Coacervative extraction of Ochratoxin A in wines prior to liquid chromatography/fluorescence determination
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Coacervates made up of reverse micelles of decanoic acid were assessed as a new strategy for the simplification of wine sample treatment in the determination of Ochratoxin A (OTA). Simultaneous extraction/concentration of this contaminant was based on both hydrophobic and hydrogen bond OTA:coacervate interactions. Parameters affecting extraction efficiency and concentration factors were studied. Concentrations of decanoic acid and tetrahydrofuran (THF) were the most influential parameters, being 0.5% of acid and 5% of THF the selected ones. The procedure was very robust, so that the extractions were not influenced by the pH and the nature or concentration of matrix components. OTA recoveries from different types of wines (white, rosé and red) ranged between 85 and 100% and the actual concentration factors varied from 105 to 125 for sample volumes of 15 mL. The detection limits for OTA, after liquid chromatography/fluorimetry (LC/FL) analysis of the coacervate (20 microL), were 4.5 ng L(-1) in white and rosé wines and 15 ng L(-1) in red wines, values which were far below the threshold limit established for OTA by EU directives (2.0 microg L(-1)). No clean-up of the extracts was required for any of the samples analysed. The overall sample treatment took about 15-20 min and several samples could be simultaneously treated using conventional lab equipment. The precision of the method, expressed as relative standard deviation, was about 5%. The approach developed was successfully applied to the determination of OTA in different wine samples from the South of Spain. The concentrations found ranged between 0.015 and 0.091 microg L(-1).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carabias-Martı́nez, R., Rodrı́guez-Gonzalo, E., Moreno-Cordero, B., Pérez-Pavón, J. L., Garcı́a-Pinto, C., & Fernández Laespada, E. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00837-2 · Cited by 392
Casero, I., Sicilia, D., Rubio, S., & Pérez-Bendito, D. (1999) · Analytical Chemistry · doi:10.1021/ac990106g · Cited by 196
Self-citation
Cited by
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Supramolecular solvents in the extraction of organic compounds. A review
Ballesteros-Gómez, A., Sicilia, M. D., & Rubio, S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.07.027 · Cited by 320
Self-citationSustainable green solvents for microextraction techniques: Recent developments and applications
Carasek, E., Bernardi, G., Morelli, D., & Merib, J. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461944 · Cited by 99
Supramolecular Solvents for Green Chemistry
Caballo, C., Sicilia, M. D., & Rubio, S. (2017) · The Application of Green Solvents in Separation Processes · doi:10.1016/b978-0-12-805297-6.00005-x · Cited by 54
Self-citation
Metadata
- Authors
- García-Fonseca, S., Ballesteros-Gómez, A., Rubio, S., & Pérez-Bendito, D.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2008-06
- Volume
- 617
- Issue
- 1-2
- Pages
- 3-10
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2025034679
- Cited by
- 45
- References
- 2
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.