Cited by 15Intestinal and Peritoneal AdhesionsElectrospun Nanofibers in Biomedical ApplicationsSurgical Sutures and Adhesives

Controlled Release of a Therapeutic Peptide in Sprayable Surgical Sealant for Prevention of Postoperative Abdominal Adhesions

Open access
Erdi, Metecan, Saruwatari, Michele S., Rozyyev, Selim, Acha, Christopher, Ayyub, Omar B., Sandler, Anthony D., Kofinas, Peter·2023·ACS Applied Materials & Interfaces

Abstract

Formation of asymmetric, rigid scar tissue known as surgical adhesions is caused by traumatic disruption of mesothelial-lined surfaces in surgery. A widely adopted prophylactic barrier material (Seprafilm) for the treatment of intra-abdominal adhesions is applied operatively as a pre-dried hydrogel sheet but has reduced translational efficacy due its brittle mechanical properties. Topically administered peritoneal dialysate (Icodextrin) and anti-inflammatory drugs have failed to prevent adhesions due to an uncontrolled release profile. Hence, inclusion of a targeted therapeutic into a solid barrier host matrix with improved mechanical properties could provide dual utility in adhesion prevention and as a surgical sealant. Spray deposition of poly(lactide- co -caprolactone) (PLCL) polymer fibers through solution blow spinning has yielded a tissue-adherent barrier material with previously reported adhesion prevention efficacy due to a surface erosion mechanism that inhibits deposition of inflamed tissue. However, such an approach uniquely presents an avenue for controlled therapeutic release through mechanisms of diffusion and degradation. Such a rate is kinetically tuned via facile blending of “high” molecular weight (HMW) and “low” molecular weight (LMW) PLCL with slow and fast biodegradation rates, respectively. Here, we explore viscoelastic blends of HMW PLCL (70% w/v) and LMW PLCL (30% w/v) as a host matrix for anti-inflammatory drug delivery. In this work, COG133, an apolipoprotein E (ApoE) mimetic peptide with potent anti-inflammatory properties was selected and tested. In vitro studies with PLCL blends presented low (∼30%) and high (∼80%) percent release profiles over a 14-day period based on the nominal molecular weight of the HMW PLCL component. Two independent mouse models of cecal ligation and cecal anastomosis significantly reduced adhesion severity versus Seprafilm, COG133 liquid suspension, and no treatment control. The synergy of physical and chemical methods in a barrier material with proven preclinical studies highlights the value of COG133-loaded PLCL fiber mats in effectively dampening the formation of severe abdominal adhesions.

Integrity signals

Registry

Crossref · 10.1021/acsami.3c00283

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Fibers fabricated via solution blow spinning exhibit minimal solvent residues, have diameters ranging from the nanoscale to the microscale, and PLCL materials can be fabricated into various scaffolds via solution blow spinning for diverse biomedical fields.

    “The results showed that fibers fabricated via the SBS method exhibit minimal solvent residues, the fiber scaffolds had diameters ranging from the nanoscale to the microscale, and PLCL materials could be fabricated into various scaffolds via the SBS method for applications in diverse biomedical fields [84–87].”
  • PLCL fibrous membranes fabricated via SBS enable precise controllable modulation of release behavior of anti-inflammatory agent COG133, and drug-loaded PLCL fibrous membranes exhibit excellent anti-adhesion efficacy in animal models of abdominal adhesions.

    “Metecan Erdi et al. fabricated PLCL fibrous membranes via SBS, which enables the precise controllable modulation of the release behavior of the anti-inflammatory agent COG133. The drug-loaded PLCL fibrous membranes exhibited excellent anti-adhesion efficacy in animal models of abdominal adhesions [86].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Erdi, M., Saruwatari, M. S., Rozyyev, S., Acha, C., Ayyub, O. B., Sandler, A. D., & Kofinas, P.
Affiliations
  • University of Maryland, College Park (US)
  • Children's National (US)
  • Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, Maryland 20742, United States
Corresponding author
  • Sandler, Anthony D.
  • Kofinas, Peter
Venue
ACS Applied Materials & Interfaces
Published
2023-03-08
Volume
15
Issue
11
Pages
14089-14098
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W4323533341
Cited by
15
References
2
Citations by year
2026: 2 · 2025: 4 · 2024: 6 · 2023: 3
FWCI
3.78
Type
journal article
Language
en
Open access
Locations
  • ACS Applied Materials & Interfaces (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institute of Diabetes and Digestive and Kidney Diseases (F31DK129021)
  • National Institute of General Medical Sciences (R01GM141132)
Topics
  • Health Sciences › Medicine › Surgery › Intestinal and Peritoneal Adhesions
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
Keywords
postoperative peritoneal adhesions, controlled drug release, solution blow spinning, spray deposition, surgical sealants, anti-inflammatory drug delivery, biodegradation rate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review