Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 222

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Computed Tomography Scans in the Evaluation of Fatty Liver Disease in a Population Based Study

Open access
Zeb, Irfan, Li, Dong, Nasir, Khurram, Katz, Ronit, Larijani, Vahid N., Budoff, Matthew J. · 2012 · Academic Radiology

Abstract

Rationale and Objectives Fatty liver disease is a common clinical entity in hepatology practice. This study evaluates the prevalence and reproducibility of computed tomography (CT) measures for diagnosis of fatty liver and compares commonly used CT criteria for the diagnosis of liver fat. Materials and Methods The study includes 6,814 asymptomatic participants from a population based sample. The ratio of liver-to-spleen (L/S) Hounsfield units (HU) <1.0 and liver attenuation <40HU were utilized for diagnosing and assessing the severity of liver fat content. Participants with heavy alcohol intake (>7 drinks/week for women and >14 drinks/week for men) were excluded. Final analysis was performed on participants where images of both liver and spleen were available on the scans. Results The overall prevalence of fatty liver (4,175 patients) was 17.2% (using L/S ratio <1.0), with 6.3% (with <40HU cutoff) of the population having moderate to severe steatosis (>30% liver fat content). The prevalence was high in participants with dyslipidemia (70.4%), hypertension (56.8%) and obesity (53%). Diabetic patients had 24.1% prevalence of fatty liver. The prevalence provided by L/S ratio <1.0 (17.2%) was comparable to prevalence provided by <51 HU (17.3%), whereas prevalence obtained by <40HU (6.3%) cutoff corresponded to L/S ratio of <0.8 (6.5%). The measurements of liver and spleen HU attenuations were highly reproducible (0.96, 0.99 and 0.99, 0.99 for intra- and inter-reader variability, respectively) in a sample of 100 scans. Conclusion Fatty liver can be reliably diagnosed using non-enhanced CT scans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.acra.2012.02.022

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Zeb, I., Li, D., Nasir, K., Katz, R., Larijani, V. N., & Budoff, M. J.
Venue
Academic Radiology
Publisher
Elsevier BV
Published
2012-07
Volume
19
Issue
7
Pages
811-818
ISSN
1076-6332 (ISSN-L)
OpenAlex
W159814998
Cited by
222
References
8
FWCI
4.09
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.