Automated Segmentation of Lesions Including Subretinal Hyperreflective Material in Neovascular Age-related Macular Degeneration
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE To evaluate an automated segmentation algorithm with a convolutional neural network (CNN) to quantify and detect intraretinal fluid (IRF), subretinal fluid (SRF), pigment epithelial detachment (PED), and subretinal hyperreflective material (SHRM) through analyses of spectral-domain optical coherence tomography (SD-OCT) images from patients with neovascular age-related macular degeneration (nAMD). DESIGN Reliability and validity analysis of a diagnostic tool. METHODS We constructed a dataset including 930 B-scans from 93 eyes of 93 patients with nAMD. A CNN-based deep neural network was trained using 11 550 augmented images derived from 550 B-scans. The performance of the trained network was evaluated using a validation set including 140 B-scans and a test set of 240 B-scans. The Dice coefficient, positive predictive value (PPV), sensitivity, relative area difference (RAD), and intraclass correlation coefficient (ICC) were used to evaluate segmentation and detection performance. RESULTS Good agreement was observed for both segmentation and detection of lesions between the trained network and clinicians. The Dice coefficients for segmentation of IRF, SRF, SHRM, and PED were 0.78, 0.82, 0.75, and 0.80, respectively; the PPVs were 0.79, 0.80, 0.75, and 0.80, respectively; and the sensitivities were 0.77, 0.84, 0.73, and 0.81, respectively. The RADs were -4.32%, -10.29%, 4.13%, and 0.34%, respectively, and the ICCs were 0.98, 0.98, 0.97, and 0.98, respectively. All lesions were detected with high PPVs (range 0.94-0.99) and sensitivities (range 0.97-0.99). CONCLUSIONS A CNN-based network provides clinicians with quantitative data regarding nAMD through automatic segmentation and detection of pathologic lesions, including IRF, SRF, PED, and SHRM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Brain Tumor Segmentation Using Convolutional Neural Networks in MRI Images
Pereira, S., Pinto, A., Alves, V., & Silva, C. A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2538465 · Cited by 2,735
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Jaffe, G. J., Martin, D. F., Toth, C. A., Daniel, E., Maguire, M. G., Ying, G.-S., Grunwald, J. E., & Huang, J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.01.073 · Cited by 294
Cited by
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
“Lee et al. proposed a U-Net architecture that simultaneously segments several relevant lesions of neovascular AMD (IRF, SRF, PED, and SHRM) on OCT scans, with a sensitivity of at least 0.97 (Lee et al., 2018b).”
BackgroundResultInfluentialExploiting epistemic uncertainty of anatomy segmentation for anomaly detection in retinal OCT
Seebock, P., Orlando, J. I., Schlegl, T., Waldstein, S. M., Bogunovic, H., Klimscha, S., Langs, G., & Schmidt-Erfurth, U. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2919951 · Cited by 164
“for segmentation of fluid [9], [10], drusen [11], hyperreflective material [12] or photoreceptor”
BackgroundRetinal specialist versus artificial intelligence detection of retinal fluid from OCT
Keenan, T. D. L., Clemons, T. E., Domalpally, A., Elman, M. J., Havilio, M., Agrón, E., Benyamini, G., & Chew, E. Y. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.06.038 · Cited by 93
Metadata
- Authors
- Lee, H., Kang, K. E., Chung, H., & Kim, H. C.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 191
- Pages
- 64-75
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W2797401432
- Cited by
- 58
- References
- 5
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Segmentation of Lesions Including Subretinal Hyperreflective Material in Neovascular Age-related Macular Degeneration. https://app.cochat.ai/papers/10.1016/j.ajo.2018.04.007
- The paper
- Lee, H., Kang, K. E., Chung, H., & Kim, H. C. (2018). Automated Segmentation of Lesions Including Subretinal Hyperreflective Material in Neovascular Age-related Macular Degeneration. American Journal of Ophthalmology. https://doi.org/10.1016/j.ajo.2018.04.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.