Mechanical Properties of Tissue
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Report of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Tables of Physical and Chemical Constants
(1997) · Zeitschrift für Kristallographie - Crystalline Materials · doi:10.1524/zkri.1997.212.5.400 · Cited by 955
The dynamic elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006687 · Cited by 904
Density and composition of mammalian muscle
Méndez, J., & Keys, A. (1960) · Metabolism · Cited by 802
The composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764
Cited by
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
MR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Marshall, G. W., Balooch, M., Gallagher, R. R., Gansky, S. A., & Marshall, S. J. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1<87::aid-jbm10>3.0.co;2-z · Cited by 379
Photoacoustic imaging and temperature measurement for photothermal cancer therapy
Shah, J., Park, S., Aglyamov, S., Larson, T., Ma, L., Sokolov, K., Johnston, K., Milner, T., & Emelianov, S. Y. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2940362 · Cited by 354
Garcia, P. A., Davalos, R. V., & Miklavcic, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103083 · Cited by 174
Material ejection in nanosecond Er:YAG laser ablation of water, liver, and skin
Apitz, I., & Vogel, A. (2005) · Applied Physics A · doi:10.1007/s00339-005-3213-5 · Cited by 170
Photoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser
Maslov, K., & Wang, L. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904965 · Cited by 168
Metadata
- Authors
- Duck, F. A.
- Venue
- Physical Properties of Tissues
- Publisher
- Elsevier
- Published
- 1990
- Pages
- 137-165
- OpenAlex
- W2487347500
- Cited by
- 175
- References
- 49
- FWCI
- 0.00
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.