Fast and simultaneous determination of phenolic compounds and caffeine in teas, mate, instant coffee, soft drink and energetic drink by high-performance liquid chromatography using a fused-core column
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A fast HPLC method with diode-array absorbance detector and fluorescence detector for the analysis of 19 phenolic acids, flavan-3-ols, flavones, flavonols and caffeine in different types of samples was developed. Using a C(18) reverse-phase fused-core column separation of all compounds was achieved in less than 5 min with an overall sample-to-sample time of 10 min. Evaluation of chromatographic performance revealed excellent reproducibility, resolution, selectivity and peak symmetry. Limits of detection for all analyzed compounds ranged from 0.5 to 211 μg L(-1), while limits of quantitation ranged between 1.5 and 704 μg L(-1). The developed method was used for the determination of analytes present in different samples, including teas (black, white, green), mate, coffee, cola soft drink and an energetic drink. Concentration of the analyzed compounds occurring in the samples ranged from 0.4 to 314 mg L(-1). Caffeine was the analyte found in higher concentrations in all samples. Phytochemical profiles of the samples were consistent with those reported in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polyphenols: Food sources and bioavailability
Manach, C., Scalbert, A., Morand, C., Rémésy, C., & Jiménez, L. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.5.727 · Cited by 8,175
Ultrasound-assisted extraction of soy isoflavones
Rostagno, M. A., Palma, M., & Barroso, C. G. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01184-1 · Cited by 563
Self-citationMoon, J.-K., Yoo, H. S., & Shibamoto, T. (2009) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf900012b · Cited by 254
Cited by
da Silva, L. C., Souza, M. C., Sumere, B. R., Silva, L. G. S., da Cunha, D. T., Barbero, G. F., Bezerra, R. M. N., & Rostagno, M. A. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2020.126450 · Cited by 82
Self-citationContieri, L. S., de Souza Mesquita, L. M., Sanches, V. L., Chaves, J., Pizani, R. S., da Silva, L. C., Viganó, J., Ventura, S. P. M., & Rostagno, M. A. (2022) · Separation and Purification Technology · doi:10.1016/j.seppur.2022.121640 · Cited by 50
“Thus, the recovery of target compounds must be carried out using the most appropriate extraction process and the optimized conditions, guaranteeing a better use of the raw material, lower process costs, and good extraction selectivity (in this case, by removing waxes) [10].”
MethodSelf-citation
Metadata
- Authors
- Rostagno, M. A., Manchón, N., D’Arrigo, M., Guillamón, E., Villares, A., García-Lafuente, A., Ramos, A., & Martínez, J. A.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 685
- Issue
- 2
- Pages
- 204-211
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2088607907
- Cited by
- 162
- References
- 3
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.