MR Angiography of Renal Transplant Vasculature with Ferumoxytol:
Open accessAbstract
Rationale and objectives This work aimed to quantify the differences in signal-to-noise ratio (SNR) and vessel sharpness between steady-state and first-pass magnetic resonance angiography (MRA) with ferumoxytol in renal transplant recipients.Materials and methods We performed a retrospective study of adult patients who underwent steady-state and first-pass MRA with ferumoxytol to evaluate renal transplant vasculature. SNR was calculated in the external iliac artery, and vessel sharpness was calculated in the external iliac and renal transplant arteries for both acquisitions. Data were compared using Student's t test.Results Fifteen patients were included (mean age 56.9 years, 10 males). The mean SNR of the external iliac artery was 42.2 (SD, 11.9) for the first-pass MRA and 41.8 (SD, 9.7) for the steady-state MRA (p = 0.92). The mean vessel sharpness was significantly higher for the steady-state MRA compared to first-pass MRA for both external iliac (1.24 vs. 0.80 mm(-1), p < 0.01) and renal transplant arteries (1.26 vs. 0.79 mm(-1), p < 0.01).Conclusion Steady-state MRA using ferumoxytol improves vessel sharpness while maintaining equivalent SNR compared to conventional first-pass MRA in renal transplant patients.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Steady-state ferumoxytol-enhanced MRA shows clear improvement in vessel delineation compared to first-pass MRA in patients with kidney transplants.
“a study conducted by Corwin et al. investigated two different modes of ferumoxytol-enhanced MRA, and showed a clear improvement in vessel delineation for steady-state MRA compared to first-pass MRA in patients with kidney transplants [189].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [189]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
FDA report: Ferumoxytol for intravenous iron therapy in adult patients with chronic kidney disease
Lu, M., Cohen, M. H., Rieves, D., & Pazdur, R. (2010) · American Journal of Hematology · doi:10.1002/ajh.21656 · Cited by 443 · see citing works
Emerging applications for ferumoxytol as a contrast agent in MRI
Bashir, M. R., Bhatti, L., Marin, D., & Nelson, R. C. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24691 · Cited by 373 · see citing works
Vascular Imaging With Ferumoxytol as a Contrast Agent
Hope, M. D., Hope, T. A., Zhu, C., Faraji, F., Haraldsson, H., Ordovas, K. G., & Saloner, D. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14534 · Cited by 137 · see citing works
Ferumoxytol as an off-label contrast agent in body 3T MR angiography: a pilot study in children
Ruangwattanapaisarn, N., Hsiao, A., & Vasanawala, S. S. (2014) · Pediatric Radiology · doi:10.1007/s00247-014-3226-3 · Cited by 61 · see citing works
Liu, X., Berg, N., Sheehan, J., et al. (2009) · Radiology · doi:10.1148/radiol.2512081094 · Cited by 61 · see citing works
USPIO-enhanced MR angiography of arteriovenous fistulas in patients with renal failure
Sigovan, M., Gasper, W., Alley, H. F., Owens, C. D., & Saloner, D. (2012) · Radiology · doi:10.1148/radiol.12112694 · Cited by 55 · see citing works
Renal Transplant Imaging Using Magnetic Resonance Angiography With a Nonnephrotoxic Contrast Agent
Bashir, M. R., Jaffe, T. A., Brennan, T. V., Patel, U. D., & Ellis, M. J. (2013) · Transplantation · doi:10.1097/tp.0b013e318295464c · Cited by 54 · see citing works
Imaging of the renal transplant: comparison of MRI with duplex sonography
Browne, R. F. J., & Tuite, D. J. (2006) · Abdominal Imaging · doi:10.1007/s00261-005-0394-5 · Cited by 53 · see citing works
First-Pass and Steady-State MR Angiography of Thoracic Vasculature in Children and Adolescents
Naehle, C. P., Kaestner, M., Müller, A., et al. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2009.12.015 · Cited by 41 · see citing works
Anzidei, M., Napoli, A., Marincola, B. C., et al. (2009) · Radiology · doi:10.1148/radiol.2512081197 · Cited by 37 · see citing works
Tang, H., Wang, Z., Wang, L., et al. (2014) · Radiology · doi:10.1148/radiol.14131800 · Cited by 29 · see citing works
Anaphylaxis with elevated serum tryptase after administration of intravenous ferumoxytol
Santosh, S., Podaralla, P., & Miller, B. W. (2010) · Clinical Kidney Journal · doi:10.1093/ndtplus/sfq084 · Cited by 29 · see citing works
Management of Transplant Renal Artery Stenosis
Rajan, D. K., Stavropoulos, S. W., & Shlansky-Goldberg, R. D. (2005) · Seminars in Interventional Radiology · doi:10.1055/s-2004-861560 · Cited by 26 · see citing works
Fananapazir, G., Marin, D., Suhocki, P. V., Kim, C., & Bashir, M. R. (2014) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2013.12.019 · Cited by 25 · see citing works
Self-citationBultman, E. M., Klaers, J. L., Johnson, K. M., et al. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.10.004 · Cited by 13 · see citing works
Doppler-Ultrasound measurements in renal allografts depend on the patients body position
Steubl, Papachristou, Wolf, et al. (2012) · VASA · doi:10.1024/0301-1526/a000173 · Cited by 7 · see citing works
Anastomosis of Accessory Arteries Via Microsurgical Technique in Renal Transplantation
Mersa, B., Gürkan, A., Özçelik, B., et al. (2011) · Transplantation Proceedings · doi:10.1016/j.transproceed.2011.01.114 · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181 · see citing works
- Authors
- Corwin, M. T., Fananapazir, G., & Chaudhari, A. J.
- Affiliations
- University of California Davis Medical Center (US)
- Corresponding author
- Corwin, Michael T.
- Venue
- Academic Radiology
- Publisher
- Elsevier BV
- Published
- 2016-03
- Volume
- 23
- Issue
- 3
- Pages
- 368-373
- ISSN
- 1076-6332 (ISSN-L)
- PMC
- PMC4855839
- OpenAlex
- W2203570087
- Cited by
- 35
- References
- 17
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 2 · 2022: 4 · 2021: 2 · 2020: 2 · 2019: 5 · 2018: 7 · 2017: 3 · 2016: 5 · 2015: 1
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Academic Radiology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (R03EB015099)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (K12HD051958)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Renal and Vascular Pathologies
- Physical Sciences › Materials Science › Materials Chemistry › Lanthanide and Transition Metal Complexes
- Keywords
- ferumoxytol, magnetic resonance angiography, signal-to-noise ratio, vessel sharpness, kidney transplant recipients, external iliac artery
- MeSH terms
- Adult, Algorithms, Contrast Media, Female, Humans, Iliac Artery, Image Enhancement, Image Processing, Computer-Assisted, Kidney, Male, Middle Aged, Radiography, Retrospective Studies, Kidney Transplantation, Magnetic Resonance Angiography, Imaging, Three-Dimensional, Ferrosoferric Oxide, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review