Automated Tumor Volumetry Using Computer-Aided Image Segmentation
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Rationale and Objectives Accurate segmentation of brain tumors, and quantification of tumor volume, is important for diagnosis, monitoring, and planning therapeutic intervention. Manual segmentation is not widely used because of time constraints. Previous efforts have mainly produced methods that are tailored to a particular type of tumor or acquisition protocol and have mostly failed to produce a method that functions on different tumor types and is robust to changes in scanning parameters, resolution, and image quality, thereby limiting their clinical value. Herein, we present a semiautomatic method for tumor segmentation that is fast, accurate, and robust to a wide variation in image quality and resolution. Materials and Methods A semiautomatic segmentation method based on the geodesic distance transform was developed and validated by using it to segment 54 brain tumors. Glioblastomas, meningiomas, and brain metastases were segmented. Qualitative validation was based on physician ratings provided by three clinical experts. Quantitative validation was based on comparing semiautomatic and manual segmentations. Results Tumor segmentations obtained using manual and automatic methods were compared quantitatively using the Dice measure of overlap. Subjective evaluation was performed by having human experts rate the computerized segmentations on a 0–5 rating scale where 5 indicated perfect segmentation. Conclusions The proposed method addresses a significant, unmet need in the field of neuro-oncology. Specifically, this method enables clinicians to obtain accurate and reproducible tumor volumes without the need for manual segmentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multicenter phase II trial of temozolomide in patients with glioblastoma multiforme at first relapse
Brada, M., Hoang-Xuan, K., Rampling, R., Dietrich, P.-Y., Dirix, L. Y., Macdonald, D., Heimans, J. J., Zonnenberg, B. A., Bravo-Marques, J. M., Henriksson, R., et al. (2001) · Annals of Oncology · doi:10.1023/a:1008382516636 · Cited by 372
GeoS: Geodesic Image Segmentation
Criminisi, A., Sharp, T., & Blake, A. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-88682-2_9 · Cited by 277
Cited by
Bakas, S., Akbari, H., Sotiras, A., Bilello, M., Rozycki, M., Kirby, J. S., Freymann, J. B., Farahani, K., & Davatzikos, C. (2017) · Scientific Data · doi:10.1038/sdata.2017.117 · Cited by 3,049
“The geodesic distance between v i and v s was estimated using the fast marching method 84,85 and by taking into account local image gradient magnitude 86 .”
Self-citationMcBee, M. P., Awan, O. A., Colucci, A. T., Ghobadi, C. W., Kadom, N., Kansagra, A. P., Tridandapani, S., & Auffermann, W. F. (2018) · Academic Radiology · doi:10.1016/j.acra.2018.02.018 · Cited by 496
Binder, Z. A., Thorne, A. H., Bakas, S., Wileyto, E. P., Bilello, M., Akbari, H., Rathore, S., Ha, S. M., Zhang, L., Ferguson, C. J., et al. (2018) · Cancer Cell · doi:10.1016/j.ccell.2018.06.006 · Cited by 169
Self-citationBakas, S., Zeng, K., Sotiras, A., Rathore, S., Akbari, H., Gaonkar, B., Rozycki, M., Pati, S., & Davatzikos, C. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-30858-6_13 · Cited by 101
“Similar to the approach taken in [7], we set the weight P at each voxel to be proportional to its gradient magnitude, and the optimization was solved using the fast marching method [4,19].”
MethodSelf-citationRathore, S., Bakas, S., Pati, S., Akbari, H., Kalarot, R., Sridharan, P., Rozycki, M., Bergman, M., Tunc, B., Verma, R., et al. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-75238-9_12 · Cited by 57
“The segmentation of brain structures based on the GDT [20], is a patient-based method fully incorporated in brain-CaPTk.”
MethodInfluentialSelf-citation
Metadata
- Authors
- Gaonkar, B., Macyszyn, L., Bilello, M., Sadaghiani, M. S., Akbari, H., Attiah, M. A., Ali, Z. S., Da, X., Zhan, Y., Rourke, D. O., Grady, S. M., & Davatzikos, C.
- Venue
- Academic Radiology
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 22
- Issue
- 5
- Pages
- 653-661
- ISSN
- 1076-6332 (ISSN-L)
- OpenAlex
- W1977232575
- Cited by
- 39
- References
- 2
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Tumor Volumetry Using Computer-Aided Image Segmentation. https://app.cochat.ai/papers/10.1016/j.acra.2015.01.005
- The paper
- Gaonkar, B., Macyszyn, L., Bilello, M., Sadaghiani, M. S., Akbari, H., Attiah, M. A., Ali, Z. S., Da, X., Zhan, Y., Rourke, D. O., Grady, S. M., & Davatzikos, C. (2015). Automated Tumor Volumetry Using Computer-Aided Image Segmentation. Academic Radiology. https://doi.org/10.1016/j.acra.2015.01.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.