Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,673

The DOI matches its Crossref record.

Current source-density method and application in cat cerebral cortex: investigation of evoked potentials and EEG phenomena

Mitzdorf, U.·1985·Physiological Reviews

Abstract

II. Current Source-Density (CSD) Method................................. 39 A. Physical and physiological basis.................................... 39 B. Experimental CSD studies......................................... 4.2 C. Interpretation of CSDs............................................ 44

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/physrev.1985.65.1.37

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,673

Metadata

Authors
Mitzdorf, U.
Venue
Physiological Reviews
Published
1985-01-01
Volume
65
Issue
1
Pages
37-100
ISSN
  • 0031-9333 (ISSN-L)
  • 1522-1210
OpenAlex
W2111736228
Cited by
1,673
References
0
FWCI
9.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current source-density method and application in cat cerebral cortex: investigation of evoked potentials and EEG phenomena. https://app.cochat.ai/papers/10.1152/physrev.1985.65.1.37
The paper
Mitzdorf, U. (1985). Current source-density method and application in cat cerebral cortex: investigation of evoked potentials and EEG phenomena. Physiological Reviews. https://doi.org/10.1152/physrev.1985.65.1.37

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.