CoChat

Enhanced Tomographic Assessment to Detect Corneal Ectasia Based on Artificial Intelligence

Lopes, Bernardo T., Ramos, Isaac C., Salomão, Marcella Q., Guerra, Frederico P., Schallhorn, Steve C., Schallhorn, Julie M., Vinciguerra, Riccardo, Vinciguerra, Paolo, Price, Francis W., Price, Marianne O., Reinstein, Dan Z., Archer, Timothy J., Belin, Michael W., Machado, Aydano P., Ambrósio, Renato · 2018 · American Journal of Ophthalmology
Cited by 205

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

PURPOSE To improve the detection of corneal ectasia susceptibility using tomographic data. DESIGN Multicenter case-control study. METHODS Data from patients from 5 different clinics from South America, the United States, and Europe were evaluated. Artificial intelligence (AI) models were generated using Pentacam HR (Oculus, Wetzlar, Germany) parameters to discriminate the preoperative data of 3 groups: stable laser-assisted in situ keratomileusis (LASIK) cases (2980 patients with minimum follow-up of 7 years), ectasia susceptibility (71 eyes of 45 patients that developed post-LASIK ectasia [PLE]), and clinical keratoconus (KC; 182 patients). Model accuracy was independently tested in a different set of stable LASIK cases (298 patients with minimum follow-up of 4 years) and in 188 unoperated patients with very asymmetric ectasia (VAE); these patients presented normal topography (VAE-NT) in 1 eye and clinically diagnosed ectasia in the other (VAE-E). Accuracy was evaluated with ROC curves. RESULTS The random forest (RF) provided highest accuracy among AI models in this sample with 100% sensitivity for clinical ectasia (KC+VAE-E; cutoff 0.52), being named Pentacam Random Forest Index (PRFI). Considering all cases, the PRFI had an area under the curve (AUC) of 0.992 (94.2% sensitivity, 98.8% specificity; cutoff 0.216), being statistically higher than the Belin/Ambrósio deviation (BAD-D; AUC = 0.960, 87.3% sensitivity, 97.5% specificity; P = .006, DeLong's test). The optimized cutoff of 0.125 provided sensitivity of 85.2% for VAE-NT and 80% for PLE, with 96.6% specificity. CONCLUSION The PRFI enhances ectasia diagnosis. Further integrations with corneal biomechanical parameters and with the corneal impact from laser vision correction are needed for assessing ectasia risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajo.2018.08.005

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 205

Metadata

Authors
Lopes, B. T., Ramos, I. C., Salomão, M. Q., Guerra, F. P., Schallhorn, S. C., Schallhorn, J. M., Vinciguerra, R., Vinciguerra, P., Price, F. W., Price, M. O., Reinstein, D. Z., Archer, T. J., Belin, M. W., Machado, A. P., & Ambrósio, R.
Venue
American Journal of Ophthalmology
Publisher
Elsevier BV
Published
2018-11
Volume
195
Pages
223-232
ISSN
0002-9394 (ISSN-L)
OpenAlex
W2886173263
Cited by
205
References
15
FWCI
12.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced Tomographic Assessment to Detect Corneal Ectasia Based on Artificial Intelligence. https://app.cochat.ai/papers/10.1016/j.ajo.2018.08.005
The paper
Lopes, B. T., Ramos, I. C., Salomão, M. Q., Guerra, F. P., Schallhorn, S. C., Schallhorn, J. M., Vinciguerra, R., Vinciguerra, P., Price, F. W., Price, M. O., Reinstein, D. Z., Archer, T. J., Belin, M. W., Machado, A. P., & Ambrósio, R. (2018). Enhanced Tomographic Assessment to Detect Corneal Ectasia Based on Artificial Intelligence. American Journal of Ophthalmology. https://doi.org/10.1016/j.ajo.2018.08.005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.