The DOI matches its Crossref record; 582 of the 582 references it cites were found in a registry or an index.
Single Cell Optical Imaging and Spectroscopy
Open accessAbstract
In his 1665 treatise, Micrographia, Robert Hooke described the many observations he had made using a microscope, including compartment-like structures in cork samples that he termed “cells”
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Non-blinking semiconductor nanocrystals
Wang, X., Ren, X., Kahen, K., Hahn, M. A., Rajeswaran, M., Maccagnano-Zacher, S., Silcox, J., Cragg, G. E., Efros, A. L., & Krauss, T. D. (2009) · Nature · doi:10.1038/nature08072 · Cited by 612
RetractedPrinciples of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen
Mie, G. (1908) · Annalen der Physik · doi:10.1002/andp.19083300302 · Cited by 11,537
Kelly, K. L., Coronado, E., Zhao, L. L., & Schatz, G. C. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp026731y · Cited by 10,594
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Semiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M., Moronne, M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,613
Cited by
Highly emissive platinum(II) metallacages
Yan, X., Cook, T. R., Wang, P., Huang, F., & Stang, P. J. (2015) · Nature Chemistry · doi:10.1038/nchem.2201 · Cited by 678
Yang, Z., Albrow-Owen, T., Cui, H., Alexander-Webber, J., Gu, F., Wang, X., Wu, T.-C., Zhuge, M., Williams, C., Wang, P., et al. (2019) · Science · doi:10.1126/science.aax8814 · Cited by 608
Ni, X.-L., Chen, S., Yang, Y., & Tao, Z. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b01223 · Cited by 328
Li, Q., Zhuo, X., Li, S., Ruan, Q., Xu, Q., & Wang, J. (2015) · Advanced Optical Materials · doi:10.1002/adom.201400505 · Cited by 279
Phosphine Oxides Manipulate Aggregation‐Induced Delayed Fluorescence for Time‐Resolved Bioimaging
Zhao, B., Wang, H., Xie, M., Han, C., Yang, H., Zhao, W., Zhao, Q., & Xu, H. (2021) · Advanced Photonics Research · doi:10.1002/adpr.202000096 · Cited by 12
Metadata
- Authors
- Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., Huang, B., & Fang, N.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-14
- Volume
- 113
- Issue
- 4
- Pages
- 2469-2527
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W1987248422
- Cited by
- 292
- References
- 582
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single Cell Optical Imaging and Spectroscopy. https://app.cochat.ai/papers/10.1021/cr300336e
- The paper
- Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., Huang, B., & Fang, N. (2013). Single Cell Optical Imaging and Spectroscopy. Chemical Reviews. https://doi.org/10.1021/cr300336e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.