The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Transvaginal sonographic cervical length for the prediction of spontaneous preterm birth in twin pregnancies: a systematic review and metaanalysis
Open accessAbstract
Objective To assess the accuracy of transvaginal sonographic cervical length (CL) in predicting spontaneous preterm birth in women with twin pregnancies. Study design Systematic review and metaanalysis of predictive test accuracy. Results Twenty-one studies (16 in asymptomatic women and 5 in symptomatic women) with a total of 3523 women met the inclusion criteria. Among asymptomatic women, a CL ≤20 mm 20-24 weeks’ gestation was the most accurate in predicting preterm birth <32 and <34 weeks’ gestation (pooled sensitivities, specificities, and positive and negative likelihood ratios of 39% and 29%, 96% and 97%, 10.1 and 9.0, and 0.64 and 0.74, respectively). A CL ≤25 mm 20-24 weeks’ gestation had a pooled positive likelihood ratio of 9.6 to predict preterm birth <28 weeks’ gestation. The predictive accuracy of CL for preterm birth was low in symptomatic women. Conclusion Transvaginal sonographic CL 20-24 weeks’ gestation is a good predictor of spontaneous preterm birth in asymptomatic women with twin pregnancies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Epidemiology and causes of preterm birth
Goldenberg, R. L., Culhane, J. F., Iams, J. D., & Romero, R. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60074-4 · Cited by 7,801
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Martin, J. A., Hamilton, B. E., Ventura, S. J., Menacker, F., & Park, M. M. (2002) · PubMed · Cited by 984
Martin, J. A., Hamilton, B. E., Sutton, P. D., Ventura, S. J., Menacker, F., & Munson, M. L. (2003) · PubMed · Cited by 915
Martin, J. A., Hamilton, B. E., Ventura, S. J., Menacker, F., Park, M. M., & Sutton, P. D. (2002) · PubMed · Cited by 855
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
Walter, S. D. (2002) · Statistics in Medicine · doi:10.1002/sim.1099 · Cited by 672
Martin, J. A., Hamilton, B. E., Sutton, P. D., Ventura, S. J., Menacker, F., & Kirmeyer, S. (2006) · PubMed · Cited by 662
Evidence of bias and variation in diagnostic accuracy studies
Rutjes, A. W. S., Reitsma, J. B., Di Nisio, M., Smidt, N., van Rijn, J. C., & Bossuyt, P. M. M. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.050090 · Cited by 611
Exploring sources of heterogeneity in systematic reviews of diagnostic tests
Lijmer, J. G., Bossuyt, P. M. M., & Heisterkamp, S. H. (2002) · Statistics in Medicine · doi:10.1002/sim.1185 · Cited by 446
The preterm prediction study: Risk factors in twin gestations
Goldenberg, R. L., Iams, J. D., Miodovnik, M., Van Dorsten, J. P., Thurnau, G., Bottoms, S., Mercer, B. M., Meis, P. J., Moawad, A. H., Das, A., et al. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)80051-2 · Cited by 347
No role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Norman, J. E., Mackenzie, F., Owen, P., Mactier, H., Hanretty, K., Cooper, S., Calder, A., Mires, G., Danielian, P., Sturgiss, S., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60947-8 · Cited by 295
Crane, J. M. G., & Hutchens, D. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5323 · Cited by 279
Accuracy of cervical transvaginal sonography in predicting preterm birth: a systematic review
Honest, H., Bachmann, L. M., Coomarasamy, A., Gupta, J. K., Kleijnen, J., & Khan, K. S. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.202 · Cited by 206
We should not pool diagnostic likelihood ratios in systematic reviews
Zwinderman, A. H., & Bossuyt, P. M. (2008) · Statistics in Medicine · doi:10.1002/sim.2992 · Cited by 205
Leitich, H., Brunbauer, M., Kaider, A., Egarter, C., & Husslein, P. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70407-2 · Cited by 178
Transvaginal Ultrasound in the Prediction of Preterm Delivery: Singleton and Twin Gestations
CRANE, J., VANDENHOF, M., ARMSON, B., & LISTON, R. (1997) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(97)00277-9 · Cited by 168
Hospitalisation and bed rest for multiple pregnancy
Crowther, C. A. (2001) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000110 · Cited by 162
To, M. S., da Fonseca, E. B., Molina, F. S., Cacho, A. M., & Nicolaides, K. H. (2006) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2005.11.001 · Cited by 155
Use of cervical ultrasonography in prediction of spontaneous preterm birth in triplet gestations
Guzman, E. R., Walters, C. A., O'Reilly-Green, C. P., Meirowitz, N., Gipson, K., Nigam, J., & Vintzileos, A. M. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.108875 · Cited by 132
Imseis, H. M., Albert, T. A., & Iams, J. D. (1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70032-2 · Cited by 130
Cervical Length at 23 Weeks in Twins in Predicting Spontaneous Preterm Delivery
Souka, A. P., HEATH, V., FLINT, S., SEVASTOPOULOU, I., & Nicolaides, K. H. (1999) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(99)00277-x · Cited by 129
An assessment of the use of the continuity correction for sparse data in meta-analysis
Sankey, S. S., Weissfeld, L. A., Fine, M. J., & Kapoor, W. N. (1996) · Communications in Statistics - Simulation and Computation · doi:10.1080/03610919608813357 · Cited by 123
Use of cervical ultrasonography in prediction of spontaneous preterm birth in twin gestations
Guzman, E. R., Walters, C., O'Reilly-Green, C. P., Kinzler, W. L., Waldron, R., Nigam, J., & Vintzileos, A. M. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.108896 · Cited by 109
Prediction of preterm birth by second trimester cervical sonography in twin pregnancies
Yang, J. H., Kuhlman, K. A., Daly, S., & Berghella, V. (2000) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2000.00087.x · Cited by 106
Wennerholm, U., Holm, B., Mattsby‐Baltzer, I., Nielsen, T. F., Platz‐Christensen, J. J., Sundell, G., Hosseini, N., & Hagberg, H. (1997) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1997.tb11010.x · Cited by 103
Vayssière, C., Favre, R., Audibert, F., Chauvet, M. P., Gaucherand, P., Tardif, D., Grangé, G., Novoa, A., Descamps, P., Perdu, M., et al. (2002) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2002.127380 · Cited by 85
Jorgensen, A., Alfirević, Ž., Smith, C. T., Williamson, P. R., & cerclage IPD Meta‐analysis Group (2007) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2007.01515.x · Cited by 75
Fox, N. S., Saltzman, D. H., Klauser, C. K., Peress, D. A., Gutierrez, C. V., & Rebarber, A. (2009) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.06.018 · Cited by 72
Gibson, J. L., Macara, L., Owen, P., Young, D., Macauley, J., & Mackenzie, F. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1048 · Cited by 69
Prophylactic oral betamimetics for reducing preterm birth in women with a twin pregnancy
Yamasmit, W., Chaithongwongwatthana, S., Tolosa, J. E., Limpongsanurak, S., Pereira, L. M., & Lumbiganon, P. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004733.pub4 · Cited by 58
Transvaginal ultrasonography of the uterine cervix in hospitalized women with preterm labor
Vendittelli, F., MAMELLE, N., Munoz, F., & Janky, E. (2001) · International Journal of Gynecology & Obstetrics · doi:10.1016/s0020-7292(00)00313-1 · Cited by 51
How to identify twins at low risk of spontaneous preterm delivery
Sperling, L., Kiil, C., Larsen, L. U., Qvist, I., Bach, D., Wøjdemann, K. R., Bladh, A., Nikkilä, A., Jørgensen, C., Skajaa, K., et al. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1938 · Cited by 45
Arabin, B., Roos, C., Kollen, B. J., & van Eyck, J. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2694 · Cited by 38
Prophylactic oral betamimetics for reducing preterm birth in women with a twin pregnancy
Yamasmit, W., Chaithongwongwatthana, S., Tolosa, J. E., Limpongsanurak, S., Pereira, L. M., & Lumbiganon, P. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004733.pub2 · Cited by 31
Soriano, D., Weisz, B., Seidman, D. S., Chetrit, A., Schiff, E., Lipitz, S., & Achiron, R. (2002) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1046/j.0001-6349.2001.00466.x · Cited by 30
Prediction of Spontaneous Preterm Delivery in Twin Pregnancies By Cervical Length at Mid-Gestation
Klein, K., Gregor, H., Hirtenlehner, K., Stammler‐Safar, M., Witt, A., Hanslik, A., Husslein, P. W., & Krampl, E. (2008) · Twin Research and Human Genetics · doi:10.1375/twin.11.5.552 · Cited by 30
González, N. A., Bige, V., Kandoussi, S., Graesslin, O., Quéreux, C., & Gabriel, R. (2004) · Gynécologie Obstétrique & Fertilité · doi:10.1016/j.gyobfe.2003.12.005 · Cited by 17
Cervical length, multifetal pregnancy reduction, and prediction of preterm birth
Fait, G., Har-Toov, J., Gull, I., Lessing, J. B., Jaffa, A. J., & Wolman, I. (2005) · Journal of Clinical Ultrasound · doi:10.1002/jcu.20159 · Cited by 15
Aboulghar, M. M., Aboulghar, M. A., Mourad, L. M., Serour, G. I., & Mansour, R. (2009) · Reproductive BioMedicine Online · doi:10.1016/s1472-6483(10)60269-6 · Cited by 12
Granovsky, S. G., Farine, D., Barrett, J., Eyk, N. V., Ryan, G., Seaward, P. G. R., & Windrim, R. C. (1998) · Cited by 9
Cited by
ISUOG Practice Guidelines: role of ultrasound in twin pregnancy
Khalil, A., Rodgers, M., Baschat, A., Bhide, A., Gratacos, E., Hecher, K., Kilby, M. D., Lewi, L., Nicolaides, K. H., Oepkes, D., et al. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15821 · Cited by 645
Romero, R., Nicolaides, K., Conde-Agudelo, A., Tabor, A., O'Brien, J. M., Cetingoz, E., Da Fonseca, E., Creasy, G. W., Klein, K., Rode, L., et al. (2012) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.12.003 · Cited by 580
Self-citationRomero, R., Conde-Agudelo, A., Da Fonseca, E., O’Brien, J. M., Cetingoz, E., Creasy, G. W., Hassan, S. S., & Nicolaides, K. H. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.11.576 · Cited by 522
“A short cervix, conventionally defined as a transvaginal sonographic cervical length ≤25 mm in the midtrimester of pregnancy, is a powerful risk factor for spontaneous preterm birth and has a high predictive accuracy for spontaneous preterm birth <34 weeks of gestation, and a moderate to low predictive accuracy for sp…”
BackgroundSelf-citationPrediction and Prevention of Spontaneous Preterm Birth
(2021) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000004479 · Cited by 377
Conde-Agudelo, A., Romero, R., Da Fonseca, E., O’Brien, J. M., Cetingoz, E., Creasy, G. W., Hassan, S. S., Erez, O., Pacora, P., & Nicolaides, K. H. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.03.028 · Cited by 168
“A short cervix, conventionally defined as a transvaginal sonographic cervical length ≤25mm in the midtrimester of pregnancy, is also an important risk factor for this condition and has emerged as one of the strongest and most consistent predictors of preterm birth in asymptomatic women with a singleton or twin gestati…”
Self-citation
Metadata
- Authors
- Conde-Agudelo, A., Romero, R., Hassan, S. S., & Yeo, L.
- Venue
- American Journal of Obstetrics and Gynecology
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 203
- Issue
- 2
- Pages
- 128.e1-128.e12
- ISSN
- 0002-9378 (ISSN-L)
- OpenAlex
- W1972534525
- Cited by
- 256
- References
- 48
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.