Cited by 474Non-Invasive Vital Sign MonitoringAtrial Fibrillation Management and OutcomesMobile Health and mHealth Applications

Rationale and design of a large-scale, app-based study to identify cardiac arrhythmias using a smartwatch: the apple heart study

Open access
Turakhia, Mintu P., Desai, Manisha, Hedlin, Haley, Rajmane, Amol, Talati, Nisha, Ferris, Todd, Desai, Sumbul, Nag, Divya +8 more·2019·American Heart Journal

Abstract

BACKGROUND: Smartwatch and fitness band wearable consumer electronics can passively measure pulse rate from the wrist using photoplethysmography (PPG). Identification of pulse irregularity or variability from these data has the potential to identify atrial fibrillation or atrial flutter (AF, collectively). The rapidly expanding consumer base of these devices allows for detection of undiagnosed AF at scale. METHODS: The Apple Heart Study is a prospective, single arm pragmatic study that has enrolled 419,093 participants (NCT03335800). The primary objective is to measure the proportion of participants with an irregular pulse detected by the Apple Watch (Apple Inc, Cupertino, CA) with AF on subsequent ambulatory ECG patch monitoring. The secondary objectives are to: 1) characterize the concordance of pulse irregularity notification episodes from the Apple Watch with simultaneously recorded ambulatory ECGs; 2) estimate the rate of initial contact with a health care provider within 3 months after notification of pulse irregularity. The study is conducted virtually, with screening, consent and data collection performed electronically from within an accompanying smartphone app. Study visits are performed by telehealth study physicians via video chat through the app, and ambulatory ECG patches are mailed to the participants. CONCLUSIONS: The results of this trial will provide initial evidence for the ability of a smartwatch algorithm to identify pulse irregularity and variability which may reflect previously unknown AF. The Apple Heart Study will help provide a foundation for how wearable technology can inform the clinical approach to AF identification and screening.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ahj.2018.09.002

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Apple Heart Study, with 400,000 subjects, demonstrated the power of wearable devices to detect atrial fibrillation using a photoplethysmographic signal in a large group of patients.

    “The Apple Heart Study, with its study size of 40 0,0 0 0 subjects and its ability to detect atrial fibrillation using a photophlethysmographic signal, demonstrated the power of wearable devices to detect rhythm abnormalities in a large group of patients [35] .”

    From Evaluating and managing bradycardia (2020) · cites this paper as [35]

    The Summary describes a study of over 400,000 participants, and the Discussion says it evaluates photoplethysmography-based screening for pulse irregularity that may reveal AF. But this is a rationale-and-design paper: the Summary says the results *will* provide an initial evaluation. It does not report that the study had already demonstrated successful AF detection. (LLM, conf=0.90)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 19

  1. [1]Benjamin EJ, Virani SS, Callaway CW, Heart Disease and Stroke Statistics-2018 Update: A Report From the American Heart Association. Circulation 2018; 137(12): e67– 492. 29386200
  2. [2]January CT, Wann LS, Alpert JS, 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol 2014; 64(21): e1– 76. 24685669
  3. [4]Wolf PA, Abbott RD, Kannel WB. Atrial fibrillation as an independent risk factor for stroke: the Framingham Study. Stroke 1991; 22(8): 983– 8. 1866765
  4. [7]Lin HJ, Wolf PA, Benjamin EJ, Newly diagnosed atrial fibrillation and acute stroke. The Framingham Study. Stroke 1995 9; 26(9): 1527– 30. 7660392
  5. [8]Turakhia MP, Shafrin J, Bognar K, Estimated prevalence of undiagnosed atrial fibrillation in the United States. PLoS ONE 2018; 13(4), e0195088. 29649277 PMC5896911
  6. [9]Turakhia MP, Shafrin J, Bognar K, Economic Burden of Undiagnosed Nonvalvular Atrial Fibrillation in the United States. Am J Cardiol 2015; 116(5): 733– 9. 26138378
  7. [11]King DR, Mehta ND, Gehi AK, Minimally symptomatic atrial fibrillation patients derive significant symptom relief following rate control or rhythm control therapy. J Clin Med Res 2015; 7(9): 690– 3. 26251683 PMC4522986
  8. [12]Wong JA, Conen D, Van Gelder IC, Progression of device-detected subclinical atrial fibrillation and the risk of heart failure. J Am Coll Cardiol 2018; 71(23): 2603– 11. 29880119
  9. [13]Marrouche NF, Brachmann J, Andresen D, Catheter ablation for atrial fibrillation with heart failure. N Engl J Med 2018; 378(5): 417– 27. 29385358
  10. [14]Di Biase L, Mohanty P, Mohanty S, Ablation versus amiodarone for treatment of persistent atrial fibrillation in patients with congestive heart failure and an implanted device: results from the AATAC multicenter randomized trial. Circulation 2016; 133(17): 1637– 44. 27029350
  11. [15]Freedman B, Camm J, Calkins H, Screening for atrial fibrillation: a report of the AF-SCREEN International Collaboration. Circulation 2017; 135(19): 1851– 67. 28483832
  12. [16]Lowres N, Neubeck L, Salkeld G, Feasibility and cost-effectiveness of stroke prevention through community screening for atrial fibrillation using iPhone ECG in pharmacies. The SEARCH-AF study. Thromb Haemost 2014; 111(6): 1167– 76. 24687081
  13. [17]Turakhia MP, Ullal AJ, Hoang DD, Feasibility of extended ambulatory electrocardiogram monitoring to identify silent atrial fibrillation in high-risk patients: the Screening Study for Undiagnosed Atrial Fibrillation (STUDY-AF). Clin Cardiol 2015; 38(5): 285– 92. 25873476 PMC4654330
  14. [20]Reiffel JA, Verma A, Kowey PR, Incidence of previously undiagnosed atrial fibrillation using insertable cardiac monitors in a high-risk population: The REVEAL AF study. JAMA Cardiol 2017; 2(10): 1120– 7. 28842973 PMC5710506
  15. [21]Sanna T, Diener H-C, Passman RS, Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med 2014; 370(26): 2478– 86. 24963567
  16. [22]US Preventive Services Task Force. Screening for atrial fibrillation with electrocardiography: Us preventive services task force recommendation statement. JAMA 2018; 320(5): 478– 84. 30088016
  17. [26]Sun J, Chernick MR, LaBudde RA. A bootstrap test for comparing two variances: simulation of size and power in small samples. J Biopharm Stat 2011; 21(6): 1079– 93. 22023677
  18. [27]Tison GH, Sanchez JM, Ballinger B, Passive detection of atrial fibrillation using a commercially available smartwatch. JAMA Cardiol 2018; 3(5): 409– 16. 29562087 PMC5875390
  19. [28]Califf RM, Sugarman J. Exploring the ethical and regulatory issues in pragmatic clinical trials. Clin Trials 2015; 12(5): 436– 41. 26374676 PMC4891194

Cited by

Sorted by citations

Authors
Turakhia, M. P., Desai, M., Hedlin, H., Rajmane, A., Talati, N., Ferris, T., Desai, S., Nag, D., Patel, M., Kowey, P., Rumsfeld, J. S., Russo, A. M., Hills, M. T., Granger, C. B., Mahaffey, K. W., & Perez, M. V.
Affiliations
  • VA Palo Alto Health Care System (US)
  • Stanford University (US)
  • Apple (United States) (US)
  • Lankenau Heart Institute (US)
  • University of Colorado Anschutz (US)
  • Cooper Medical School of Rowan University (US)
  • StopAfib.org (US)
  • Duke University (US)
  • Stanford Medicine (US)
Corresponding author
  • Turakhia, Mintu P.
  • Perez, Marco V.
Venue
American Heart Journal
Publisher
Elsevier BV
Published
2019-01
Volume
207
Pages
66-75
ISSN
0002-8703 (ISSN-L)
OpenAlex
W2899314245
Cited by
474
References
7
Citations by year
2026: 33 · 2025: 65 · 2024: 42 · 2023: 50 · 2022: 60 · 2021: 81 · 2020: 75 · 2019: 65 · 2018: 1 · 2016: 1 · 2012: 1
FWCI
22.19
Type
journal article
Language
en
Open access
Locations
  • American Heart Journal (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion, cc-by-nc-nd)
Funders
  • Medtronic
  • Bayer Fund
  • National Institutes of Health
  • Gilead Sciences
  • Medtronic Foundation
  • National Heart, Lung, and Blood Institute
  • AbbVie
  • Luitpold Pharmaceuticals
  • American Heart Association
  • Duke University
  • Janssen Pharmaceuticals
  • Sanofi
  • Merck Sharp and Dohme
  • Bristol-Myers Squibb
  • Biosense Webster
  • AstraZeneca
  • CSL Behring
  • GlaxoSmithKline
  • Boston Scientific Corporation
  • Novartis
  • Apple
  • Duke Clinical Research Institute
  • Biotronik
  • Abbott Laboratories
  • AtriCure
  • Boehringer Ingelheim
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
Keywords
atrial fibrillation, atrial flutter, Apple Watch, smartwatches, wearable devices, photoplethysmography, pulse irregularity, Holter monitoring, telemedicine, mobile application, undiagnosed atrial fibrillation
MeSH terms
Smartphone, Patient Reported Outcome Measures, Wearable Electronic Devices, Algorithms, Atrial Fibrillation, Atrial Flutter, Humans, Patient Acceptance of Health Care, Prospective Studies, Time Factors, Electrocardiography, Ambulatory, Telemedicine, Mobile Applications, Pragmatic Clinical Trials as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review