Cited by 26Cardiac Arrhythmias and TreatmentsCardiac electrophysiology and arrhythmiasCardiac pacing and defibrillation studies

Demonstration of anatomic reentrant circuit in verapamil-sensitive atrial tachycardia originating from the atrioventricular annulus other than the vicinity of the atrioventricular node

Yamabe, Hiroshige, Okumura, Ken, Koyama, Junjiroh, Kanazawa, Hisanori, Hoshiyama, Tadashi, Ogawa, Hisao·2014·The American Journal of Cardiology

Abstract

The mechanism and tachycardia circuit of verapamil-sensitive atrial tachycardia originating from the atrioventricular annulus (AVA-AT) other than the atrioventricular node vicinity are not well clarified. In 23 patients, we examined the mechanism and anatomic tachycardia circuit of AVA-AT. While recording the atrial electrogram at the earliest atrial activation site (EAAS) during tachycardia, rapid atrial pacing at a rate 5 beats/min faster than the tachycardia rate was delivered from multiple sites of the right atrium (RA) to demonstrate manifest entrainment and define the direction of proximity of slow conduction area (SCA) of reentry circuit. When EAAS was orthodromically captured, radiofrequency energy was delivered starting at a site 2 cm away from the EAAS in the direction of entrainment pacing site. Then application site was gradually advanced toward the EAAS until termination of tachycardia to define the entrance of SCA of reentry circuit. Manifest entrainment was demonstrated in all AVA-ATs. The EAAS, distributed along the tricuspid annulus from 3- to the 12-o'clock position, was orthodromically captured by pacing delivered from high anterolateral RA (n = 6), high anteroseptal RA (n = 7), high posteroseptal RA (n = 3), low anterolateral RA (n = 6), and coronary sinus ostium (n = 1). Radiofrequency energy delivery to the site, 10.4 ± 2.4 mm proximal to the EAAS where the atrial electrogram was observed 13.9 ± 5.7 ms later than the EAAS, terminated AVA-AT immediately after the onset of energy delivery (2.9 ± 1.1 seconds). In conclusion, it was shown that the AVA-AT is organized as reentry involving the verapamil-sensitive SCA with its entrance and exit at different distinct locations.

Integrity signals

Registry

Crossref · 10.1016/j.amjcard.2014.03.011

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yamabe, H., Okumura, K., Koyama, J., Kanazawa, H., Hoshiyama, T., & Ogawa, H.
Affiliations
  • Kumamoto University (JP)
  • Hirosaki University (JP)
Corresponding author
Yamabe, Hiroshige
Venue
The American Journal of Cardiology
Publisher
Elsevier BV
Published
2014-06
Volume
113
Issue
11
Pages
1822-1828
ISSN
0002-9149 (ISSN-L)
OpenAlex
W2046770586
Cited by
26
References
20
Citations by year
2026: 2 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 1 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 3
FWCI
1.14
Type
journal article
Language
en
Open access
closed
Locations
  • The American Journal of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Ministry of Education, Culture, Sports, Science and Technology
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
reentrant circuit, atrial electrograms, radiofrequency ablation, tricuspid annulus, atrioventricular node
MeSH terms
Adult, Aged, Aged, 80 and over, Anti-Arrhythmia Agents, Atrioventricular Node, Cardiac Pacing, Artificial, Female, Heart Atria, Heart Conduction System, Heart Rate, Humans, Male, Middle Aged, Tachycardia, Atrioventricular Nodal Reentry, Verapamil, Treatment Outcome, Catheter Ablation, Electrophysiologic Techniques, Cardiac

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review