The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Computer-Assisted Corneal Topography in Keratoconus
Abstract
ABSTRACT: Using a computer-assisted videokeratoscope, we determined the topographic findings of 14 eyes of 10 patients with keratoconus. None of these patients had worn contact lenses for at least one year prior to examination and were thus free of contact lens-induced topographical alterations. Two patterns commonly seen included inferior steepening more prominent temporally, and central steepening with a superimposed asymmetric bowtie pattern. When compared with normal eyes three quantitative parameters were significantly different (p <0.001): central corneal power, difference in corneal power between fellow eyes in the same patients, and steepening of the interior cornea compared with the superior cornea. Study of the topography in keratoconus using this technique may prove useful for documenting the pattern of involvement of the anterior corneal surface and providing new insights into the pathogenesis of this condition. [Refractive and Corneal Surgery 1989; 6:400-408].
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keratoconus and related noninflammatory corneal thinning disorders
Krachmer, J. H., Feder, R. S., & Belin, M. W. (1984) · Survey of Ophthalmology · doi:10.1016/0039-6257(84)90094-8 · Cited by 1,598
(1959) · Archives of Ophthalmology · doi:10.1001/archopht.1959.00940091012017 · Cited by 219
The Topography of Normal Corneas
Dingeldein, S. A. (1989) · Archives of Ophthalmology · doi:10.1001/archopht.1989.01070010526024 · Cited by 149
Cited by
Rabinowitz, Y. S. (1998) · Survey of Ophthalmology · doi:10.1016/s0039-6257(97)00119-7 · Cited by 2,744
Self-citationAmbrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.06.025 · Cited by 451
The Genetic and Environmental Factors for Keratoconus
Gordon-Shaag, A., Millodot, M., Shneor, E., & Liu, Y. (2015) · BioMed Research International · doi:10.1155/2015/795738 · Cited by 428
Genetic epidemiological study of keratoconus: Evidence for major gene determination
Wang, Y., Rabinowitz, Y. S., Rotter, J. I., & Yang, H. (2000) · American Journal of Medical Genetics · doi:10.1002/1096-8628(20000828)93:5<403::aid-ajmg11>3.0.co;2-a · Cited by 278
Self-citationQuantitative Descriptors of Corneal Topography: A Clinical Study
Wilson, S. E. (1991) · Archives of Ophthalmology · doi:10.1001/archopht.1991.01080030051037 · Cited by 272
Metadata
- Authors
- Rabinowitz, Y. S., & McDonnell, P. J.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 1989-11
- Volume
- 5
- Issue
- 6
- Pages
- 400-408
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W94146994
- Cited by
- 395
- References
- 3
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer-Assisted Corneal Topography in Keratoconus. https://app.cochat.ai/papers/10.3928/1081-597x-19891101-10
- The paper
- Rabinowitz, Y. S., & McDonnell, P. J. (1989). Computer-Assisted Corneal Topography in Keratoconus. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-19891101-10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.