Cited by 47Neuroscience and Neural EngineeringPain Management and TreatmentTactile and Sensory Interactions

Long-term Repeatability and Reproducibility of Phosphene Characteristics in Chronically Implanted Argus II Retinal Prosthesis Subjects

Luo, Yvonne H-L., Zhong, Joe Jiangjian, Clemo, Monica, da Cruz, Lyndon·2016·American Journal of Ophthalmology

Abstract

Purpose Previously published literatures of acute studies on few subjects have shown contradictory evidence on the reproducibility and characteristics of the elicited phosphenes, despite using the same stimulating parameters with epiretinal electrode arrays. In this study, we set out to investigate the long-term repeatilibity and reproducibility of phosphenes in subjects chronically implanted with the Argus II retinal prosthesis (Second Sight Medical Products, Inc., Sylmar, CA, USA).Design Retrospective interventional case series and reliability study.Methods Six Argus II subjects of >5 years implantation from a single site participated. The 4-electrode cluster ("quad") closest to fovea was stimulated in each subject with a fixed biphasic current. Perceived phosphenes were depicted relative to subjective visual field center. The stimulus was applied at reducing time intervals from 20 minutes to 1 second. Two sets of stimulations were performed on the same day and 2 further sets repeated on a separate visit >1 week apart.Results Each subject depicted phosphenes of consistent shapes and sizes, and reported seeing the same colors with the fixed stimulating parameters, irrespective of the interstimuli intervals. However, there is a wide intersubject variation in the phosphene characteristics. Four subjects drew phosphenes in the same visual field quadrant, as predicted by the quad-fovea location. Two subjects depicted phosphenes in the same hemifield as the expected locations.Conclusion Phosphenes for each subject were consistently reproducible in all our chronically implanted subjects. This has important implications in the development of long-term pixelated prosthetic vision for future devices.

Integrity signals

Registry

Crossref · 10.1016/j.ajo.2016.07.021

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Since the goal is not primarily to create natural vision, it suffices that phosphene characteristics are distinct and stable over time, which is the case for current implants.

    “However, since the goal is not primarily to create natural vision, it suffices that phosphene characteristics are distinct and stable over time, which is the case for current implants (Luo et al., 2016; Fernández et al., 2021).”
  • Phosphene shapes and sizes differ between electrodes and across participants.

    “Since phosphene shapes and sizes differ between electrodes and across participants (D. Nanduri et al. 2008; Beyeler et al. 2019; Luo et al. 2016), which could influence the overall image produced by multi-electrode stimulation, we performed a systematic mapping experiment.”
  • Phosphene appearance varied greatly across electrodes and participants.

    “The appearance of phosphenes was highly variable across electrodes and participants, which is consistent with prior studies (D. Nanduri et al. 2008; Beyeler et al. 2019; Luo et al. 2016).”

The citation lists haven’t been fetched yet

References 13 · Cited by 47

Authors
Luo, Y. H.-L., Zhong, J. J., Clemo, M., & da Cruz, L.
Affiliations
Moorfields Eye Hospital NHS Foundation Trust (GB)
Corresponding author
Luo, Yvonne H-L.
Venue
American Journal of Ophthalmology
Publisher
Elsevier BV
Published
2016-10
Volume
170
Pages
100-109
ISSN
0002-9394 (ISSN-L)
OpenAlex
W2485864648
Cited by
47
References
13
Citations by year
2026: 1 · 2025: 5 · 2024: 3 · 2023: 7 · 2022: 10 · 2021: 7 · 2020: 3 · 2019: 4 · 2018: 2 · 2017: 5
FWCI
2.06
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
Argus II retinal prosthesis, phosphenes, reproducibility, chronic implantation, visual field mapping, interstimulus interval, interindividual variability
MeSH terms
Aged, Electrodes, Implanted, Humans, Middle Aged, Phosphenes, Retinitis Pigmentosa, Retrospective Studies, Vision Disorders, Visual Perception, Reproducibility of Results, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review