The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Determination of nitrite in saliva using microfluidic paper-based analytical devices
Open accessAbstract
Point-of-care platforms can provide fast responses, decrease the overall cost of the treatment, allow for in-home determinations with or without a trained specialist, and improve the success of the treatment. This is especially true for microfluidic paper-based analytical devices (μPAD), which can enable the development of highly efficient and versatile analytical tools with applications in a variety of biomedical fields. The objective of this work was the development of μPADs to identify and quantify levels of nitrite in saliva, which has been proposed as a potential marker of periodontitis. The devices were fabricated by wax printing and allowed the detection of nitrite by a colorimetric reaction based on a modified version of the Griess reaction. The presented modifications, along with the implementation of a paper-based platform, address many of the common drawbacks (color development, stability, etc.) associated with the Griess reaction and are supported by results related to the design, characterization, and application of the proposed devices. Under the optimized conditions, the proposed devices enable the determination of nitrite in the 10 to 1000 μmol L−1 range with a limit of detection of 10 μmol L−1 and a sensitivity of 47.5 AU [log (μmol L−1)]−1. In order to demonstrate the potential impact of this technology in the healthcare industry, the devices were applied to the analysis of a series of real samples, covering the relevant clinical range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Walker, R. (1990) · Food Additives and Contaminants · doi:10.1080/02652039009373938 · Cited by 391
Nitric oxide synthesis and severity of human periodontal disease
Batista, A., Silva, T., Chun, J., & Lara, V. (2002) · Oral Diseases · doi:10.1034/j.1601-0825.2002.02852.x · Cited by 158
Urinary nitrite: more than a marker of infection
Lundberg, J. O. N., Carlsson, S., Engstrand, L., Morcos, E., Wiklund, N. P., & Weitzberg, E. (1997) · Urology · doi:10.1016/s0090-4295(97)00257-4 · Cited by 108
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M., & Carrilho, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.037 · Cited by 434
Self-citationBeyond the lateral flow assay: A review of paper-based microfluidics
Carrell, C., Kava, A., Nguyen, M., Menger, R., Munshi, Z., Call, Z., Nussbaum, M., & Henry, C. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2018.12.002 · Cited by 336
Metadata
- Authors
- Bhakta, S. A., Borba, R., Taba, M., Garcia, C. D., & Carrilho, E.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 809
- Pages
- 117-122
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W1966763105
- Cited by
- 173
- References
- 3
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.