The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Low stiffness porous Ti structures for load-bearing implants
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Recent metallic materials for biomedical applications
Niinomi, M. (2002) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-002-0109-2 · Cited by 1,508
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,391
Design and mechanical properties of new β type titanium alloys for implant materials
Kuroda, D., Niinomi, M., Morinaga, M., Kato, Y., & Yashiro, T. (1998) · Materials Science and Engineering A · doi:10.1016/s0921-5093(97)00808-3 · Cited by 1,323
Park, J. B., & Fung, Y. C. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138215 · Cited by 809
Processing of biocompatible porous Ti and Mg
Wen, C. E., Mabuchi, M., Yamada, Y., Shimojima, K., Chino, Y., & Asahina, T. (2001) · Scripta Materialia · doi:10.1016/s1359-6462(01)01132-0 · Cited by 665
Mechanical properties of porous titanium compacts prepared by powder sintering
Oh, I.-H., Nomura, N., Masahashi, N., & Hanada, S. (2003) · Scripta Materialia · doi:10.1016/j.scriptamat.2003.08.018 · Cited by 569
Biomaterials in total joint replacement
Katti, K. S. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2003.12.002 · Cited by 544
Practical considerations and capabilities for laser assisted direct metal deposition
Lewis, G. K., & Schlienger, E. (2000) · Materials & Design (1980-2015) · doi:10.1016/s0261-3069(99)00078-3 · Cited by 449
Cited by
Epitaxy and Microstructure Evolution in Metal Additive Manufacturing
Basak, A., & Das, S. (2016) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070115-031728 · Cited by 363
The Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201
Metadata
- Authors
- Krishna, B. V., Bose, S., & Bandyopadhyay, A.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2007-11
- Volume
- 3
- Issue
- 6
- Pages
- 997-1006
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2001203834
- Cited by
- 441
- References
- 18
- FWCI
- 33.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low stiffness porous Ti structures for load-bearing implants. https://app.cochat.ai/papers/10.1016/j.actbio.2007.03.008
- The paper
- Krishna, B. V., Bose, S., & Bandyopadhyay, A. (2007). Low stiffness porous Ti structures for load-bearing implants. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2007.03.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.