Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 165

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reduced graphene oxide/nile blue/gold nanoparticles complex-modified glassy carbon electrode used as a sensitive and label-free aptasensor for ratiometric electrochemical sensing of dopamine

Jin, Hui, Zhao, Chunqin, Gui, Rijun, Gao, Xiaohui, Wang, Zonghua · 2018 · Analytica Chimica Acta

Abstract

In this work, glassy carbon electrode (GCE) surface was modified by drop-coating graphene oxide (GO) and nile blue (NB) to form GO/NB/GCE. By using a one-step coreduction treatment under cyclic voltammetry (CV) scanning, gold nanoparticles (AuNPs) were electrodeposited onto GO/NB/GCE surface, simultaneously generating reduced GO (rGO). AuNPs from the prepared rGO/NB/AuNPs/GCE was combined with 5'-SH-terminated aptamer of dopamine (DA) via Au-S coupling to fabricate aptamer-rGO/NB/AuNPs/GCE system. DA specifically combined with its aptamer modified on rGO/NB/AuNPs/GCE surface. CV, electrochemical impedance spectroscopy, square wave voltammetry responses of this system as the working electrode were measured. With the addition of DA, the peak current intensities located at -0.45 V (INB) and 0.15 V (IDA) showed gradually decreased and increased changes, respectively. There was a good linear (R2 = 0.9922) relationship between lg(IDA/INB) and the logarithm of DA concentration (lgCDA) in the CDA range from 10 nM to 0.2 mM, showing a low detection limit of 1 nM. This system as a novel, sensitive and label-free aptasensor was used for ratiometric electrochemical sensing of DA. Experimental results verified that this aptasensor possessed high stability, selectivity and sensitivity towards DA detection, over potential interferents. This aptasensor efficiently determined DA in real biological samples, together with high detection recoveries of 97.0-104.0%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.aca.2018.03.036

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 165

Metadata

Authors
Jin, H., Zhao, C., Gui, R., Gao, X., & Wang, Z.
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2018-09
Volume
1025
Pages
154-162
ISSN
0003-2670 (ISSN-L)
OpenAlex
W2795122808
Cited by
165
References
1
FWCI
8.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduced graphene oxide/nile blue/gold nanoparticles complex-modified glassy carbon electrode used as a sensitive and label-free aptasensor for ratiometric electrochemical sensing of dopamine. https://app.cochat.ai/papers/10.1016/j.aca.2018.03.036
The paper
Jin, H., Zhao, C., Gui, R., Gao, X., & Wang, Z. (2018). Reduced graphene oxide/nile blue/gold nanoparticles complex-modified glassy carbon electrode used as a sensitive and label-free aptasensor for ratiometric electrochemical sensing of dopamine. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2018.03.036

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.