The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Compositionally graded doped hydroxyapatite coating on titanium using laser and plasma spray deposition for bone implants
Open accessAbstract
Plasma sprayed hydroxyapatite (HA) coating is known to improve the osteoconductivity of metallic implants. However, the adhesive bond strength of the coating is affected due to a mismatch in coefficients of thermal expansion (CTE) between the metal and the HA ceramic. In this study, a gradient HA coating was prepared on Ti6Al4V by laser engineered net shaping (LENS™) followed by plasma spray deposition. In addition, 1 wt.% MgO and 2 wt.% Ag2O were mixed with HA to improve the biological and antibacterial properties of the coated implant. Results showed that the presence of an interfacial layer by LENS™ enhanced adhesive bond strength from 26 ± 2 MPa for just plasma spray coating to 39 ± 4 MPa for LENS™ and plasma spray coatings. Presence of MgO and Ag2O did not influence the adhesive bond strength. Also, Ag+ ions release dropped by 70% less with a gradient HA LENS™ layer due to enhanced crystallization of the HA layer. In vitro human osteoblast cell culture revealed presence of Ag2O had no deleterious effect on proliferation and differentiation when compared to pure HA as control and provided antibacterial properties against E. coli and S. aureus bacterial strands. This study presents an innovative way to improve interfacial mechanical properties of plasma sprayed HA coating for load-bearing orthopedic implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The relationship of surface roughness and cell response of chemical surface modification of titanium
Zareidoost, A., Yousefpour, M., Ghaseme, B., & Amanzadeh, A. (2012) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-012-4611-9 · Cited by 336
Cited by
Nazir, A., Gokcekaya, O., Md Masum Billah, K., Ertugrul, O., Jiang, J., Sun, J., & Hussain, S. (2023) · Materials & Design · doi:10.1016/j.matdes.2023.111661 · Cited by 773
State of the Art in Directed Energy Deposition: From Additive Manufacturing to Materials Design
Dass, A., & Moridi, A. (2019) · Coatings · doi:10.3390/coatings9070418 · Cited by 667
Alloy design via additive manufacturing: Advantages, challenges, applications and perspectives
Bandyopadhyay, A., Traxel, K. D., Lang, M., Juhasz, M., Eliaz, N., & Bose, S. (2022) · Materials Today · doi:10.1016/j.mattod.2021.11.026 · Cited by 347
Self-citationBioinspired surface modification of orthopedic implants for bone tissue engineering
Hu, C., Ashok, D., Nisbet, D. R., & Gautam, V. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119366 · Cited by 324
Review on Additive Manufacturing of Multi-Material Parts: Progress and Challenges
Hasanov, S., Alkunte, S., Rajeshirke, M., Gupta, A., Huseynov, O., Fidan, I., Alifui-Segbaya, F., & Rennie, A. (2021) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp6010004 · Cited by 258
Metadata
- Authors
- Ke, D., Vu, A. A., Bandyopadhyay, A., & Bose, S.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 84
- Pages
- 414-423
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2902500366
- Cited by
- 177
- References
- 1
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compositionally graded doped hydroxyapatite coating on titanium using laser and plasma spray deposition for bone implants. https://app.cochat.ai/papers/10.1016/j.actbio.2018.11.041
- The paper
- Ke, D., Vu, A. A., Bandyopadhyay, A., & Bose, S. (2019). Compositionally graded doped hydroxyapatite coating on titanium using laser and plasma spray deposition for bone implants. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2018.11.041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.