Comparison of biosensor platforms in the evaluation of high affinity antibody-antigen binding kinetics

Open access
Yang, Danlin, Singh, Ajit, Wu, Helen, Kroe-Barrett, Rachel·2016·Analytical Biochemistry

Abstract

The acquisition of reliable kinetic parameters for the characterization of biomolecular interactions is an important component of the drug discovery and development process. While several benchmark studies have explored the variability of kinetic rate constants obtained from multiple laboratories and biosensors, a direct comparison of these instruments' performance has not been undertaken, and systematic factors contributing to data variability from these systems have not been discussed. To address these questions, a panel of ten high-affinity monoclonal antibodies was simultaneously evaluated for their binding kinetics against the same antigen on four biosensor platforms: GE Healthcare's Biacore T100, Bio-Rad's ProteOn XPR36, ForteBio's Octet RED384, and Wasatch Microfluidics's IBIS MX96. We compared the strengths and weaknesses of these systems and found that despite certain inherent systematic limitations in instrumentation, the rank orders of both the association and dissociation rate constants were highly correlated between these instruments. Our results also revealed a trade-off between data reliability and sample throughput. Biacore T100, followed by ProteOn XPR36, exhibited excellent data quality and consistency, whereas Octet RED384 and IBIS MX96 demonstrated high flexibility and throughput with compromises in data accuracy and reproducibility. Our results support the need for a "fit-for-purpose" approach in instrument selection for biosensor studies.

Integrity signals

Registry

Crossref · 10.1016/j.ab.2016.06.024

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Surface plasmon resonance quantifies adenoviruses in downstream samples, with low throughput being its main drawback compared to BLI.

    “First, surface plasmon resonance, like BLI, quantifies the concentration of an analyte by measuring changes to the optical properties of a sensor chip, in this case, a shift in the resonance angle of free electrons exited by polarized light, caused by analyte binding to immobilized antibodies on its surface. It successfully quantifies adenoviruses in downstream samples,120 with low throughput”

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Sikkema, 1989, An Fc-binding protein, Am. Biotechnol. Lab., 7, 42

Cited by

Sorted by citations

Authors
Yang, D., Singh, A., Wu, H., & Kroe-Barrett, R.
Affiliations
Boehringer Ingelheim (United States) (US)
Venue
Analytical Biochemistry
Publisher
Elsevier BV
Published
2016-09
Volume
508
Pages
78-96
ISSN
0003-2697 (ISSN-L)
OpenAlex
W2470598491
Cited by
120
References
24
Citations by year
2026: 4 · 2025: 9 · 2024: 14 · 2023: 15 · 2022: 11 · 2021: 17 · 2020: 9 · 2019: 16 · 2018: 11 · 2017: 13 · 2016: 1
FWCI
7.10
Type
journal article
Language
en
Open access
Locations
  • Analytical Biochemistry (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Monoclonal and Polyclonal Antibodies Research
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
Keywords
antibody-antigen binding kinetics, association rate constant, dissociation rate constant, data reproducibility, sample throughput, instrument selection, biomolecular interactions
MeSH terms
Antibodies, Monoclonal, Antibody Affinity, Kinetics, Ligands, Protein Binding, Reproducibility of Results, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review