The DOI matches its Crossref record.
Ion formation from charged droplets: Roles of geometry, energy, and time
Abstract
The formation of ions from the charged droplets produced in the several spray ionization techniques is viewed as an activated rate process involving field-assisted desorption, in accord with the ideas first set forth by Iribame and Thomson. The novel features of the present treatment are particularly relevant to the unique ability of electrospray ionization to transform large molecules in solution to free ions in the gas phase, with extensive multiple charging. These new features stem mainly from the realization that the spacing of charges on a desorbed ion must relate to the spacing of charges on the surface of the droplet whence it came. The consequences of this "rule" can account for the existence of maxima and minima in the number of charges on the ions of a particular species as well as the nature of the distribution of ions among the intervening charge states. They also explain the dependence of charge state on the configuration in solution of the parent molecule of the desorbed ion. In addition, they provide insight into the sequence in time at which ions in the various charge states leave an evaporating droplet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Secondary Electrospray Ionization Ion Mobility Spectrometry/Mass Spectrometry of Illicit Drugs
Wu, C., Siems, W. F., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac9907235 · Cited by 278
Zamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Surfactant effects on protein structure examined by electrospray ionization mass spectrometry
Loo, R. R. O., Dales, N., & Andrews, P. C. (1994) · Protein Science · doi:10.1002/pro.5560031109 · Cited by 184
Metadata
- Authors
- Fenn, J. B.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-07-01
- Volume
- 4
- Issue
- 7
- Pages
- 524-535
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2016717705
- Cited by
- 518
- References
- 0
- FWCI
- 16.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ion formation from charged droplets: Roles of geometry, energy, and time. https://app.cochat.ai/papers/10.1016/1044-0305(93)85014-o
- The paper
- Fenn, J. B. (1993). Ion formation from charged droplets: Roles of geometry, energy, and time. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/1044-0305(93)85014-o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.