Ion-substituted calcium phosphate coatings by physical vapor deposition magnetron sputtering for biomedical applications: A review
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Coatings based on ion-substituted calcium phosphate (Ca-P) have attracted great attention in the scientific community over the past decade for the development of biomedical applications. Among such Ca-P based structures, hydroxyapatite (HA) has shown significant influence on cell behaviors including cell proliferation, adhesion, and differentiation. These cell behaviors determine the osseointegration between the implant and host bone and the biocompatibility of implants. This review presents a critical analysis on the physical vapor deposition magnetron sputtering (PVDMS) technique that has been used for ion-substituted Ca-P based coatings on implants materials. The effect of PVDMS processing parameters such as discharge power, bias voltage, deposition time, substrate temperature, and post-heat treatment on the surface properties of ion-substituted Ca-P coatings is elucidated. Moreover, the advantages, short comings and future research directions of Ca-P coatings by PVDMS have been comprehensively analyzed. It is revealed that the topography and surface chemistry of amorphous HA coatings influence the cell behavior, and ion-substituted HA coatings significantly increase cell attachment but may result in a cytotoxic effect that reduces the growth of the cells attached to the coating surface areas. Meanwhile, low-crystalline HA coatings exhibit lower rates of osteogenic cell proliferation as compared to highly crystalline HA coatings developed on Ti based surfaces. PVDMS allows a close reproduction of bioapatite characteristics with high adhesion strength and substitution of therapeutic ions. It can also be used for processing nanostructured Ca-P coatings on polymeric biomaterials and biodegradable metals and alloys with enhanced corrosion resistance and biocompatibility. STATEMENT OF SIGNIFICANCE: Recent studies have utilized the physical vapor deposition magnetron sputtering (PVDMS) for the deposition of Ca-P and ion-substituted Ca-P thin film coatings on orthopedic and dental implants. This review explains the effect of PVDMS processing parameters, such as discharge power, bias voltage, deposition time, substrate temperature, and post-heat treatment, on the surface morphology and crystal structure of ion-substituted Ca-P and ion-substituted Ca-P thin coatings. It is revealed that coating thickness, surface morphology and crystal structure of ion-substituted Ca-P coatings via PVDMS directly affect the biocompatibility and cell responses of such structures. The cell responses determine the osseointegration between the implant and host bone and eventually the success of the implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Kittler, S., Greulich, C., Diendorf, J., Köller, M., & Epple, M. (2010) · Chemistry of Materials · doi:10.1021/cm100023p · Cited by 1,126
Cited by
Montesissa, M., Sassoni, E., Boi, M., Borciani, G., Boanini, E., & Graziani, G. (2024) · Nanomaterials · doi:10.3390/nano14161332 · Cited by 17
Metadata
- Authors
- Qadir, M., Li, Y., & Wen, C.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 89
- Pages
- 14-32
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2921596311
- Cited by
- 189
- References
- 2
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ion-substituted calcium phosphate coatings by physical vapor deposition magnetron sputtering for biomedical applications: A review. https://app.cochat.ai/papers/10.1016/j.actbio.2019.03.006
- The paper
- Qadir, M., Li, Y., & Wen, C. (2019). Ion-substituted calcium phosphate coatings by physical vapor deposition magnetron sputtering for biomedical applications: A review. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2019.03.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.