Evaluation of an octyl group-modified Alaska pollock gelatin-based surgical sealant for prevention of postoperative adhesion
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Postoperative adhesion can lead to an increase in the number of surgeries required, longer operation times, and high medical costs, resulting in the quality of life of the patient being lowered. To address these clinical problems, we developed a surgical sealant with anti-adhesion properties for the prevention of postoperative adhesion following application to the large intestine surface. The developed sealant was composed of octyl (C8) group-modified Alaska pollock-derived gelatin (C8-ApGltn) and a poly(ethylene)glycol-based 4-armed crosslinker (4S-PEG) (C8-ApGltn/4S-PEG sealant). Hydrophobic modification of the ApGltn molecule with C8 groups effectively enhanced both the burst strength on the large intestine surface and the bulk modulus. An in vitro anti-adhesion test indicated that cured C8-ApGltn/4S-PEG sealant adhered to the large intestine surface showed low adhesive strength compared with commercial anti-adhesion film. Besides, cured C8-ApGltn/4S-PEG sealant effectively inhibited albumin permeation and penetration of L929 fibroblasts. In vivo experiments using a rat peritoneal anti-adhesion model showed that C8-ApGltn/4S-PEG sealant acted as a sealing barrier on the target cecum surface and also provided an anti-adhesion barrier to prevent postoperative adhesion between the peritoneum and cecum. C8-ApGltn/4S-PEG sealant showed sufficient cytocompatibility and biodegradability and therefore has potential for use in gastroenterological surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
“Nonswellable” Hydrogel Without Mechanical Hysteresis
Kamata, H., Akagi, Y., Kayasuga-Kariya, Y., Chung, U.-I., & Sakai, T. (2014) · Science · doi:10.1126/science.1247811 · Cited by 669
Halper, J., & Kjaer, M. (2014) · Advances in Experimental Medicine and Biology · doi:10.1007/978-94-007-7893-1_3 · Cited by 532
Cited by
Akhlaghi, S., Ebrahimnia, M., Niaki, D. S., Solhi, M., Rabbani, S., & Haeri, A. (2023) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2023.104539 · Cited by 25
Ding, Z., Liang, Z., Rong, X., Fu, X., Fan, J., Lai, Y., Cai, Y., Huang, C., Li, L., Tang, G., et al. (2024) · Small · doi:10.1002/smll.202403753 · Cited by 22
Erdi, M., Saruwatari, M. S., Rozyyev, S., Acha, C., Ayyub, O. B., Sandler, A. D., & Kofinas, P. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c00283 · Cited by 15
Metadata
- Authors
- Mizuta, R., Mizuno, Y., Chen, X., Kurihara, Y., & Taguchi, T.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 121
- Pages
- 328-338
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W3111640238
- Cited by
- 41
- References
- 2
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of an octyl group-modified Alaska pollock gelatin-based surgical sealant for prevention of postoperative adhesion. https://app.cochat.ai/papers/10.1016/j.actbio.2020.12.025
- The paper
- Mizuta, R., Mizuno, Y., Chen, X., Kurihara, Y., & Taguchi, T. (2021). Evaluation of an octyl group-modified Alaska pollock gelatin-based surgical sealant for prevention of postoperative adhesion. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2020.12.025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.