The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Long-term in vivo study of biodegradable Zn-Cu stent: A 2-year implantation evaluation in porcine coronary artery
Abstract
In the present study, a novel biodegradable Zn-0.8Cu coronary artery stent was fabricated and implanted into porcine coronary arteries for up to 24 months. Micro-CT analysis showed that the implanted stent was able to maintain structural integrity after 6 months, while its disintegration occurred after 9 months of implantation. After 24 months of implantation, approximately 28±13 vol.% of the stent remained. Optical coherence tomography and histological analysis showed that the endothelialization process could be completed within the first month after implantation, and no inflammation responses or thrombosis formation was observed within 24 months. Cross-section analysis indicated that the subsequent degradation products had been removed in the abluminal direction, guaranteeing that the strut could be replaced by normal tissue without the risk of contaminating the circulatory system, causing neither thrombosis nor inflammation response. The present work demonstrates that the Zn-0.8Cu stent has provided sufficient structural supporting and exhibited an appropriate degradation rate during 24 months of implantation without degradation product accumulation, thrombosis, or inflammation response. The results indicate that the Zn-0.8Cu coronary artery stent is promising for further clinical applications. Statement of significance Although Zn and its alloys have been considered to be potential candidates of biodegradable metals for vascular stent use, by far there is no Zn-based stent with proper medical device performance has been reported because of the low mechanical properties of zinc. The present work describes promising results about a Zn-Cu biodegradable vascular stent in porcine coronary arteries. The Zn-Cu stent fabricated in this work obtained a quite well medical device performance both in vitro and in vivo, and degraded with a proper rate without safety problems induced. Furthermore, large animal models have more cardiovascular similarities to humans. Results of this study may provide further information for the translational medicine research of the Zn-based stents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Copper-induced vascular endothelial growth factor expression and wound healing
Sen, C. K., Khanna, S., Venojarvi, M., Trikha, P., Ellison, E. C., Hunt, T. K., & Roy, S. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01015.2001 · Cited by 522
Vascular calcification: Mechanisms of vascular smooth muscle cell calcification
Leopold, J. A. (2015) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2014.10.021 · Cited by 468
Large animal models of cardiovascular disease
Tsang, H. G., Rashdan, N. A., Whitelaw, C. B. A., Corcoran, B. M., Summers, K. M., & MacRae, V. E. (2016) · Cell Biochemistry and Function · doi:10.1002/cbf.3173 · Cited by 154
Cited by
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Metadata
- Authors
- Zhou, C., Li, H.-F., Yin, Y.-X., Shi, Z.-Z., Li, T., Feng, X.-Y., Zhang, J.-W., Song, C.-X., Cui, X.-S., Xu, K.-L., Zhao, Y.-W., Hou, W.-B., Lu, S.-T., Liu, G., Li, M.-Q., Ma, J.-Y., Toft, E., Volinsky, A. A., Wan, M., Yao, X.-J., Wang, C.-B., Yao, K., Xu, S.-K., Lu, H., Chang, S.-F., Ge, J.-B., Wang, L.-N., & Zhang, H.-J.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 97
- Pages
- 657-670
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2967287193
- Cited by
- 171
- References
- 3
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term in vivo study of biodegradable Zn-Cu stent: A 2-year implantation evaluation in porcine coronary artery. https://app.cochat.ai/papers/10.1016/j.actbio.2019.08.012
- The paper
- Zhou, C., Li, H.-F., Yin, Y.-X., Shi, Z.-Z., Li, T., Feng, X.-Y., Zhang, J.-W., Song, C.-X., Cui, X.-S., Xu, K.-L., Zhao, Y.-W., Hou, W.-B., Lu, S.-T., Liu, G., Li, M.-Q., Ma, J.-Y., Toft, E., Volinsky, A. A., Wan, M., . . . Zhang, H.-J. (2019). Long-term in vivo study of biodegradable Zn-Cu stent: A 2-year implantation evaluation in porcine coronary artery. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2019.08.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.