Inflammation, Wound Healing, and the Foreign-Body Response
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Toxic potential of materials at the nanolevel
Nel, A., Xia, T., Mädler, L., & Li, N. (2006) · Science · doi:10.1126/science.1114397 · Cited by 9,324
Hynes (2002) · doi:10.1016/s0092-8674(02)00971-6 · Cited by 8,606
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Self-citationThe Basic Science of Wound Healing
Broughton, G., Janis, J. E., & Attinger, C. E. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000225430.42531.c2 · Cited by 1,519
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Self-citationThe Evolution of Cell Adhesion
Hynes, R. O., & Zhao, Q. (2000) · The Journal of Cell Biology · doi:10.1083/jcb.150.2.f89 · Cited by 487
Jones, J. A., Chang, D. T., Meyerson, H., Colton, E., Kwon, I. K., Matsuda, T., & Anderson, J. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31221 · Cited by 352
Self-citationThe Hemostatic System as a Regulator of Angiogenesis
Browder, T., Folkman, J., & Pirie-Shepherd, S. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.275.3.1521 · Cited by 316
(1995) · Europe PMC (PubMed Central) · Cited by 294
Self-citationHenson, P. M. (1971) · PubMed · Cited by 250
Cited by
Brown, B. N., Londono, R., Tottey, S., Zhang, L., Kukla, K. A., Wolf, M. T., Daly, K. A., Reing, J. E., & Badylak, S. F. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.031 · Cited by 745
Hiromoto, S., Inoue, M., Taguchi, T., Yamane, M., & Ohtsu, N. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.09.026 · Cited by 201
“In the case of OCP- and HAp-AZ31, the acute inflammation reaction also took place and was presumably calmed down in several days [48] before the initiation of apparent corrosion, leading to the less formation of fibrous tissue layer.”
BackgroundBiocompatibility Issues with Modern Implants in Bone - A Review for Clinical Orthopedics
Nuss, K. M. R., & Rechenberg, B. V. (2008) · The Open Orthopaedics Journal · doi:10.2174/1874325000802010066 · Cited by 175
The Electrode‐Tissue Interface: The Revolutionary Role of Steroid Elution
MONO, H. G., & STOKES, K. B. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02905.x · Cited by 151
Biocompatibility and remodeling potential of pure arterial elastin and collagen scaffolds
Simionescu, D. T., Lu, Q., Song, Y. Q., Lee, J., Rosenbalm, T. N., Kelley, C., & Vyavahare, N. R. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.013 · Cited by 124
Biomaterials, Biomechanics, Tissue Healing, and Immediate-Function Dental Implants
Lemons, J. E. (2004) · Journal of Oral Implantology · doi:10.1563/0712.1 · Cited by 112
Nanopatterned bulk metallic glass-based biomaterials modulate macrophage polarization
Shayan, M., Padmanabhan, J., Morris, A. H., Cheung, B., Smith, R., Schroers, J., & Kyriakides, T. R. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.05.051 · Cited by 75
Etiology and Measurement of Peri-Implant Crestal Bone Loss (CBL)
Naveau, A., Shinmyouzu, K., Moore, C., Avivi‐Arber, L., Jokerst, J. V., & Koka, S. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020166 · Cited by 82
“This condition is considered aseptic since its initiation does not involve the oral microbiota however, this does not rule out the possibility of a secondary bacterial infection or a bacterial-derived marginal bone resorption in individual cases [4,22,26,27,29,34,35,47,48].”
BackgroundPitenis, A. A., Urueña, J. M., Hart, S. M., O’Bryan, C. S., Marshall, S. L., Levings, P. P., Angelini, T. E., & Sawyer, W. G. (2018) · Tribology Letters · doi:10.1007/s11249-018-1029-7 · Cited by 77
ten Brink, T., Damanik, F., Rotmans, J. I., & Moroni, L. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202301939 · Cited by 71
Subbiahdoss, G., Fernández, I. C. S., Domingues, J. D. S., Kuijer, R., van der Mei, H. C., & Busscher, H. J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024827 · Cited by 69
Fundamentals of protein and cell interactions in biomaterials
Felgueiras, H. P., Antunes, J. C., Martins, M. C. L., & Barbosa, M. A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100803-4.00001-2 · Cited by 78
MITRA, S. P. (2020) · Journal of Surface Science and Technology · doi:10.18311/jsst/2020/23282 · Cited by 79
Ion, R., Necula, M. G., Mazare, A., Mitran, V., Neacsu, P., Schmuki, P., & Cîmpean, A. (2019) · Current Medicinal Chemistry · doi:10.2174/0929867326666190726123229 · Cited by 42
The challenge of biocompatibility evaluation of biocomposites
Iqbal, H. M. N., & Keshavarz, T. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100752-5.00014-7 · Cited by 50
Boccafoschi, F., Mosca, C., & Cannas, M. F. (2012) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1526 · Cited by 40
“Clinically, these activities lead to biomaterial degradation, fibrous encapsulation and eventually device failure (Anderson, 2004; Anderson et al., 2004).”
BackgroundDewey, M. J., Milner, D. J., Weisgerber, D. W., Flanagan, C. L., Rubessa, M., Lotti, S., Polkoff, K. M., Crotts, S. J., Hollister, S. J., Wheeler, M. B., et al. (2021) · Biofabrication · doi:10.1088/1758-5090/ac30d5 · Cited by 52
“Due to the large size of bone missing, this makes bacterial infection more likely, as well as persistent inflammation, and a biomaterial that can prevent infection and guide the immune response towards repair should lead to more successful bone repair [14, 15, 55].”
Cell Attachment to Hydrogel-Electrospun Fiber Mat Composite Materials
Han, N., Johnson, J. K., Bradley, P. A., Parikh, K. S., Lannutti, J. J., & Winter, J. O. (2012) · Journal of Functional Biomaterials · doi:10.3390/jfb3030497 · Cited by 35
“Resistance to cell attachment can be an important modulator of this behavior [17–19].”
BackgroundLustig, A., Alves, P. J. P., Call, E., Santamaria, N., & Gefen, A. (2020) · International Wound Journal · doi:10.1111/iwj.13515 · Cited by 37
On marginal bone level changes around dental implants
Coli, P., & Jemt, T. (2021) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12970 · Cited by 42
Antifouling surfaces in medical application
Utrata‐Wesołek, A. (2013) · Polimery · doi:10.14314/polimery.2013.685 · Cited by 36
Domingues, J. D. S., Roest, S., Wang, Y., van der Mei, H. C., Libera, M., van Kooten, T. G., & Busscher, H. J. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.02.028 · Cited by 37
Sowa, M., & Simka, W. (2018) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2018.03.013 · Cited by 33
An autonomous implantable device for the prevention of death from opioid overdose
Ciatti, J. L., Vázquez‐Guardado, A., Brings, V. E., Park, J., Ruyle, B. C., Ober, R. A., McLuckie, A. J., Talcott, M., Carter, E. A., Burrell, A. R., et al. (2024) · Science Advances · doi:10.1126/sciadv.adr3567 · Cited by 35
“A small-scale DC motor drives the injection of NLX into the adjacent subcutaneous tissue, puncturing any fibrotic capsule that may form around the device as a foreign body response ( 45 ).”
Immune‐Modulating Mucin Hydrogel Microdroplets for the Encapsulation of Cell and Microtissue
Yan, H., Melin, M., Jiang, K., Trossbach, M., Badadamath, B., Langer, K., Winkeljann, B., Lieleg, O., Hong, J., Joensson, H. N., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202105967 · Cited by 31
Closer to nature: new biomaterials and tissue engineering in ophthalmology
Allan, B. D. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.11.1235 · Cited by 30
Polymeric Biomaterials for Implantable Prostheses
Dang, T. T., Nikkhah, M., Memić, A., & Khademhosseini, A. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-396983-5.00020-x · Cited by 42
Dahe, G. J., Kadam, S. S., Sabale, S. S., Kadam, D. P., Sarkate, L. B., & Bellare, J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0025236 · Cited by 28
Champeau, M., Coutinho, I. T., Thomassin, J., Tassaing, T., & Jérôme, C. (2019) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2019.101468 · Cited by 29
Waldeck, H., Wang, X., Joyce, E., & Kao, W. J. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.09.044 · Cited by 25
“Along with polymorphonuclear leukocytes (PMNs), these phagocytes are among the first responders to a site of injury where they act to clear away debris and defend against bacterial infiltration [3,4].”
The performance of gelling fibre wound dressings under clinically relevant robotic laboratory tests
Lustig, A., & Gefen, A. (2022) · International Wound Journal · doi:10.1111/iwj.13761 · Cited by 25
Biointerface: protein enhanced stem cells binding to implant surface
Chrzanowski, W., Kondyurin, A. V., Lee, J. H., Lord, M. S., Bilek, M., & Kim, H. (2012) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-012-4687-2 · Cited by 25
Høl, P. J., Gjerdet, N. R., & Jonung, T. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.02.001 · Cited by 23
“All corrosion processes may cause release of metal ions and result in sensitization and local inflammation (Anderson, 2004; BaskoPlluska et al., 2011).”
BackgroundVoskerician, G., Liu, C.-C., & Anderson, J. M. (2005) · IEEE Sensors Journal · doi:10.1109/jsen.2005.857877 · Cited by 26
Self-citationIn vivo fluorescence imaging of apoptosis during foreign body response
Bartsch, I., Willbold, E., Yarmolenko, S. N., & Witte, F. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.039 · Cited by 22
“The foreign body reaction (FBR) is a mandatory, very complex and dynamic inflammatory process resulting from the immunological reactions originating both from injured tissues and the presence of a grafted biomaterial or an implant [1].”
BackgroundDevelopment of humic acid and alginate-based wound dressing and evaluation on inflammation
Yalman, V., & Laçin, N. T. (2019) · Materials Technology · doi:10.1080/10667857.2019.1619961 · Cited by 20
“and the inflammatory phase follows [6,7].”
Thromboelastometric and platelet responses to silk biomaterials
Kundu, B., Schlimp, C., Nürnberger, S., Redl, H., & Kundu, S. (2014) · Scientific Reports · doi:10.1038/srep04945 · Cited by 17
Lustig, A., & Gefen, A. (2021) · International Wound Journal · doi:10.1111/iwj.13631 · Cited by 15
Functionalization of Silicone Surface with Drugs and Polymers for Regulation of Capsular Contracture
Faruq, O., Chien, P. N., Dönmez, N., Nam, S., & Heo, C. Y. (2021) · Polymers · doi:10.3390/polym13162731 · Cited by 16
“The mononuclear cells secrete IL-8, IL-18, IL-4, IL-7, IL-10, and other cytokines (Figure 3) [36,37].”
BackgroundPhagocytosis of Bacteria Adhering to a Biomaterial Surface in a Surface Thermodynamic Perspective
Domingues, J. D. S., van der Mei, H. C., Busscher, H. J., & van Kooten, T. G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070046 · Cited by 19
“Although neutrophils are crucial in the first hours of host response to an infection, they disappear within a day [13,14].”
The role of Toll-like receptor signaling in the macrophage response to implanted materials
McKiel, L. A., Woodhouse, K. A., & Fitzpatrick, L. E. (2020) · MRS Communications · doi:10.1557/mrc.2019.154 · Cited by 18
Tissue adhesives and sealants for surgical applications
Jarrett, P. K., & Coury, A. J. (2013) · Elsevier eBooks · doi:10.1533/9780857096425.4.449 · Cited by 13
Implantable Electrodes with Carbon Nanotube Coatings
Minnikanti, S., & Peixoto, N. (2011) · InTech eBooks · doi:10.5772/17980 · Cited by 14
McShane, M. J. (2007) · Springer eBooks · doi:10.1007/0-387-33015-1_6 · Cited by 13
Aramwit, P. (2014) · Elsevier eBooks · doi:10.1533/9780857097064.2.299 · Cited by 15
Macrophage proinflammatory response to the titanium alloy equipment in dental implantation
Chen, X., Li, H. S., Yin, Y., Feng, Y., & Tan, X. W. (2015) · Genetics and Molecular Research · doi:10.4238/2015.august.7.25 · Cited by 12
“MCP-1 can attract monocytes to infiltrate tissue through chemotaxis and plays an important role in macrophage accumulation in the damaged area (Anderson, 2004; Refai et al., 2004).”
BackgroundCompetitive Adsorption of Three Human Plasma Proteins onto Sulfhydryl-to-sulfonate Gradient Surfaces
Ding, Y.-X., & Hlady, V. (2011) · Croatica Chemica Acta · doi:10.5562/cca1821 · Cited by 11
Determining the Biological Properties of Biomaterials In Vivo
Vasiljevic, P. J., Živković, J. M., Vukelić-Nikolić, M. Đ., & Najman, S. J. (2017) · Springer eBooks · doi:10.1007/978-3-319-68025-5_17 · Cited by 12
Image-Based Evaluation of In Vivo Degradation for Shape-Memory Polymer Polyurethane Foam
Graul, L. M., Horn, S. J., Nash, L. D., Cheung, T. B., Clubb, F. J., & Maitland, D. J. (2022) · Polymers · doi:10.3390/polym14194122 · Cited by 10
Vasconcelos, F., Reis, R. L., Martins, A. M., & Neves, N. M. (2022) · Springer eBooks · doi:10.1007/978-3-030-99958-2_10 · Cited by 10
Ricciardi, G., Siracusano, L., Micale, E., Addorisio, V., Ballato, M., Donadio, D., Tralongo, P., Giuffrè, G., Leonetti, D., Martini, M., et al. (2025) · Applied Sciences · doi:10.3390/app15169156 · Cited by 14
Mardina, Z., Venezuela, J., Sjafrizal, T., Shi, Z., Dargusch, M. S., & Atrens, A. (2023) · Materials Today Communications · doi:10.1016/j.mtcomm.2023.105809 · Cited by 10
Momtaz, S., Abdolghaffari, A., Jasemi, E., Yaghoobvand, B., Esmaeilzadeh, S., Abdollahi, A., & Abdollahi, M. R. (2021) · Journal of Medicinal Plants · doi:10.52547/jmp.20.77.37 · Cited by 7
Bridging the Gap Between In Vitro and In Vivo Evaluation of Biomaterial-Associated Infections
Subbiahdoss, G., Domingues, J. D. S., Kuijer, R., van der Mei, H. C., & Busscher, H. J. (2012) · Springer eBooks · doi:10.1007/978-1-4614-1031-7_5 · Cited by 7
Bone Reaction to a Newly Developed Fiber-reinforced Composite Material for Craniofacial Implants
Moldovan, M. A., Boşca, A. B., Roman, R. C., Prejmerean, C., Prodan, D., Béré, P., Cosma, C., & Rotaru, H. (2019) · Materiale Plastice · doi:10.37358/mp.20.2.5359 · Cited by 6
Quercetin as therapeutic modality for inflammatory diseases: Where we are and where to go?
Gupta, M., Ahmad, J., SAHOO, M. R., Waiwut, P., & Mishra, A. (2025) · Food Bioscience · doi:10.1016/j.fbio.2025.108149 · Cited by 9
Assessment of the Anti-Thrombogenic Activity of Polyurethane Starch Composites
Cespedes, J. F., Arévalo-Alquichire, S., Díaz, L. E., & Valero, M. F. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13040184 · Cited by 5
“Furthermore, the activation of the complement and immunology systems has been connected to the inflammation response by the activation of neutrophils and macrophages that, in the presence of non-degradable implants, produce granulomas to phagocyte the biomaterial, inducing chronic inflammation [10].”
BackgroundBiocompatibility of Microsystems
Singh, T., Rühe, J., & Biesalski, M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.00523-3 · Cited by 5
Ogbanya, K. C., Eze, C. A., & Shoyinka, S. V. O. (2013) · Comparative Clinical Pathology · doi:10.1007/s00580-013-1823-4 · Cited by 2
“This is a usual phenomenon which occurs in response to foreign body implant and is characterized by a reduction in inflammatory response (Adoroson 2004).”
BackgroundCharacterisation of debris from laser and mechanical cutting of bone
Rachmanis, N., McGuinness, G. B., & McGeough, J. A. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914541089 · Cited by 2
“In general, particles with length scales above 5 mm are not phagocytosed by macrophages, and so the majority of the particulate debris generated by all methods would have the potential to induce frustrated phagocytosis in vivo if not removed during the surgical procedure.(13) The sagittal saw produced the highest perc…”
ResultMacrophage-mediated phagocytosis of bacteria adhering on biomaterial surfaces
Domingues, J. D. S. (2014) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 4
Raţiu, C. A., Dejeu, D., Croitoru, C. A., Todor, A., Rațiu, I. A., Luca, R. E., Moisa, C., Miclaus, V., & Vasile Florin, R. U. S. (2025) · Medicina · doi:10.3390/medicina62010072 · Cited by 1
Implantable Cardioverter Defibrillators
Baura, G. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-374976-5.00005-0
Sylvester, M. L. (2013) · ResearchWorks at the University of Washington (University of Washington)
Pengaruh Desain Stent pada Jumlah Limfosit dan Trombosit Kelinci (Oryctolagus Cuniculus)
Siswomihardjo, W., Widyasrini, D. A., Arifianto, D., Budhi, S., & Taufiq, N. (2019) · Jurnal Teknosains · doi:10.22146/teknosains.51526
Bolle, E. C. L. (2019) · Queensland University of Technology · doi:10.5204/thesis.eprints.136414
Tissue Wound Healing in the Presence of Implants
Bizios, R., & Wechsler, M. (2024) · Wiley eBooks · doi:10.1002/9781394300013.ch5
Metadata
- Authors
- Anderson, J. M.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Anderson, James M.
- ORCID
- Anderson, James M.
- Venue
- Biomaterials Science
- Publisher
- Elsevier
- Published
- 2013
- Pages
- 503-512
- OpenAlex
- W2490892400
- Cited by
- 69
- References
- 24
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 6 · 2020: 2 · 2019: 9 · 2018: 3 · 2017: 3 · 2016: 1 · 2015: 3 · 2014: 6 · 2013: 6
- FWCI
- 31.89
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Elsevier eBooks (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Wound Healing and Treatments
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- inflammation, wound healing, foreign body reaction, biomaterials, biocompatibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.