EEG source localization
Open accessThe DOI matches its Crossref record; 150 of the 152 references it cites were found in a registry or an index.
Abstract
Since the discovery of electroencephalography (EEG), when it was hoped that EEG would offer "a window into the brain," researchers and clinicians have attempted to localize the neuronal activity in the brain that generates the scalp potentials measured noninvasively with EEG. Early explorations in the 1950s using electric field theory to infer the location and orientation of the current dipole in the brain from the scalp potential distribution triggered considerable efforts to quantitatively deduce these sources. Initially, dipole fitting, or dipole localization, was the method of choice and many studies used this approach in experimental and clinical studies with remarkable success. Later on, new methods were proposed that attempted to overcome the problem of having to fix the number of sources a priori; these methods are known as distributed source imaging techniques. The introduction and increasing availability of magnetic resonance imaging, allowing detailed realistic anatomy of the brain and head to be incorporated in source localization methods, has drastically increased the precision of such approaches. Today, source localization of EEG (and magnetoencephalography, or MEG) has reached a level of consistency and precision that allows these methods to be placed in the family of brain imaging techniques. The particular advantage that they have over other imaging methods is their high temporal resolution, which allows the origin of activity to be distinguished from its propagation and information flow in large-scale brain networks to be examined. This chapter gives an overview of these methods and illustrates them with several examples, thereby focusing on EEG source imaging in epilepsy and presurgical planning, as clinical applications with remarkable maturation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Those studies are likely to suffer from substantial data leakage, since physiological sources of electrical activity appear redundantly across multiple EEG scalp electrodes (Michel and He, 2019).”
From Data leakage in deep learning studies of translational EEG (2024) · cites this paper as Michel and He, 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strogatz, S. H. (2001) · Nature · doi:10.1038/35065725 · Cited by 8,302 · cited 1×
“…of interactions using effective connectivity measures in the framework of Wiener – Granger causality or dynamic causal modeling (Urbano et al., 1998; Strogatz, 2001; Brovelli et al., 2004; David et al., 2006; Lin et al., 2009; Martino et al., 2011; Porcaro et al., 2013; Plomp et al., 2014).”
MethodStandardized low-resolution brain electromagnetic tomography (sLORETA): technical details.
Pascual-Marqui, R. D. (2002) · PubMed · Cited by 4,070
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Self-citationDale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003 · cited 2×
“Dale and Sereno (1993) proposed the cortical current density model in which the dipoles are constrained to the directions perpendicular to the cortical surface.”
BackgroundInterpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Mitzdorf, U. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.37 · Cited by 1,673 · cited 1×
“It is generally understood that the main generators of the electroencephalograph (EEG) are the postsynaptic potentials that take place on the pyramidal cortical neurons (Mitzdorf, 1985; Lopes da Silva, 1991).”
BackgroundMichel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655 · cited 2×
“Such new models must be rigorously validated, leading to the legitimate question of the gold standard for validation (Michel et al., 2004b).”
BackgroundSelf-citationOjemann, G., Ojemann, J., Lettich, E., & Berger, M. (1989) · Journal of Neurosurgery · doi:10.3171/jns.1989.71.3.0316 · Cited by 1,489 · cited 4×
“Various efforts have been made to expand the limits of resective brain surgery with intraoperative mapping of functions such as motor or language through direct cortical stimulation (DCS) (Ojemann et al., 1989; Duffau et al., 2003), or intraoperative imaging with low field MRI and tractography (Prabhu et al., 2011; Se…”
BackgroundInfluential
Cited by
Interbrain synchrony: on wavy ground
Holroyd, C. B. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.02.002 · Cited by 148
“For example, EEG-based gamma IBS has been observed to occur 2-3 s after the eliciting stimulus [40], long after the signals should lose coherence between brains; when participants make eye-contact [98], which would be expected to elicit artifact; and in deep neural sources such as anterior cingulate cortex [92], despi…”
BackgroundData leakage in deep learning studies of translational EEG
Brookshire, G., Kasper, J., Blauch, N. M., Wu, Y. C., Glatt, R., Merrill, D. A., Gerrol, S., Yoder, K. J., Quirk, C., & Lucero, C. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1373515 · Cited by 103
“Those studies are likely to suffer from substantial data leakage, since physiological sources of electrical activity appear redundantly across multiple EEG scalp electrodes (Michel and He, 2019).”
BackgroundMaking ERP research more transparent: Guidelines for preregistration
Paul, M., Govaart, G., & Schettino, A. (2021) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.02.016 · Cited by 71
Electroencephalography source localization
Eom, T. (2022) · Korean Journal of Pediatrics · doi:10.3345/cep.2022.00962 · Cited by 62
Richer, N., Bradford, J. C., & Ferris, D. P. (2024) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2024.105718 · Cited by 58
Tang, K. W. K., Jeong, J., Hsieh, J.-C., Yao, M., Ding, H. Q., Wang, W., Liu, X., Pyatnitskiy, I., He, W., Moscoso-Barrera, W. D., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-60181-x · Cited by 69
Decision‐making in stereotactic epilepsy surgery
Miller, K. J., & Fine, A. L. (2022) · Epilepsia · doi:10.1111/epi.17381 · Cited by 43
Bosch‐Bayard, J., Biscay, R., Fernández, T., Otero, G., Ricardo-Garcell, J., Aubert-Vázquez, E., Evans, A. C., & Harmony, T. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119035 · Cited by 39
EEG brain waves and alpha rhythms: Past, current and future direction
Pascucci, D., Menétrey, M. Q., Passarotto, E., Luo, J., Paramento, M., & Rubega, M. (2025) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2025.106288 · Cited by 43
“For this reason, effective connectivity models are often applied to ‘source ’ time series reconstructed from scalp recordings using techniques such as electrical source imaging (Michel and He, 2019).”
EEG Spatiotemporal Patterns Underlying Self-other Voice Discrimination
Iannotti, G. R., Orepić, P., Brunet, D., Koenig, T. W., Alcoba-Banqueri, S., Garín, D., Schaller, K., Blanke, O., & Michel, C. M. (2021) · Cerebral Cortex · doi:10.1093/cercor/bhab329 · Cited by 27
Self-citationRosen, D., Oh, Y., Chesebrough, C., Zhang, F., & Kounios, J. (2024) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2024.108824 · Cited by 36
“EEG source reconstruction can thus provide an accurate functional-neuroanatomical model of brain activity in “ source space ” that explains the “ sensor space ” data recorded on the scalp (Michel and He, 2019).”
BackgroundMethodAn in–vivo validation of ESI methods with focal sources
Pascarella, A., Mikulan, E., Sciacchitano, F., Sarasso, S., Rubino, A., Sartori, I., Cardinale, F., Zauli, F. M., Avanzini, P., Nobili, L., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120219 · Cited by 29
Kurkin, S., Smirnov, N. M., Николаевна, П. Е., Kabir, M. S., Martynova, O., Sysoeva, O., Portnova, G. V., & Hramov, A. E. (2022) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-022-00717-0 · Cited by 24
Li, W., Zhang, W., Jiang, Z., Zhou, T., Xu, S., & Zou, L. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.960784 · Cited by 20
“, 2020) and the non-parameterized method of distributed source model (Michel and He, 2019).”
MethodSamudra, N. P., Ranasinghe, K. G., Kirsch, H. E., Rankin, K. P., & Miller, B. L. (2023) · Journal of Alzheimer s Disease · doi:10.3233/jad-220983 · Cited by 20
“Source localization can be performed on both MEG and EEG waveforms to identify the source of the IED, using an individualized head model [94].”
Intracortical brain‐heart interplay: An EEG model source study of sympathovagal changes
Catrambone, V., Candia‐Rivera, D., & Valenza, G. (2024) · Human Brain Mapping · doi:10.1002/hbm.26677 · Cited by 20
EEG reveals brain network alterations in chronic aphasia during natural speech listening
Mehraram, R., Kries, J., Clercq, P. D., Vandermosten, M., & Francart, T. (2025) · Scientific Reports · doi:10.1038/s41598-025-86192-8 · Cited by 16
Information transmission velocity-based dynamic hierarchical brain networks
Jiang, L., Li, F., Chen, Z., Zhu, B., Yi, C., Li, Y., Zhang, T., Peng, Y., Si, Y., Cao, Z., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.119997 · Cited by 18
Zheng, H., Pan, L., & Li, T. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107305 · Cited by 17
Formica, C., Gjonaj, E., Bonanno, L., Quercia, A., Cartella, E., Romeo, L., Quartarone, A., Marino, S., & Salvo, S. D. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.03.026 · Cited by 20
Pitfalls in scalp EEG: Current obstacles and future directions
Greenblatt, A., Beniczky, S., & Nascimento, F. A. (2023) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2023.109500 · Cited by 18
Teng, C., Cong, L., Wang, W., Cheng, S., Wu, M., Dang, W., Jia, M., Ma, J., Xu, J., & Hu, W. (2024) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2024.1338765 · Cited by 17
“However, the accuracy of cortical source estimation is largely dependent on sensor density and the head model constructed by individual MRI (Song et al., 2015; Michel and He, 2019).”
BackgroundTen quick tips for clinical electroencephalographic (EEG) data acquisition and signal processing
Cisotto, G., & Chicco, D. (2024) · PeerJ Computer Science · doi:10.7717/peerj-cs.2256 · Cited by 13
“In some clinical applications, it might be useful to operate the so-called electrical source imaging ( He et al., 2011 ; Michel & He, 2019 ), a transformation aimed to map the electrical activity measured at the scalp level (by the EEG sensors) to a set of brain sources that might have produced…”
BackgroundElectroencephalography: electrode arrays in dogs
Everest, S., Gaitero, L., Dony, R., Linden, A. Z., Cortez, M. A., & James, F. (2024) · Frontiers in Veterinary Science · doi:10.3389/fvets.2024.1402546 · Cited by 17
Cortical activations induced by electrical versus vibrotactile finger stimulation using EEG
Alouit, A., Gavaret, M., Ramdani, C., Lindberg, P. G., & Dupin, L. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121249 · Cited by 16
“…head and source models to solve the inverse problem of determining the location and strength of neural sources within the brain based on the electrical activity recorded with scalp electrodes (Asadzadeh et al., 2020; Jatoi and Kamel, 2017; Mahjoory et al., 2017; Michel, 2019; Michel and He, 2019).”
Miraglia, F., Pappalettera, C., Ienno, S. D., Nucci, L., Cacciotti, A., Manenti, R., Judica, E., Rossini, P. M., & Vecchio, F. (2023) · Sensors · doi:10.3390/s23063143 · Cited by 11
“In fact, a series of events generate the synchronization of a large group of characteristically firing neurons, which produce post synaptic activity at different cortical sites [7,8] revealed by EEG signal in event-related potentials (ERP) components [9–11].”
BackgroundDiffuse optical tomography spatial prior for EEG source localization in human visual cortex
Cao, J., Bulger, E., Shinn‐Cunningham, B. G., Grover, P., & Kainerstorfer, J. M. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120210 · Cited by 11
Jiang, X., Ye, S., Sohrabpour, A., Bagic, A. I., & He, B. (2021) · NeuroImage Clinical · doi:10.1016/j.nicl.2021.102903 · Cited by 13
Self-citationDetecting evoked potentials with SVD- and ICA-based statistical models
Drozd, M., Husár, P., Nowakowski, A., & Henning, G. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1384101 · Cited by 11
The impact of EEG electrode density on the mapping of cortical activity networks in infants
Asayesh, A., Vanhatalo, S., & Tokariev, A. (2024) · NeuroImage · doi:10.1016/j.neuroimage.2024.120932 · Cited by 12
“…developmental disorders and conditions, highlighting its transition from a simple clinical tool to a comprehensive neuroscience platform for a better understanding of the functional dynamics of the human brain across the life span (Liu et al., 2018; Michel and Brunet, 2019; Michel and He, 2019).”
WRA-MTSI: A Robust Extended Source Imaging Algorithm Based on Multi-Trial EEG
Liu, K., Wang, Z., Yu, Z., Xiao, B., Yu, H. Z., & Wu, W. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3265376 · Cited by 10
Brinda, A. K., Doyle, A. M., Blumenfeld, M., Krieg, J. D. S., Alisch, J. S. R., Spencer, C., Lecy, E., Wilmerding, L. K., DeNicola, A. L., Johnson, L. A., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abfc1c · Cited by 10
Electromagnetic Source Imaging in Presurgical Evaluation of Children with Drug-Resistant Epilepsy
Corona, L., Rijal, S., Tanritanir, O., Shahdadian, S., Keator, C. G., Tran, L., Malik, S. I., Bosemani, M., Hansen, D. R., Shahani, D., et al. (2024) · Journal of Visualized Experiments · doi:10.3791/66494 · Cited by 11
Gordleeva, S., Grigorev, N., Николаевна, П. Е., Kurkin, S., Kazantsev, V., & Hramov, A. E. (2025) · Ageing Research Reviews · doi:10.1016/j.arr.2025.102923 · Cited by 12
Dong, K., Wei, Q., Zhang, D., Zhang, L., Wang, G., Chen, X., & Liu, J. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3221965 · Cited by 9
Neural activity during inhibitory control predicts suicidal ideation with machine learning
Nan, J., Grennan, G., Ravichandran, S., Ramanathan, D., & Mishra, J. (2024) · NPP—Digital Psychiatry and Neuroscience · doi:10.1038/s44277-024-00012-x · Cited by 9
Lee, S., Hahn, C., Seong, E., & Choi, H. S. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117181 · Cited by 11
Morik, M., Hashemi, A. B., Müller, K., Haufe, S., & Nakajima, S. (2025) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2025.3594724 · Cited by 17
Smith, E. E., Bel‐Bahar, T., & Kayser, J. (2022) · Psychophysiology · doi:10.1111/psyp.14080 · Cited by 11
Cai, Z., Pellegrino, G., Lina, J., Benali, H., & Grova, C. (2022) · Human Brain Mapping · doi:10.1002/hbm.26107 · Cited by 9
Motor networks in children with autism spectrum disorder: a systematic review on EEG studies
Bo, J., Acluche, F., Lasutschinkow, P. C., Augustiniak, A., Ditchfield, N., & Lajiness-O'Neill, R. R. (2022) · Experimental Brain Research · doi:10.1007/s00221-022-06483-8 · Cited by 8
Kaviri, S. M., & Vinjamuri, R. K. (2024) · Bioengineering · doi:10.3390/bioengineering11100967 · Cited by 12
“By contrast, source localization techniques, as evidenced in [16,23], offer greater spatial resolution, allowing for a more precise identification of neural sources related to MI tasks.”
BackgroundTakano, M., Wada, M., Nakajima, S., Taniguchi, K., Honda, S., Mimura, Y., Kitahata, R., Zomorrodi, R., Blumberger, D. M., Daskalakis, Z. J., et al. (2024) · Clinical Neurophysiology · doi:10.1016/j.clinph.2024.10.018 · Cited by 7
Frauscher, B., Bénar, C., Engel, J., Grova, C., Jacobs, J., Kahane, P., Wiebe, S., Zjilmans, M., & Dubeau, F. (2023) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2023.109221 · Cited by 7
Mentzelopoulos, G., Driscoll, N., Shankar, S., Kim, B., Rich, R., Fernandez-Nuñez, G., Stoll, H., Erickson, B. A., Medaglia, J. D., & Vitale, F. (2023) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2023.1176865 · Cited by 9
Horrillo‐Maysonnial, A., Avigdor, T., Abdallah, C., Daniel Mansilla, D., Thomas, J., von Ellenrieder, N., Royer, J., Bernhardt, B. C., Grova, C., Gotman, J., et al. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.08.009 · Cited by 11
Paramento, M., Rubega, M., Marco, R. D., Contessa, P., Agostini, M., Cantele, F., Masiero, S., & Formaggio, E. (2023) · PLoS ONE · doi:10.1371/journal.pone.0292864 · Cited by 7
Hssain‐Khalladi, S., Giron, A., Huneau, C., Gitton, C., Schwartz, D., George, N., Quyen, M. L. V., Marrelec, G., & Marchand‐Pauvert, V. (2024) · European Journal of Neuroscience · doi:10.1111/ejn.16379 · Cited by 6
Estimating neural activity from visual areas using functionally defined EEG templates
Poncet, M., & Ales, J. M. (2023) · Human Brain Mapping · doi:10.1002/hbm.26188 · Cited by 8
Leváková, M., Christensen, J. H., & Ditlevsen, S. (2022) · Royal Society Open Science · doi:10.1098/rsos.220621 · Cited by 6
EEG-connectivity: A fundamental guide and checklist for optimal study design and evaluationPreprint
Miljevic, A., Bailey, N. W., Vila‐Rodriguez, F., Herring, S. E., & Fitzgerald, P. B. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2108.13611 · Cited by 6
Encephalography cross-frequency coupling and brain alteration in amyotrophic lateral sclerosis
Benetton, C., Preuilh, A., Khamaysa, M., Chaumon, M., Lackmy‐Vallée, A., Er, A., Pélégrini‐Issac, M., Querin, G., Rouaux, C., Pradat, P., et al. (2025) · Brain Communications · doi:10.1093/braincomms/fcaf192 · Cited by 9
“Performing an accurate EEG source localization analysis 114 would be beneficial to confirm the local dysfunction at the level of the primary sensorimotor cortex.”
Briden, M., & Norouzi, N. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630605 · Cited by 5
Evaluating interhemispheric connectivity during midline object recognition using EEG
Das, A., Mandel, A., Shitara, H., Popa, T., Horovitz, S. G., Hallett, M., & Thirugnanasambandam, N. (2022) · PLoS ONE · doi:10.1371/journal.pone.0270949 · Cited by 20
EEG electrode localization with 3D iPhone scanning using point-cloud electrode selection (PC-ES)
Everitt, A. C., Richards, H., Song, Y., Smith, J., Kobylarz, E. J., Lukovits, T. G., Halter, R. J., & Murphy, E. K. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad12db · Cited by 8
Qin, Y., Wu, J., Bulger, E., Cao, J., Dehghani, H., Shinn‐Cunningham, B. G., & Kainerstorfer, J. M. (2024) · Biomedical Optics Express · doi:10.1364/boe.531576 · Cited by 6
Cortical ROI Importance Improves MI Decoding From EEG Using Fused Light Neural Network
Wang, L., Li, M., Xu, D., & Yang, Y. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3461339 · Cited by 7
Feasibility of source-level motor imagery classification for people with multiple sclerosis
Russo, J. S., Shiels, T. A., Lin, C., John, S. E., & Grayden, D. B. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adbec1 · Cited by 6
Triccas, L. T., Camilleri, K. P., Camilleri, T. A., Hnazaee, M. F., Wittevrongel, B., Muscat, F., Boccuni, L., Mantini, D., & Verheyden, G. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.881291 · Cited by 5
“EEG has a high temporal resolution and unlike fMRI, it is also a direct reflection of neural activity (Cohen, 2017; Michel and He, 2019).”
BackgroundPerceptual Awareness and Its Relationship with Consciousness: Hints from Perceptual Multistability
Saracini, C. (2022) · NeuroSci · doi:10.3390/neurosci3040039 · Cited by 7
“Nowadays, these methodologies can unveil the NCCs by overcoming the tools’ earlier limitations of poor spatial resolution thanks to novel processing methods, such as source localization [94] and spatiotemporal analyses [95] in the case of MEEG.”
BackgroundLocalization of Realistic Spatial Patches of Complex Source Activity in MEG and EEG
Giri, A., Hecker, L., Mosher, J. C., Adler, A., & Pantazis, D. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3622587 · Cited by 7
Spoa, M., Monti, S., Bjekić, J., Guerra, A., Fiorenzato, E., Cauzzo, S., Bertoldo, A., & Antonini, A. (2025) · Journal of Neural Transmission · doi:10.1007/s00702-025-03065-0 · Cited by 13
Guha, A., Popov, T. G., Bartholomew, M. E., Reed, A. C., Diehl, C., Subotnik, K. L., Ventura, J., Nuechterlein, K. H., Miller, G. A., & Yee, C. M. (2024) · Psychophysiology · doi:10.1111/psyp.14627 · Cited by 4
Continuous and discrete decoding of overt speech with scalp electroencephalography (EEG)
Craik, A., Dial, H. R., & Contreras-Vidal, J. L. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8d0a · Cited by 5
Debiased Estimation and Inference for Spatial–Temporal EEG/MEG Source Imaging
Tong, P. F., Yang, H., Ding, X., Ding, Y., Geng, X., An, S., Wang, G., & Chen, S. X. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3506596 · Cited by 5
Chen, R., Li, B.-F., Wen, J.-H., Zhong, C.-L., & Ji, M.-M. (2021) · World Journal of Clinical Cases · doi:10.12998/wjcc.v9.i33.10116 · Cited by 4
Functional connectivity of stimulus-evoked brain responses to natural speech in post-stroke aphasia
Mehraram, R., Clercq, P. D., Kries, J., Vandermosten, M., & Francart, T. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8ef9 · Cited by 6
Thurairajah, A., Freibauer, A., RamachandranNair, R., Whitney, R., Jain, P., Donner, E. J., Widjaja, E., & Jones, K. (2021) · Epilepsy Research · doi:10.1016/j.eplepsyres.2021.106810 · Cited by 5
Estimation of Granger Causality of State-Space Models using a Clustering with Gaussian Mixture Model
Plub-in, N., & Songsiri, J. (2019) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2019.8914167 · Cited by 4
“Such estimation problem is not the focus of this paper but we can refer to [11] or any source reconstruction methods [12], [13] as a solution.”
Understanding the usefulness of electroencephalography source localization
Lee, B. L. (2023) · Korean Journal of Pediatrics · doi:10.3345/cep.2022.01480 · Cited by 6
Bastola, S., Pruitt, T., Davenport, E. M., Maldjian, J. A., Liu, H., & Alexandrakis, G. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2025.1704482 · Cited by 5
A novel brain source reconstruction using a multivariate mode decomposition
Sotudeh, H., Sakhaei, S. M., & Kazemitabar, J. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acdffe · Cited by 4
Ataei, A., Amini, A., & Ghazizadeh, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-63085-w · Cited by 3
Cortex level connectivity between ACT-R modules during EEG-based n-back task
Chakladar, D. D. (2024) · Cognitive Neurodynamics · doi:10.1007/s11571-024-10177-y · Cited by 3
Ghosh, S., Cai, C., Hashemi, A. B., Gao, Y., Haufe, S., Sekihara, K., Raj, A., & Nagarajan, S. S. (2025) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2025.1386275 · Cited by 4
Riehm, C. D., Zuleger, T. M., Diekfuss, J. A., Arellano, E., & Myer, G. D. (2023) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-023-09877-5 · Cited by 4
Theta activity discriminates high-level, species-specific body processes
Chesley, J., Riecke, L., Lu, J., Vogels, R., & de Gelder, B. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00150 · Cited by 5
Ren, X., White, E. J., Kuplicki, R., Paulus, M. P., Ironside, M., Aupperle, R. L., & Stewart, J. L. (2025) · Biological Psychiatry Cognitive Neuroscience and Neuroimaging · doi:10.1016/j.bpsc.2025.02.001 · Cited by 5
Assessing Motor Cortical Activity: How Repetitions Impact Motor Execution and Imagery Analysis
Borràs, M. S., Romero, S., Serna, L. Y., Alonso, J. F., Bachiller, A., Mañanas, M. Á., & Rojas-Martínez, M. (2025) · Psychophysiology · doi:10.1111/psyp.70090 · Cited by 5
Ekstrand, C. (2022) · Oxford Research Encyclopedia of Psychology · doi:10.1093/acrefore/9780190236557.013.707 · Cited by 3
Wongtrakun, J., Zhou, S.-H., O’Connell, R. G., Chong, T. T. ‐., Bellgrove, M. A., & Coxon, J. P. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.02.05.636628 · Cited by 3
EEG electrodes and where to find them: automated localization from 3D scans
Tveter, M., Tveitstøl, T., Nygaard, T. F., T, A. S. P., Kulashekhar, S., Bruña, R., Hammer, H. L., Hatlestad‐Hall, C., & Haraldsen, I. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad7c7e · Cited by 2
Jia, Z., Xu, M., Wang, J., Jia, Z., Li, Y., Zhou, X., Liu, C., Yao, J., & Ding, Y. (2025) · ACM International Conference on Multimedia (ACM MM) · doi:10.1145/3746027.3754775 · Cited by 6
Chen, C., Xie, Y., Zhao, J., Xu, S., Cheng, L., Yi, C., Yao, D., Zhang, X., Li, F., & Xu, P. (2025) · Communications Biology · doi:10.1038/s42003-025-09029-0 · Cited by 2
A method of source localization for bioelectricity based on “Orthogonal Differential Potential”
Shang, S., Li, G., & Lin, L. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103054 · Cited by 2
Bradley, C., McCann, E., Nydam, A. S., Dux, P. E., & Mattingley, J. B. (2025) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2025.109079 · Cited by 2
Karittevlis, C., Papadopoulos, M., Lima, V., Orphanides, G. A., Tiwari, S., Antonakakis, M., Lesta, V. P., & Ioannides, A. A. (2024) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2023.1305022 · Cited by 3
“It is universally acknowledged that what distinguishes EEG and MEG from other neuroimaging techniques is their high temporal resolution which is in the order of a millisecond or less (Hämäläinen et al., 1993; He et al., 2011; Lopes da Silva, 2013; Baillet, 2017; Michel and He, 2019).”
BackgroundEEG-Based Brain Source Localization of Mental Stress
Zahour, N., Khan, M. N. A., Mir, H., & Al-Nashash, H. A. (2024) · IEEE Industrial Electronics and Applications Conference (IEACon) · doi:10.1109/ieacon61321.2024.10797447 · Cited by 1
Estimation of brain activity sources of sympathovagal dynamics
Milea, D., Catrambone, V., & Valenza, G. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121501 · Cited by 1
Cai, B., Jiang, S., Li, J., Zhong, Z., Zhang, H., Zhang, Z., Ye, X., Bao, W., Hu, J., Chen, L., et al. (2025) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2025.110648 · Cited by 1
Protocol for modulating anesthesia delta oscillations using closed loop auditory stimulation
Roca, C. P., Bazregarzadeh, H., Morisson, L., Martin, A., Verdonck, O., Gibbs, S. A., Lina, J., Carrier, J., Richebé, P., & Duclos, C. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1748528 · Cited by 1
“To extend beyond scalp measures and as an exploratory aim, source estimation will be performed using standardized head models (Michel and He, 2019).”
EEG Dipole Source Localization using Deep Neural Network
Zeng, H., Li, Y., Wang, L., Ning, Y., & Shuo, Y. (2022) · International Journal of Circuits Systems and Signal Processing · doi:10.46300/9106.2022.16.17 · Cited by 3
Time course of effective connectivity associated with perspective taking in utterance comprehension
Tokimoto, S., & Tokimoto, N. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1179230 · Cited by 2
Computational EEG Analysis of Human Epileptogenic Networks
Gnatkovsky, V., & Schindler, K. A. (2024) · Oxford University Press eBooks · doi:10.1093/med/9780197549469.003.0019 · Cited by 1
Ngoc, N. N., Nguyen, C. D., & Duc, T. V. (2025) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2949/1/012013 · Cited by 1
Role of Electrical Source Imaging in Pediatric Epilepsy and Pre-Surgical Evaluation
Thurairajah, A. (2021) · Sciential - McMaster Undergraduate Science Journal · doi:10.15173/sciential.vi6.2645
Journal, S. (2021) · Sciential - McMaster Undergraduate Science Journal · doi:10.15173/sciential.vi6.2772
EEG Connectivity During Social Engagement in Autism
Jaime, M. (2019) · Springer eBooks · doi:10.1007/978-1-4614-6435-8_102401-1
EEG Connectivity During Social Engagement in Autism
Jaime, M. (2021) · Springer eBooks · doi:10.1007/978-3-319-91280-6_102401
At Which Low Amplitude Modulated Frequency Do Infants Best Entrain? A Frequency Tagging StudyPreprint
Ives, J., Labendzki, P., Amadó, M. P., Greenwood, E., Viswanathan, N. K., Northrop, T., & Wass, S. V. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.12.08.519576
Metadata
- Authors
- Michel, C. M., & He, B.
- Affiliations
- University of Geneva (CH)
- Carnegie Mellon University (US)
- Corresponding author
- Christoph Martin Michel
- Venue
- Handbook of clinical neurology
- Publisher
- Elsevier
- Published
- 2019
- Volume
- 160
- Pages
- 85-101
- ISSN
- 0072-9752 (ISSN-L)
- OpenAlex
- W2954192080
- Semantic Scholar
- 19b0c85dc05913992833265cf619f79e7a51cc84
- Cited by
- 134
- References
- 152
- Citations by year
- 2026: 14 · 2025: 38 · 2024: 29 · 2023: 19 · 2022: 18 · 2021: 12 · 2020: 1 · 2019: 2
- FWCI
- 21.51
- Type
- book chapter
- Language
- en
- Open access
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Handbook of clinical neurology (publishedVersion)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- Funders
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (320030_159705)
- National Center of Competence in Research Quantum Science and Technology (51AU40_125759)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEG source localization, dipole fitting, epilepsy, presurgical planning, magnetoencephalography, brain networks, temporal resolution
- MeSH terms
- Brain, Brain Mapping, Electroencephalography, Humans, Magnetoencephalography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.