The DOI matches its Crossref record.
The composition of body tissues
Abstract
A reassessment of the composition data given by ICRP (1975) has been completed, augmented with results from appropriate recent studies. The water, lipid, protein, carbohydrate and ash contents, together with elemental compositions, mass and electron densities are given here for 56 body tissues. Seven tissues (adipose tissue, heart, kidney, liver, mammary gland, muscle--skeletal and skin) had sufficient measured data to enable the spread in the results to be evaluated. All the compositions presented apply to healthy, adult humans, except for some new material on the bones of children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Matcher, S. J., Cope, M., & Delpy, D. T. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/011 · Cited by 323
Choe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Metadata
- Authors
- Woodard, H. Q., & White, D. R.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1986-12
- Volume
- 59
- Issue
- 708
- Pages
- 1209-1218
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2139684042
- Cited by
- 764
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The composition of body tissues. https://app.cochat.ai/papers/10.1259/0007-1285-59-708-1209
- The paper
- Woodard, H. Q., & White, D. R. (1986). The composition of body tissues. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-59-708-1209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.