The DOI matches its Crossref record.
Dosimetry in sonochemistry: the use of aqueous terephthalate ion as a fluorescence monitor
Open accessAbstract
The generation of HO radicals by acoustic cavitation in water was monitored by their reaction with terephthalic acid (TA) anion to produce fluorescent hydroxyterephthalate ions using a cleaning bath (38kHz) and a probe system (20, 40 and 60 kHz) as different sources of ultrasound. When using the ultrasonic bath as a source of energy for sonochemical studies, the shape of the reaction vessel is important. In the case of HO production from water (50 cm3), reaction in a conical flask (100 cm3) produces 2.75 times more radicals than a round-bottomed flask of the same capacity. The fluorescence yield (fluorescence intensity/ultrasound dosage) obtained using the conical flask and ultrasonic bath was similar to that for a probe operating at 40 kHz on the same volume of solution. For a probe system operating at 20, 40 and 60 kHz the greatest sonochemical efficiency was attained at the highest of these frequencies (60 kHz). For the probe system the fluorescence yield is directly proportional to power input and the concentration of TA. The fluorescence yield decreases as the temperature is increased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synthesis of M@TiO2 (M = Au, Pd, Pt) Core–Shell Nanocomposites with Tunable Photoreactivity
Zhang, N., Liu, S., Fu, X., & Xu, Y.-J. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp2009989 · Cited by 594
Lipid Extraction Methods from Microalgae: A Comprehensive Review
Ranjith Kumar, R., Hanumantha Rao, P., & Arumugam, M. (2015) · Frontiers in Energy Research · doi:10.3389/fenrg.2014.00061 · Cited by 402
Sonochemistry of carbohydrate compounds
Kardos, N., & Luche, J.-L. (2001) · Carbohydrate Research · doi:10.1016/s0008-6215(01)00081-7 · Cited by 263
The importance of ultrasonic parameters in the preparation of fuel cell catalyst inks
Pollet, B. G., & Goh, J. T. E. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2013.09.160 · Cited by 117
Nanophase iron-enhanced chemical reactivity of ground lunar soil
Wallace, W. T., Phillips, C. J., Jeevarajan, A. S., Chen, B., & Taylor, L. A. (2010) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2010.04.042 · Cited by 31
Metadata
- Authors
- Mason, T. J., Lorimer, J. P., Bates, D. M., & Zhao, Y.
- Venue
- Ultrasonics Sonochemistry
- Publisher
- Elsevier BV
- Published
- 1994
- Volume
- 1
- Issue
- 2
- Pages
- S91-S95
- ISSN
- 1350-4177 (ISSN-L)
- OpenAlex
- W1994742657
- Cited by
- 383
- References
- 0
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dosimetry in sonochemistry: the use of aqueous terephthalate ion as a fluorescence monitor. https://app.cochat.ai/papers/10.1016/1350-4177(94)90004-3
- The paper
- Mason, T. J., Lorimer, J. P., Bates, D. M., & Zhao, Y. (1994). Dosimetry in sonochemistry: the use of aqueous terephthalate ion as a fluorescence monitor. Ultrasonics Sonochemistry. https://doi.org/10.1016/1350-4177(94)90004-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.