1993). Selective detection of phosphopeptides in complex mixtures by electrospray liquid chromatography/mass spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/1044-0305(93)80049-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.