Abstract
The electrode-tissue interface is that area lying between the cathode of a low-voltage implantable pacemaker or cardioverter-defibrillator (ICD) lead and the endocardium or epi-myocardium of the cardiac chamber being paced. The electrical stimulus that is delivered to this interface is responsible for myocyte depolarization with consequent cardiac contraction. The process by which this occurs is reasonably well understood and any explanation requires a basic understanding of the physics and cellular electrophysiology of pacing. The effective and efficient delivery of electrical energy to the myocardium via the lead is dependent on many factors to be discussed in this review. However, despite numerous evolutionary changes occurring in the cathode's material, design, and surface configuration, it was not until the incorporation of steroid-elution to the electrode-tissue interface that reliable and significantly low stimulation threshold cardiac pacing became possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Some aspects of macrophage behavior at the implant interface
Salthouse, T. N. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180407 · Cited by 176
Inflammation, Wound Healing, and the Foreign-Body Response
Anderson, J. M. (2013) · Biomaterials Science · doi:10.1016/b978-0-08-087780-8.00044-9 · Cited by 69
Cited by
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
Feiner, R., Engel, L., Fleischer, S., Malki, M., Gal, I., Shapira, A., Shacham-Diamand, Y., & Dvir, T. (2016) · Nature Materials · doi:10.1038/nmat4590 · Cited by 460
A transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy
Choi, Y. S., Jeong, H., Yin, R. T., Avila, R., Pfenniger, A., Yoo, J., Lee, J. Y., Tzavelis, A., Lee, Y. J., Chen, S. W., et al. (2022) · Science · doi:10.1126/science.abm1703 · Cited by 267
Cohen, M. I., Bush, D. M., Vetter, V. L., Tanel, R. E., Wieand, T. S., Gaynor, J. W., & Rhodes, L. A. (2001) · Circulation · doi:10.1161/01.cir.103.21.2585 · Cited by 213
Prevention of the foreign body response to implantable medical devices by inflammasome inhibition
Barone, D. G., Carnicer-Lombarte, A., Tourlomousis, P., Hamilton, R. S., Prater, M., Rutz, A. L., Dimov, I. B., Malliaras, G. G., Lacour, S. P., Robertson, A. A. B., et al. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2115857119 · Cited by 67
Metadata
- Authors
- MONO, H. G., & STOKES, K. B.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 15
- Issue
- 1
- Pages
- 95-107
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2139754920
- Cited by
- 151
- References
- 3
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Electrode‐Tissue Interface: The Revolutionary Role of Steroid Elution. https://app.cochat.ai/papers/10.1111/j.1540-8159.1992.tb02905.x
- The paper
- MONO, H. G., & STOKES, K. B. (1992). The Electrode‐Tissue Interface: The Revolutionary Role of Steroid Elution. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1992.tb02905.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.