The DOI matches its Crossref record.
Selective laser sintering of hydroxyapatite/poly-ε-caprolactone scaffolds
Open accessAbstract
Selective laser sintering (SLS) enables the fabrication of complex geometries with the intricate and controllable internal architecture required in the field of tissue engineering. In this study hydroxyapatite and poly-epsilon-caprolactone, considered suitable for hard tissue engineering purposes, were used in a weight ratio of 30:70. The quality of the fabricated parts is influenced by various process parameters. Among them Four parameters, namely laser fill power, outline laser power, scan spacing and part orientation, were identified as important. These parameters were investigated according to a central composite design and a model of the effects of these parameters on the accuracy and mechanical properties of the fabricated parts was developed. The dimensions of the fabricated parts were strongly dependent on the manufacturing direction and scan spacing. Repeatability analysis shows that the fabricated features can be well reproduced. However, there were deviations from the nominal dimensions, with the features being larger than those designed. The compressive modulus and yield strength of the fabricated microstructures with a designed relative density of 0.33 varied between 0.6 and 2.3 and 0.1 and 0.6 MPa, respectively. The mechanical behavior was strongly dependent on the manufacturing direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in 3D printing of biomaterials
Chia, H. N., & Wu, B. M. (2015) · Journal of Biological Engineering · doi:10.1186/s13036-015-0001-4 · Cited by 1,734
New Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048
Laser sintering of polyamides and other polymers
Goodridge, R. D., Tuck, C. J., & Hague, R. J. M. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.04.001 · Cited by 835
Current state of fabrication technologies and materials for bone tissue engineering
Wubneh, A., Tsekoura, E. K., Ayranci, C., & Uludağ, H. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.09.031 · Cited by 584
Additive manufacturing of natural fiber reinforced polymer composites: Processing and prospects
Balla, V. K., Kate, K. H., Satyavolu, J., Singh, P., & Tadimeti, J. G. D. (2019) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2019.106956 · Cited by 580
Metadata
- Authors
- Eosoly, S., Brabazon, D., Lohfeld, S., & Looney, L.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 6
- Issue
- 7
- Pages
- 2511-2517
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2006991257
- Cited by
- 186
- References
- 0
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective laser sintering of hydroxyapatite/poly-ε-caprolactone scaffolds. https://app.cochat.ai/papers/10.1016/j.actbio.2009.07.018
- The paper
- Eosoly, S., Brabazon, D., Lohfeld, S., & Looney, L. (2010). Selective laser sintering of hydroxyapatite/poly-ε-caprolactone scaffolds. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2009.07.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.