The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Deep Learning Reconstruction at CT: Phantom Study of the Image Characteristics
Abstract
OBJECTIVES Noise, commonly encountered on computed tomography (CT) images, can impact diagnostic accuracy. To reduce the image noise, we developed a deep-learning reconstruction (DLR) method that integrates deep convolutional neural networks into image reconstruction. In this phantom study, we compared the image noise characteristics, spatial resolution, and task-based detectability on DLR images and images reconstructed with other state-of-the art techniques. METHODS We scanned a phantom harboring cylindrical modules with different contrast on a 320-row detector CT scanner. Phantom images were reconstructed with filtered back projection, hybrid iterative reconstruction, model-based iterative reconstruction, and DLR. The standard deviation of the CT number and the noise power spectrum were calculated for noise characterization. The 10% modulation-transfer function (MTF) level was used to evaluate spatial resolution; task-based detectability was assessed using the model observer method. RESULTS On images reconstructed with DLR, the noise was lower than on images subjected to other reconstructions, especially at low radiation dose settings. Noise power spectrum measurements also showed that the noise amplitude was lower, especially for low-frequency components, on DLR images. Based on the MTF, spatial resolution was higher on model-based iterative reconstruction image than DLR image, however, for lower-contrast objects, the MTF on DLR images was comparable to images reconstructed with other methods. The machine observer study showed that at reduced radiation-dose settings, DLR yielded the best detectability. CONCLUSION On DLR images, the image noise was lower, and high-contrast spatial resolution and task-based detectability were better than on images reconstructed with other state-of-the art techniques. DLR also outperformed other methods with respect to task-based detectability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Learning: A Primer for Radiologists
Chartrand, G., Cheng, P. M., Vorontsov, E., Drozdzal, M., Turcotte, S., Pal, C. J., Kadoury, S., & Tang, A. (2017) · RadioGraphics · doi:10.1148/rg.2017170077 · Cited by 1,115
Cited by
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
Koetzier, L. R., Mastrodicasa, D., Szczykutowicz, T. P., van der Werf, N. R., Wang, A. S., Sandfort, V., van der Molen, A. J., Fleischmann, D., & Willemink, M. J. (2023) · Radiology · doi:10.1148/radiol.221257 · Cited by 427
Data drift in medical machine learning: implications and potential remedies
Sahiner, B., Chen, W., Samala, R. K., & Petrick, N. (2023) · The British Journal of Radiology · doi:10.1259/bjr.20220878 · Cited by 279
Metadata
- Authors
- Higaki, T., Nakamura, Y., Zhou, J., Yu, Z., Nemoto, T., Tatsugami, F., & Awai, K.
- Venue
- Academic Radiology
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 27
- Issue
- 1
- Pages
- 82-87
- ISSN
- 1076-6332 (ISSN-L)
- OpenAlex
- W2994431743
- Cited by
- 210
- References
- 1
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.