Polymeric ionic liquid open tubular capillary column for on-line in-tube SPME coupled with UHPLC-MS/MS to determine endocannabinoids in plasma samples
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This manuscript describes the development of wall-coated open tubular capillary column with polymeric ionic liquids (PILs) for on-line in-tube solid phase microextraction coupled with ultra high-performance liquid chromatography tandem mass spectrometry (in-tube SPME/UHPLC-MS/MS) to determine anandamide (AEA) and 2-arachidonoyl glycerol (2 A G) in plasma samples. Selective PILs were synthetized from the [VC6IM][Cl], [VC16IM][Br], and [(VIM)2C10]2 [Br] - ionic liquids - by in-situ thermal-initiated polymerization in a fused silica capillary column for in-tube SPME. The synthesis procedure was optimized, and the capillary columns were characterized using spectroscopic and chromatography techniques. The chemically bonded and cross-linked PIL-based sorbent phase (thickness coating: 1.7 μm) presented high chemical and mechanical stability. Among the sorbents evaluated, the PIL-based capillary, [VC16IM][Br]/[(VIM)2C10]2 [Br] presented the best performance with a sorption capacity of 37,311 ng cm-3 and 48,307 ng cm-3 for AEA and 2 A G, respectively. This capillary was reused more than ninety times without significant changes in extraction efficiency. The in-tube SPME-UHPLC-MS/MS method presented a linear range from 0.1 ng mL-1 to 100 ng mL-1 for AEA, and from 0.05 ng mL-1 to 100 ng mL-1 for 2 A G, with coefficients of determination higher than 0.99, p-value for Lack-of-fit test higher than 0.05 (α of 0.05), precision with coefficient of variation (CV) values ranging from 1.6 to 14.0% and accuracy with relative standard deviation (RSD) values from -19.6% to 13.2%. This method was successfully applied to determine AEA and 2 A G in plasma patients with Parkinson's disease. The concentrations in these plasma samples ranged from 0.14 to 0.46 ng mL-1 for AEA and from <0.05 ng mL-1 to 0.51 ng mL-1 for 2-AG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characteristics and adsorption capacities of low-cost sorbents for wastewater treatment: A review
De Gisi, S., Lofrano, G., Grassi, M., & Notarnicola, M. (2016) · Sustainable Materials and Technologies · doi:10.1016/j.susmat.2016.06.002 · Cited by 1,676
Enzymatic pathways that regulate endocannabinoid signaling in the nervous system
Ahn, K., McKinney, M. K., & Cravatt, B. F. (2008) · Chemical Reviews · doi:10.1021/cr0782067 · Cited by 529
Cited by
Advances of ionic liquids in analytical Chemistry
Trujillo-Rodríguez, M. J., Nan, H., Varona, M., Emaus, M. N., Souza, I. D., & Anderson, J. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04710 · Cited by 248
Self-citationIonic liquids in the microextraction techniques: The influence of ILs structure and properties
Yavir, K., Konieczna, K., Marcinkowski, Ł., & Kloskowski, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115994 · Cited by 134
Application of ionic liquids in microextraction techniques: Current trends and future perspectives
Marcinkowska, R., Konieczna, K., Marcinkowski, Ł., Namieśnik, J., & Kloskowski, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.025 · Cited by 119
Metadata
- Authors
- Souza, I. D., Hantao, L. W., & Queiroz, M. E. C.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 1045
- Pages
- 108-116
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2892297919
- Cited by
- 60
- References
- 2
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polymeric ionic liquid open tubular capillary column for on-line in-tube SPME coupled with UHPLC-MS/MS to determine endocannabinoids in plasma samples. https://app.cochat.ai/papers/10.1016/j.aca.2018.08.062
- The paper
- Souza, I. D., Hantao, L. W., & Queiroz, M. E. C. (2019). Polymeric ionic liquid open tubular capillary column for on-line in-tube SPME coupled with UHPLC-MS/MS to determine endocannabinoids in plasma samples. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2018.08.062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.