Microfluidics for Synthetic Biology
Open accessThe DOI matches its Crossref record.
Abstract
With the expanding interest in cellular responses to dynamic environments, microfluidic devices have become important experimental platforms for biological research. Microfluidic “microchemostat” devices enable precise environmental control while capturing high quality, single-cell gene expression data. For studies of population heterogeneity and gene expression noise, these abilities are crucial. Here, we describe the necessary steps for experimental microfluidics using devices created in our lab as examples. First, we discuss the rational design of microchemostats and the tools available to predict their performance. We carefully analyze the critical parts of an example device, focusing on the most important part of any microchemostat: the cell trap. Next, we present a method for generating on-chip dynamic environments using an integrated fluidic junction coupled to linear actuators. Our system relies on the simple modulation of hydrostatic pressure to alter the mixing ratio between two source reservoirs and we detail the software and hardware behind it. To expand the throughput of microchemostat experiments, we describe how to build larger, parallel versions of simpler devices. To analyze the large amounts of data, we discuss methods for automated cell tracking, focusing on the special problems presented by Saccharomyces cerevisiae cells. The manufacturing of microchemostats is described in complete detail: from the photolithographic processing of the wafer to the final bonding of the PDMS chip to glass coverslip. Finally, the procedures for conducting Escherichia coli and S. cerevisiae microchemostat experiments are addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A sensing array of radically coupled genetic ‘biopixels’
Prindle, A., Samayoa, P., Razinkov, I., Danino, T., Tsimring, L. S., & Hasty, J. (2012) · Nature · doi:10.1038/nature10722 · Cited by 397
Self-citationEmergent genetic oscillations in a synthetic microbial consortium
Chen, Y., Kim, J. K., Hirning, A. J., Josić, K., & Bennett, M. R. (2015) · Science · doi:10.1126/science.aaa3794 · Cited by 278
Interplay between gene expression noise and regulatory network architecture
Chalancon, G., Ravarani, C. N. J., Balaji, S., Martinez-Arias, A., Aravind, L., Jothi, R., & Babu, M. M. (2012) · Trends in Genetics · doi:10.1016/j.tig.2012.01.006 · Cited by 268
Agent-based modelling in synthetic biology
Gorochowski, T. E. (2016) · Essays in Biochemistry · doi:10.1042/ebc20160037 · Cited by 86
“The use of microfluidics to study single-cell dynamics has seen significant growth in synthetic biology [73].”
BackgroundVacuum-assisted cell loading enables shear-free mammalian microfluidic culture
Kolnik, M., Tsimring, L. S., & Hasty, J. (2012) · Lab on a Chip · doi:10.1039/c2lc40569e · Cited by 86
Self-citation
Metadata
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidics for Synthetic Biology. https://app.cochat.ai/papers/10.1016/b978-0-12-385075-1.00014-7
- The paper
- Ferry, M. S., Razinkov, I. A., & Hasty, J. (2011). Microfluidics for Synthetic Biology. Methods in Enzymology. https://doi.org/10.1016/b978-0-12-385075-1.00014-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.