Failure mechanisms in human vertebral cancellous bone
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Specimens of human vertebral cancellous bone were compressed to well past mechanical failure (15% strain) in the infero-superior direction. The mechanisms of failure were examined microscopically and histologically. The primary mechanism of failure was shown to be microscopic cracking rather than overt failure of the trabecular elements. The morphology of the cracks was consistent with an hypothesis that they were the result of shear stress (or strain) in the tissue. Complete fracture of trabeculae was confined to elements oriented transversely to the direction of loading. The tissue's ultimate strength and residual strength after compressive failure were both strongly correlated to tissue stiffness (R2 = 0.88 and R2 = 0.71, respectively). It is proposed that cancellous bone strength may be a consequence of the adaptation of bone stiffness to applied stresses. With removal of the load, all specimens recovered at least 94% of their original height. Implications of energy dissipation by microcracking for recovery and maintenance of overall trabecular architecture are discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The large reduction in apparent modulus that occurs with overloading (Figure 2b) results from damage within the trabeculae, namely microscopic cracking as opposed to overt fracture of individual trabeculae (104).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [104]
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Parfitt, A. M., Mathews, C. H., Villanueva, A. R., Kleerekoper, M., Frame, B., & Rao, D. S. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111096 · Cited by 1,545
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Basic orthopaedic biomechanics
Mow, V. C., & Hayes, W. C. (1991) · Medical Entomology and Zoology · Cited by 655
Pauwels, F. (1980) · Springer eBooks · doi:10.1007/978-3-642-67138-8 · Cited by 643
Koch, J. C. (1917) · American Journal of Anatomy · doi:10.1002/aja.1000210202 · Cited by 626
Structure, Function, and Adaptation of Compact Bone
Martin, R. B., & Burr, D. B. (1989) · Medical Entomology and Zoology · Cited by 476
Elements of hereditary solid mechanics
Rabotnov, I. N. (1980) · Medical Entomology and Zoology · Cited by 424
(1960) · Henry Ford Hospital medical bulletin · Cited by 397
Incidence of Colles' fracture in a North American community.
Owen, R. A., Melton, L. J., Johnson, K. A., Ilstrup, D. M., & Riggs, B. L. (1982) · American Journal of Public Health · doi:10.2105/ajph.72.6.605 · Cited by 309
Research works printed but not linked: 3
- Keaveny, 1992, Post-yield behavioral damage of bovine trabecular bone, Trans. Orthopaed. Res. Soc., 17, 161
- Nelson, 1991, Vertebral deformities in osteoporosis may be transient events: the “rebound” phenomenon, J. Bone Min. Res., 6, S275
- Weibel, 1980, Vol. 1
Cited by
Items 101–200 of 217
Yeni, Y. N., Christopherson, G. T., Turner, A. S., Les, C. M., & Fyhrie, D. P. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20128 · Cited by 39
Self-citationGoff, M. G., Lambers, F. M., Nguyen, T. M., Sung, J., Rimnac, C. M., & Hernandez, C. J. (2015) · Bone · doi:10.1016/j.bone.2015.05.020 · Cited by 38
Characterizing microcrack orientation distribution functions in osteonal bone samples
Wolfram, U., Schwiedrzik, J. J., Mirzaali, M. J., Bürki, A., Varga, P., Olivier, C., Peyrin, F., & Zysset, P. K. (2016) · Journal of Microscopy · doi:10.1111/jmi.12440 · Cited by 36
“…is not detectable using conventional clinical imaging modalities but decreases bone’s stiffness, strength and toughness and eventually leads to a collapse of whole bones (Fyhrie & Schaffler, 1994; Burr et al., 1997; Kopperdahl et al., 2000; Nalla et al., 2005; Ritchie et al., 2005; Ritchie, 2011).”
High Strain Rate Testing of Bovine Trabecular Bone
Pilcher, A., Wang, X., Kaltz, Z., Garrison, J. G., Niebur, G. L., Mason, J., Song, B., Cheng, M., & Chen, W. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000086 · Cited by 32
Experimental study of cancellous bone under large strains and a constitutive probabilistic model
Kefalas, V. A., & Eftaxiopoulos, D. A. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.10.006 · Cited by 36
Sensitivity of Multiple Damage Parameters to Compressive Overload in Cortical Bone
Morgan, E. F., Lee, J. J., & Keaveny, T. M. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1933916 · Cited by 34
Towards patient‐specific material modeling of trabecular bone post‐yield behavior
Carretta, R., Lorenzetti, S., & Müller, R. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2516 · Cited by 34
Localized Damage in Vertebral Bone Is Most Detrimental in Regions of High Strain Energy Density
Kopperdahl, D. L., Roberts, A. D., & Keaveny, T. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800864 · Cited by 35
Krammer, M., Dietl, R., Lumenta, C. B., Kettler, A., Wilke, H., Büttner, A., & Claes, L. (2001) · Acta Neurochirurgica · doi:10.1007/s007010100017 · Cited by 31
“to be the step before ®nal implant bone failure [8].”
BackgroundAxial cyclic behavior of the bone–screw interface
İnceoğlu, S., Ehlert, M., Akbay, A., & McLain, R. F. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.12.009 · Cited by 31
A Review on Multiscale Bone Damage: From the Clinical to the Research Perspective
Buccino, F., Colombo, C., & Vergani, L. M. (2021) · Materials · doi:10.3390/ma14051240 · Cited by 33
Kim, Y.-H., Ha, K.-Y., Kim, K.-T., Chang, D., Park, H., Yoon, E.-J., & Kim, S.-I. (2021) · Scientific Reports · doi:10.1038/s41598-021-99751-6 · Cited by 29
Marrow edema variability in acute spine fractures
Brinckman, M. A., Chau, C., & Ross, J. S. (2014) · The Spine Journal · doi:10.1016/j.spinee.2014.09.032 · Cited by 29
“Traditionally, bone marrow edema has been attributed to the sequella of trabecular microfractures, with resultant edema and/or hemorrhage [19].”
BackgroundAxial-shear interaction effects on microdamage in bovine tibial trabecular bone
Wang, X., Guyette, J. P., Liu, X., Roeder, R. K., & Niebur, G. L. (2005) · European Journal of Morphology · doi:10.1080/09243860500095570 · Cited by 34
“Diffuse damage appeared as regions of stained bone with irregular edges, while microcracks exhibited distinct edges and showed permeation of stain into the bone (Fazzalari et al. 1998b; Fyhrie & Schaffler 1994; Wachtel and Keaveny 1997).”
BackgroundEffect of pelvis impact angle on stresses at the femoral neck during falls
Choi, W. J., & Robinovitch, S. N. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.04.015 · Cited by 29
High-speed X-ray visualization of dynamic crack initiation and propagation in bone
Zhai, X., Guo, Z., Gao, J., Kedir, N., Nie, Y., Claus, B., Sun, T., Xiao, X., Fezzaa, K., & Chen, W. W. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.045 · Cited by 27
Structural strength of cancellous specimens from bovine femur under cyclic compression
Endo, K., Yamada, S., Todoh, M., Takahata, M., Iwasaki, N., & TADANO, S. (2016) · PeerJ · doi:10.7717/peerj.1562 · Cited by 31
Tensile trabeculae--myth or reality?
Sverdlova, N. S. (2011) · PubMed · Cited by 24
Zhang, N., Magland, J. F., Rajapakse, C. S., Bhagat, Y. A., & Wehrli, F. W. (2013) · Medical Physics · doi:10.1118/1.4802085 · Cited by 23
Rajasekaran, S., Natarajan, R. N., Babu, J. N., Kanna, P. R. M., Shetty, A. P., & Andersson, G. B. J. (2011) · Spine · doi:10.1097/brs.0b013e3182041e3c · Cited by 25
Chaari, F., Markiewicz, É., & Drazétic, P. (2007) · International Journal of Crashworthiness · doi:10.1080/13588260701441142 · Cited by 22
“The reported works on the mechanical characterization showed that spongy bone behaves very similarly to cellular materials [ 10 , 11 , 12 ].”
Fatigue-caused damage in trabecular bone from clinical, morphological and mechanical perspectives
Mirzaali, M. J., Libonati, F., Böhm, C., Rinaudo, L., Cesana, B. M., Ulivieri, F. M., & Vergani, L. M. (2019) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2019.105451 · Cited by 24
Influence of Orthogonal Overload on Human Vertebral Trabecular Bone Mechanical Properties
Badiei, A., Bottema, M. J., & Fazzalari, N. L. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070706 · Cited by 21
Tough Cortical Bone‐Inspired Tubular Architected Cement‐Based Material with Disorder
Gupta, S., & Moini, R. (2024) · Advanced Materials · doi:10.1002/adma.202313904 · Cited by 30
Anatomy and Physiology of Skeletal Development
(2000) · Springer eBooks · doi:10.1007/0-387-21854-8_1 · Cited by 20
Micromechanical evaluation of bone microstructures under load
Müller, R., Boesch, T., Jarak, D., Stauber, M., Nazarian, A., Tantillo, M., & Boyd, S. K. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.452845 · Cited by 24
Wood, Z., Lynn, L., Nguyen, J. T., Black, M. A., Patel, M. K., & Barak, M. M. (2019) · Bone · doi:10.1016/j.bone.2019.08.002 · Cited by 21
Tommasini, S. M., Wearne, S. L., Hof, P. R., & Jepsen, K. J. (2008) · Bone · doi:10.1016/j.bone.2007.12.009 · Cited by 21
“Other factors contributing to the lower explanatory power for these regressions include 1) underestimation of FU of C3H vertebral bodies due to brittle failure mode; 2) variation in other matrix components [36,37]; and 3) architectural traits not measured in this study that could contribute to variation in more comple…”
BackgroundNazarian, A., Meier, D., Müller, R., & Snyder, B. D. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20931 · Cited by 20
PARFITT, A. M. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-375098-3.50006-8 · Cited by 23
Nazarian, A., Bauernschmitt, M., Eberle, C., Meier, D., Müller, R., & Snyder, B. D. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.09.014 · Cited by 17
“While shear properties of cancellous bone have been reported previously (Sammarco et al., 1971; Halawa et al., 1978; Stone et al., 1983; Fyhrie and Schaffler, 1994; Mitton et al., 1997), many of the torsion tests performed to determine these properties were conducted under conditions appropriate only for”
ResultMulder, L., van Ruijven, L. J., Koolstra, J. H., & van Eijden, T. M. G. J. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9345-3 · Cited by 18
A novel technique for micro-hole forming on skull with the assistance of ultrasonic vibration
Li, Z., Yang, D., Hao, W., Wu, T., Song, W. C., & Li, X. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.11.016 · Cited by 16
Ultrasonic vibration-assisted micro-hole forming on skull
Li, Z., Yang, D., Hao, W., Wu, S. H., Ye, Y., Chen, Z., & Li, X. (2015) · Proceedings of the Institution of Mechanical Engineers Part B Journal of Engineering Manufacture · doi:10.1177/0954405415611363 · Cited by 16
Rouhi, G., Vahdati, A., LI, X., & Sudak, L. J. (2015) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951941550061x · Cited by 16
Biomechanics of Vertebral Bone
Keaveny, T. M., & Buckley, J. M. (2006) · Elsevier eBooks · doi:10.1016/b978-012369390-7/50005-8 · Cited by 20
A Finite Element Beam-model for Efficient Simulation of Large-scale Porous Structures
Stauber, M., Huber, M., van Lenthe, H., Boyd, S. K., & Müller, R. (2004) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840410001656408 · Cited by 18
Multiscale modeling of human bone
Kwon, Y. W., & Clumpner, B. R. (2018) · Multiscale and Multidisciplinary Modeling Experiments and Design · doi:10.1007/s41939-018-0013-0 · Cited by 15
Hernandez, C. J. (2016) · Springer eBooks · doi:10.1007/978-1-4939-3305-1_2 · Cited by 14
Xiong, Y., Li, H., Wang, P., Liu, P., & Yan, Y. (2018) · Journal of Applied Polymer Science · doi:10.1002/app.46226 · Cited by 13
Endo, K., Takahata, M., Sugimori, H., Yamada, S., TADANO, S., Wang, J., Masahiro Todoh, A., Ito, Y. M., Takahashi, D., Kudo, K., et al. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.03.010 · Cited by 13
Guo, X., Zhou, J., Xu, Q., Lu, X., Liang, Y., Weng, J., & Shi, X. (2009) · The Anatomical Record · doi:10.1002/ar.21036 · Cited by 13
“Bone histomorphometry was determined as described in the literature (Gao and Wang, 2004).”
MethodAdams, M. F., Bayraktar, H. H., Keaveny, T. M., & Papdopoulos, P. (2003) · ACM/IEEE Conference on Supercomputing (SC) · doi:10.1145/1048935.1050177 · Cited by 13
“While these preliminary analyses are run using a 5-mm cubic sample of vertebral trabecular bone with a finite elasto-plasticity material constitution [28], more realistic material models which include trabecular tissue strength asymmetry [8] and damage [17] behavior are being implemented.”
MethodTsouknidas, A., Maliaris, G., Savvakis, S., & Michailidis, N. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.849342 · Cited by 12
Mahato, N. K. (2013) · The Spine Journal · doi:10.1016/j.spinee.2013.02.072 · Cited by 12
“The lumbosacral junction is quite unique in terms of its orientation and load distribution [1–4].”
BackgroundEffects of damage on the orthotropic material symmetry of bovine tibial trabecular bone
Liu, X., Wang, X., & Niebur, G. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00217-3 · Cited by 13
Lu, W. W., Luk, K., Cheung, K., Guixing, Q., Shen, J. X., Yuen, L., Ouyang, J., & Leong, J. C. Y. (2004) · Spine · doi:10.1097/00007632-200406010-00007 · Cited by 12
Post-yield relaxation behavior of bovine cancellous bone
Burgers, T. A., Lakes, R. S., García-Rodríguez, S., Piller, G. R., & Ploeg, H.-L. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.005 · Cited by 10
“Subsequent loading after the yield strain leads to increased damage (Fyhrie and Schaffler, 1994; Wachtel and Keaveny, 1997; Nagaraja et al., 2005), decreased strength (Keaveny et al.”
BackgroundResistance of equine tibiae and radii to side impact loads
Piskoty, G., Jäggin, S., Michel, S., Weisse, B., Terrasi, G. P., & Fürst, A. (2012) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.2012.00560.x · Cited by 10
Finite element prediction of fatigue damage growth in cancellous bone
Hambli, R., Frikha, S., Toumi, H., & Tavares, J. M. R. S. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1048687 · Cited by 10
Simulations of mechanical adaptation and their relationship to stress bearing in skeletal tissue
Hirschberg, J. (2005) · UWA Profiles and Research Repository (UWA) · Cited by 12
Local and global microarchitecture is associated with different features of bone biomechanics
Roux, J.-P., Boutroy, S., Bouxsein, M., Chapurlat, R. D., & Wegrzyn, J. (2020) · Bone Reports · doi:10.1016/j.bonr.2020.100716 · Cited by 9
Yeni, Y. N., Dix, M. R., Xiao, A., & Oravec, D. J. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105334 · Cited by 10
Novel techniques for high-resolution functional imaging of trabecular bone
Thurner, P. J., Müller, R., Kindt, J. H., Schitter, G., Fantner, G. E., Wyss, P., Sennhauser, U. J., & Hansma, P. K. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.595799 · Cited by 9
“In such investigations microcracks are usually classified for quantitative analysis as either internal or surface connected cracks (26-28).”
BackgroundFrisch, T., S�rensen, M., & Bretlau, P. (2001) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050000286 · Cited by 9
“Other types than the Frostian microcracks have been proposed to represent intravital microdamage in long bones, such as the so-called cross-hatched MDx [5, 10 , 29], diffuse microdamage [5], and interlamellar delamination in cortex [26].”
BackgroundA nonlinear micromechanical model for progressive damage of vertebral trabecular bones
Massarwa, E., Aboudi, J., Galbusera, F., Wilke, H., & Haj-Ali, R. M. (2017) · Journal of mechanics of materials and structures · doi:10.2140/jomms.2017.12.407 · Cited by 8
En bloc staining of bone under load does not improve dye diffusion into microcracks
Burr, D. B., Turner, C. H., Naick, P., Forwood, M. R., & Pidaparti, R. M. V. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00007-4 · Cited by 8
Siegmund, T. H., Allen, M. R., & Burr, D. B. (2010) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2010.04.009 · Cited by 7
“Compression failure of trabecular bone has been linked to the formation of shear damage zones within trabeculae (Fyhrie and Schaffler, 1994; Wenzel et al., 1996) and delaminations (Thurner et al., 2006, 2007), which are aligned with the long axis of the individual trabecula.”
BackgroundZenzes, M., Bortel, E. L., Fratzl, P., Mundlos, S., Schuetz, M., Schmidt, H., Duda, G. N., Witte, F., & Zaslansky, P. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.12.050 · Cited by 7
Spongy bone deformation mechanisms: Experimental and numerical studies
Chaari, F., Halgrin, J., Markiewicz, É., & Drazétic, P. (2009) · European Journal of Computational Mechanics · doi:10.13052/ejcm.18.67-79 · Cited by 6
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Mapping trabecular disconnection “hotspots” in aged human spine and hip
Aaron, J. E., Shore, P. A., Itoda, M., Morrison, R., Hartopp, A., Hensor, E. M. A., & Hordon, L. (2015) · Bone · doi:10.1016/j.bone.2015.04.009 · Cited by 7
An additively manufactured model for preclinical testing of cervical devices
Wahbeh, J. M., Hookasian, E., Lama, J., Alam, L., Park, S., Sangiorgio, S. N., & Ebramzadeh, E. (2023) · JOR Spine · doi:10.1002/jsp2.1285 · Cited by 5
“56 Therefore, gyroid specimens were tested in coronal plane compression from 10% to 35% in-fill densities.”
MethodMANAGING LOW‐BACK DISORDER RISK IN THE WORKPLACE
Marras, W. S., & Karwowski, W. (2021) · Wiley eBooks · doi:10.1002/9781119636113.ch22 · Cited by 6
The Effect on the Hip Muscle Activation of the Fall Direction and Knee Position During a Fall
Lee, K. J., Lim, K., & Choi, W. J. (2021) · Physical Therapy Korea · doi:10.12674/ptk.2021.28.1.84 · Cited by 5
Analyses of trabecular bone failure
Verhulp, E. E. (2006) · TU/e Research Portal · doi:10.6100/ir608109 · Cited by 8
“…the predicted apparent yield behavior for some of the models was close to the experimental reality, they failed to predict the typical descent in the load-displacement curve seen during compression of trabecular bone specimens (Røhl et al., 1991; Fyhrie and Schaffler, 1994; Keaveny et al., 1999).”
BackgroundResultInfluentialFunctional micro-imaging of soft and hard tissue using synchrotron light
Thurner, P. J., Wyss, P., Voide, R., Stauber, M., Müller, B., Stampanoni, M., Hubbell, J. A., Müller, R., & Sennhauser, U. J. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.559515 · Cited by 7
“In such investigations microcracks are usually classified for quantitative analysis as either internal or surface connected cracks (38-40).”
BackgroundRaftery, K. A., Levy, H. A., Adamson, L., Magera, C. A., Freedman, B. A., & Newell, N. (2026) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2026.106792 · Cited by 4
Risk Assessment of Bone Fracture During Space Exploration Missions to the Moon and Mars
Lewandowski, B. E., Myers, J. G., Nelson, E. S., Licatta, A., & Griffin, D. W. (2007) · NASA Technical Reports Server (NASA) · Cited by 6
Localized Trabecular Damage Adjacent to Interbody Fusion Devices
WARDEN, K. E., & Davy, D. T. (2010) · Spine · doi:10.1097/brs.0b013e3181ba0003 · Cited by 5
Bettamer, A. (2013) · theses.fr (ABES) · doi:10.70675/7d04b4bfza5b5z44dfz8f0cz49556bee8989 · Cited by 6
Tian, Y., Shi, X., Zhai, S., Liu, Y., Yang, Z., Wu, Y., & Chu, S. (2025) · BMC Oral Health · doi:10.1186/s12903-025-05559-5 · Cited by 3
“The elastic modulus of cancellous bone experiences a significant decrease once it surpasses the yield strength, as the internal structure of cancellous bone undergoes slight cracking [30, 31].”
Directional Tortuosity as a Predictor of Modulus Damage for Vertebral Cancellous Bone
Fyhrie, D. P., & Zauel, R. R. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029177 · Cited by 3
Self-citationSkeletal heterogeneity and the purposes of bone remodeling
PARFITT, A. M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813073-5.00030-7 · Cited by 4
Multi-scale modelling of the trabecular bone elastoplastic behaviour under compression loading
Jaziri, A., Rahmoun, J., Naceur, H., Drazétic, P., & Markiewicz, É. (2012) · European Journal of Computational Mechanics · doi:10.1080/17797179.2012.731255 · Cited by 4
“…1958-5829 online 2012 Taylor & Francis http://dx.doi.org/10.1080/17797179.2012.731255 http://www.tandfonline.com an established method for evaluating the mechanical competence of trabecular bone, due to its simplicity and its resemblance to the natural deformation (Fyhrie & Schaffler, 1994).”
MethodInfluentialBiomechanics of Vertebral Fracture
Whyne, C. M., McLachlin, S. D., Burke, M., & Hardisty, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-52634-8_2 · Cited by 3
NATALI, A. N., & Hart, R. T. (2005) · Kluwer Academic Publishers eBooks · doi:10.1007/0-306-47583-9_15 · Cited by 3
MICROSTRUCTURAL STRESSES AND STRAINS ASSOCIATED WITH TRABECULAR BONE MICRODAMAGE
Nagaraja, S. (2006) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 4
Portan, D. V., Kontaxis, L. C., Tselepidi, A., Papanicolaou, G. C., & Azamfirei, L. (2026) · Polymers · doi:10.3390/polym18161984 · Cited by 2
“This post-peak behavior is consistent with the collapse of porous structures, as reported in studies on trabecular bone mechanics, where initial strut failure leads to progressive densification and a transition toward a more compact, load-bearing configuration [51].”
Effect of variations in tissue-level ductility on human vertebral strength
Sadoughi, S., Scheidt, A. V., Nawathe, S., Zhu, S., Moini, A., & Keaveny, T. M. (2020) · Bone · doi:10.1016/j.bone.2020.115445 · Cited by 2
Lim, J. W. (2018) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-018-0032-0 · Cited by 2
Zehr, J. D., Watson, M. I., & Callaghan, J. P. (2023) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2023.105946 · Cited by 2
The mechanics of microdamage and microfracture in trabecular bone
Toal, V. R. (2013) · Cited by 3
Meeting report from the 24th annual meeting of the American society for bone and mineral research
Black, D. M., Bouillon, R., Ducy, P. F., Miller, P. D., Papapoulos, S. E., Ralston, S. H., Ross, P. A., Schipani, E., Seeman, E., Strewler, G. J., et al. (2002) · BoneKEy-Osteovision · doi:10.1138/2002065 · Cited by 2
A graph model to describe the network connectivity of trabecular plates and rods
Walle, M., Yeritsyan, D., Abbasian, M., Oftadeh, R., Müller, R., & Nazarian, A. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1384280 · Cited by 1
“Our motivation to investigate elastic modulus was based on fi ndings from other studies (Fyhrie and Schaf fl er, 1994; Keller, 1994), which show that bone modulus correlates relatively well with bone strength and hardness.”
Neustadt, J. O., & Pieczenik, S. R. (2012) · Cited by 1
Fritton, J. C., & Schaffler, M. B. (2008) · Elsevier eBooks · doi:10.1016/b978-012370544-0.50026-4 · Cited by 9
Self-citationPalomares, K. T. S., & Cullinane, D. M. (2004) · CRC Press eBooks · doi:10.1201/9780203495094.ch10 · Cited by 1
High-resolution local trabecular strain within trabecular structure under cyclic loading
Amraish, N., & Pahr, D. H. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106318 · Cited by 2
Kim, S.-W., & Jeong, H.-Y. (2024) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-024-01122-4 · Cited by 1
“For instance, Fyhrie and Schaffler performed compression tests on human vertebral cancellous bone specimens over the failure strain of 0.15, revealing a strong correlation between the ultimate strength and the tissue stiffness [16].”
InfluentialForni, R., Bruno, D. G., Palanca, M., Cristofolini, L., & Gargiulo, P. (2024) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine62247.2024.10797161 · Cited by 1
“The load/unload cycle reported in this work is comparable with the shape reported in previous studies on cancellaneous bone [23].”
Kinney, J. H., & Stolken, J. S. (2004) · Bone · doi:10.1016/j.bone.2004.01.017 · Cited by 1
Trabecular Microarchitecture, Endplate Failure, and the Biomechanics of Human Vertebral Fractures
Fields, A. J. (2010) · eScholarship (California Digital Library) · Cited by 2
Micromechanics of Human Bone: Role of Architecture and Tissue Material Properties
Sadoughi, S. (2019) · eScholarship (California Digital Library) · Cited by 3
Sandmann, F. (2011) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-1107
Articles, A., O’Brien, F. J., Harley, B. A. C., & Yannas, I. V. (2010)
Abdollahi, A. A., Xiao, Y., & Qin, Q. (2013) · ANU Open Research (Australian National University)
Bone Strength Multi-axial Behavior - Volume Fraction, Anisotropy and Microarchitecture
Sanyal, A. (2013) · eScholarship (California Digital Library)
Metadata
- Authors
- Fyhrie, D. P., & Schaffler, M. B.
- Affiliations
- Henry Ford Hospital (US)
- Corresponding author
- Fyhrie, D.P.
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 1994-01
- Volume
- 15
- Issue
- 1
- Pages
- 105-109
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2010182151
- Semantic Scholar
- 12a03303b6c3ce37c904a134aee527ccd89b13a6
- Cited by
- 215
- References
- 30
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 4 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 7 · 2018: 12 · 2017: 4 · 2016: 6 · 2015: 8 · 2014: 6 · 2013: 9 · 2012: 10
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Bone (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR41210, AR-40776)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- vertebral cancellous bone, trabecular bone, compressive failure, microcracking, shear stress, tissue stiffness, bone strength, residual strength, energy dissipation, trabecular bone microarchitecture
- MeSH terms
- Aged, Aged, 80 and over, Female, Humans, Lumbar Vertebrae, Male, Middle Aged, Stress, Mechanical, Thoracic Vertebrae, Fractures, Stress
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.