Quartz-enhanced photoacoustic spectroscopy for multi-gas detection: A review
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Multi-gas detection represents a suitable solution in many applications, such as environmental and atmospheric monitoring, chemical reaction and industrial process control, safety and security, oil&gas and biomedicine. Among optical techniques, Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) has been demonstrated to be a leading-edge technology for addressing multi-gas detection, thanks to the modularity, ruggedness, portability and real time operation of the QEPAS sensors. The detection module consists in a spectrophone, mounted in a vacuum-tight cell and detecting sound waves generated via photoacoustic excitation within the gas sample. As a result, the sound detection is wavelength-independent and the volume of the absorption cell is basically determined by the spectrophone dimensions, typically in the order of few cubic centimeters. In this review paper, the implementation of the QEPAS technique for multi-gas detection will be discussed for three main areas of applications: i) multi-gas trace sensing by exploiting non-interfering absorption features; ii) multi-gas detection dealing with overlapping absorption bands; iii) multi-gas detection in fluctuating backgrounds. The fundamental role of the analysis and statistical tools will be also discussed in detail in relation with the specific applications. This overview on QEPAS technique, highlighting merits and drawbacks, aims at providing ready-to-use guidelines for multi-gas detection in a wide range of applications and operating conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Wold, S., Ruhe, A., Wold, H., & Dunn, III (1984) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0905052 · Cited by 2,529
Hawkins, D. M. (2004) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci0342472 · Cited by 2,522
Metadata
- Authors
- Sampaolo, A., Patimisco, P., Giglio, M., Zifarelli, A., Wu, H., Dong, L., & Spagnolo, V.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2022-04
- Volume
- 1202
- Pages
- 338894
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W3194682408
- Cited by
- 229
- References
- 4
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quartz-enhanced photoacoustic spectroscopy for multi-gas detection: A review. https://app.cochat.ai/papers/10.1016/j.aca.2021.338894
- The paper
- Sampaolo, A., Patimisco, P., Giglio, M., Zifarelli, A., Wu, H., Dong, L., & Spagnolo, V. (2022). Quartz-enhanced photoacoustic spectroscopy for multi-gas detection: A review. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2021.338894
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.