Imaging Intracellular Protein Dynamics by Spinning Disk Confocal Microscopy
Open accessThe DOI matches its Crossref record.
Abstract
The palette of fluorescent proteins has grown exponentially over the last decade, and as a result live imaging of cells expressing fluorescently tagged proteins is becoming more and more main stream. Spinning disk confocal microscopy (SDC) is a high speed optical sectioning technique, and a method of choice to observe and analyze intracellular fluorescent protein dynamics at high spatial and temporal resolution. In an SDC system, a rapidly rotating pinhole disk generates thousands of points of light that scan the specimen simultaneously, which allows direct capture of the confocal image with low noise scientific grade cooled charged-coupled device (CCD) cameras, and can achieve frame rates of up 1000 frames per second. In this chapter we describe important components of a state-of-the-art spinning disk system optimized for live cell microscopy, and provide a rationale for specific design choices. We also give guidelines how other imaging techniques such as total internal reflection (TIRF) microscopy or spatially controlled photoactivation can be coupled with SDC imaging, and provide a short protocol on how to generate cell lines stably expressing fluorescently tagged proteins by lentivirus-mediated transduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comprehensive analysis of normal adjacent to tumor transcriptomes
Aran, D., Camarda, R., Odegaard, J., Paik, H., Oskotsky, B., Krings, G., Goga, A., Sirota, M., & Butte, A. J. (2017) · Nature Communications · doi:10.1038/s41467-017-01027-z · Cited by 617
Fluorescence live cell imaging
Ettinger, A., & Wittmann, T. (2014) · Methods in Cell Biology · doi:10.1016/b978-0-12-420138-5.00005-7 · Cited by 334
Self-citationSingle Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Stehbens, S. J., Paszek, M., Pemble, H., Ettinger, A., Gierke, S., & Wittmann, T. (2014) · Nature Cell Biology · doi:10.1038/ncb2975 · Cited by 245
Self-citationOptical coherence tomography in biofilm research: A comprehensive review
Wagner, M., & Horn, H. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26283 · Cited by 211
Neurotoxic microglia promote TDP-43 proteinopathy in progranulin deficiency
Zhang, J., Velmeshev, D., Hashimoto, K., Huang, Y.-H., Hofmann, J. W., Shi, X., Chen, J., Leidal, A. M., Dishart, J. G., Cahill, M. K., et al. (2020) · Nature · doi:10.1038/s41586-020-2709-7 · Cited by 191
Self-citationPresent Application and Perspectives of Organoid Imaging Technology
Fei, K., Zhang, J., Yuan, J., & Xiao, P. (2022) · Bioengineering · doi:10.3390/bioengineering9030121 · Cited by 65
Doublecortin Is Excluded from Growing Microtubule Ends and Recognizes the GDP-Microtubule Lattice
Ettinger, A., van Haren, J., Ribeiro, S. A., & Wittmann, T. (2016) · Current Biology · doi:10.1016/j.cub.2016.04.020 · Cited by 55
Self-citationShi, M., Calaruso, P., & Mody, C. H. (2012) · Cellular Microbiology · doi:10.1111/cmi.12027 · Cited by 32
Metadata
- Authors
- Stehbens, S., Pemble, H., Murrow, L., & Wittmann, T.
- Venue
- Methods in Enzymology
- Publisher
- Elsevier
- Published
- 2012
- Volume
- 504
- Pages
- 293-313
- ISSN
- 0076-6879 (ISSN-L)
- OpenAlex
- W1493008526
- Cited by
- 104
- References
- 0
- FWCI
- 9.33
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.