The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Has Invisalign improved? A prospective follow-up study on the efficacy of tooth movement with Invisalign
Open accessAbstract
INTRODUCTION: The purpose of this research was to provide an update on the accuracy of tooth movement with Invisalign (Align Technology, Santa Clara, Calif). METHODS: This prospective clinical study included 38 patients treated with Invisalign Full or Invisalign Teen. All teeth, from the central incisor to the second molar, were measured on digital models created from intraoral scans. Predicted values were determined by superimposing the initial and final ClinCheck models, and achieved values were determined by superimposing the initial ClinCheck models and the digital models from the posttreatment scans. Individual teeth were superimposed with a best-fit analysis and measured using Compare software (version 8.1; GeoDigm, Falcon Heights, Minn). The types of tooth movements studied were a mesial-distal crown tip, buccal-lingual crown tip, extrusion, intrusion, and mesial-distal rotation. RESULTS: The mean accuracy of Invisalign for all tooth movements was 50%. The highest overall accuracy was achieved with a buccal-lingual crown tip (56%), whereas the lowest overall accuracy occurred with rotation (46%). The accuracies for mesial rotation of the mandibular first molar (28%), distal rotation of the maxillary canine (37%), and intrusion of the mandibular incisors (35%) were particularly low. CONCLUSIONS: There was a marked improvement in the overall accuracy; however, the strengths and weaknesses of tooth movement with Invisalign remained relatively the same.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kravitz, N. D., Kusnoto, B., BeGole, E., Obrez, A., & Agran, B. (2009) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2007.05.018 · Cited by 703
Self-citationSimon, M., Keilig, L., Schwarze, J., Jung, B. A., & Bourauel, C. (2014) · BMC Oral Health · doi:10.1186/1472-6831-14-68 · Cited by 428
Djeu, G., Shelton, C., & Maganzini, A. L. (2005) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.06.002 · Cited by 368
Accuracy of clear aligners: A retrospective study of patients who needed refinement
Charalampakis, O., Iliadi, A., Ueno, H., Oliver, D. R., & Kim, K. B. (2018) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2017.11.028 · Cited by 235
How accurate is Invisalign in nonextraction cases? Are predicted tooth positions achieved?
Grünheid, T., Loh, C. T., & Larson, B. E. (2017) · The Angle Orthodontist · doi:10.2319/022717-147.1 · Cited by 227
Management of overbite with the Invisalign appliance
Khosravi, R., Cohanim, B., Hujoel, P., Daher, S., Neal, M., Liu, W., & Huang, G. (2017) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2016.09.022 · Cited by 203
The treatment effects of Invisalign orthodontic aligners
LAGRAVÈRE, M. O., & FLORES-MIR, C. (2005) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2005.0117 · Cited by 191
Kravitz, N. D., Kusnoto, B., Agran, B., & Viana, G. (2008) · The Angle Orthodontist · doi:10.2319/0003-3219(2008)078[0682:ioaair]2.0.co;2 · Cited by 165
Self-citationInvisalign® treatment in the anterior region
Krieger, E., Seiferth, J., Marinello, I., Jung, B. A., Wriedt, S., Jacobs, C., & Wehrbein, H. (2012) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s00056-012-0097-9 · Cited by 161
Miethke, R., & Vogt, S. (2005) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s00056-005-0436-1 · Cited by 154
Clements, K. M., Bollen, A., Huang, G. J., King, G., Hujoel, P. P., & Ma, T. (2003) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(03)00577-8 · Cited by 130
Invisalign®: early experiences
Joffe, L. (2003) · Journal of Orthodontics · doi:10.1093/ortho/30.4.348 · Cited by 129
Miethke, R., & Brauner, K. (2007) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s00056-007-0655-8 · Cited by 95
Cited by
Advances in orthodontic clear aligner materials
Bichu, Y. M., Alwafi, A., Liu, X., Andrews, J., Ludwig, B., Bichu, A. Y., & Zou, B. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.10.006 · Cited by 274
Orthodontic treatment of patients with severe (stage IV) periodontitis
Papageorgiou, S. N., Antonoglou, G. N., Eliades, T., Martin, C., & Sanz, M. (2024) · Seminars in Orthodontics · doi:10.1053/j.sodo.2024.01.004 · Cited by 23
Esmaeili, S., Shahbazi, S., Ziaei, H., & Younessian, F. (2026) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-032-03176-1_29 · Cited by 1
Metadata
- Authors
- Haouili, N., Kravitz, N. D., Vaid, N. R., Ferguson, D. J., & Makki, L.
- Venue
- American Journal of Orthodontics and Dentofacial Orthopedics
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 158
- Issue
- 3
- Pages
- 420-425
- ISSN
- 0889-5406 (ISSN-L)
- OpenAlex
- W3038469606
- Cited by
- 443
- References
- 13
- FWCI
- 45.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.