The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Pattern recognition-based chillers fault detection method using Support Vector Data Description (SVDD)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks: A Comprehensive Foundation
Haykin, S. (1998) · Cited by 30,070
Support Vector Data Description
Tax, D. M. J., & Duin, R. P. W. (2004) · Machine Learning · doi:10.1023/b:mach.0000008084.60811.49 · Cited by 3,512
Support vector domain description
Tax, D. M. J., & Duin, R. P. W. (1999) · Pattern Recognition Letters · doi:10.1016/s0167-8655(99)00087-2 · Cited by 1,614
Katipamula, S., & Brambley, M. R. (2005) · HVAC&R Research · doi:10.1080/10789669.2005.10391123 · Cited by 936
Applications of artificial neural-networks for energy systems
Kalogirou, S. A. (2000) · Applied Energy · doi:10.1016/s0306-2619(00)00005-2 · Cited by 933
Importance of occupancy information for building climate control
Oldewurtel, F., Sturzenegger, D., & Morari, M. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.06.014 · Cited by 382
Fault detection and diagnosis in process data using one-class support vector machines
Mahadevan, S., & Shah, S. L. (2009) · Journal of Process Control · doi:10.1016/j.jprocont.2009.07.011 · Cited by 368
AHU sensor fault diagnosis using principal component analysis method
Wang, S., & Xiao, F. (2003) · Energy and Buildings · doi:10.1016/j.enbuild.2003.10.002 · Cited by 258
Self-citationWang, S., & Cui, J. (2005) · Applied Energy · doi:10.1016/j.apenergy.2004.11.002 · Cited by 200
Self-citationDu, Z., Jin, X., & Yang, Y. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.01.015 · Cited by 141
Batch process monitoring based on support vector data description method
Ge, Z., Gao, F., & Song, Z. (2011) · Journal of Process Control · doi:10.1016/j.jprocont.2011.02.004 · Cited by 130
Study on a hybrid SVM model for chiller FDD applications
Han, H., Gu, B., Kang, J., & Li, Z. (2010) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2010.10.021 · Cited by 128
Han, H., Cao, Z., Gu, B. Q., & Ren, N. (2010) · Science and Technology for the Built Environment · doi:10.1080/10789669.2010.10390906 · Cited by 115
Fault detection and diagnosis based on improved PCA with JAA method in VAV systems
Du, Z., Jin, X., & Wu, L. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.08.011 · Cited by 114
Multiple faults diagnosis for sensors in air handling unit using Fisher discriminant analysis
Du, Z., & Jin, X. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.06.032 · Cited by 91
A boundary method for outlier detection based on support vector domain description
Guo, S., Chen, L., & Tsai, J. S. H. (2008) · Pattern Recognition · doi:10.1016/j.patcog.2008.07.003 · Cited by 81
A fault detection technique for air-source heat pump water chiller/heaters
Chen, Y., & Lan, L. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.03.007 · Cited by 80
A Novel Strategy for the Fault Detection and Diagnosis of Centrifugal Chiller Systems
Zhou, Q., Wang, S., & Xiao, F. (2009) · Science and Technology for the Built Environment · doi:10.1080/10789669.2009.10390825 · Cited by 78
Self-citationDetection and diagnosis for sensor fault in HVAC systems
Du, Z., & Jin, X. (2006) · Energy Conversion and Management · doi:10.1016/j.enconman.2006.09.023 · Cited by 73
A diagnostic tool for online sensor health monitoring in air-conditioning systems
Xiao, F., Wang, S., & Zhang, J. (2005) · Automation in Construction · doi:10.1016/j.autcon.2005.06.001 · Cited by 71
Self-citationA SVDD approach of fuzzy classification for analog circuit fault diagnosis with FWT as preprocessor
Luo, H., & Wang, J. C. Y. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.02.087 · Cited by 69
Pump Failure Detection Using Support Vector Data Descriptions
Tax, D. M. J., Ypma, A., & Duin, R. P. W. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48412-4_35 · Cited by 66
A robot fault diagnostic tool for flow rate sensors in air dampers and VAV terminals
Du, Z., Jin, X., & Yang, X. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.09.007 · Cited by 62
Pan, Y., Chen, J., & Dong, G. (2009) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes1447 · Cited by 34
Face detection using support vector domain description in color images
Seo, J.-W., & Ko, H. (2004) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2004.1327214 · Cited by 23
Support vector data description for calibration monitoring of remotely located microrobotic system
Cho, H. W., Jeong, M. K., & Kwon, Y. J. (2006) · Journal of Manufacturing Systems · doi:10.1016/s0278-6125(07)80009-4 · Cited by 15
Cited by
Zhao, Y., Li, T., Zhang, X., & Zhang, C. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.04.021 · Cited by 594
Self-citationImportance of occupancy information for building climate control
Oldewurtel, F., Sturzenegger, D., & Morari, M. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.06.014 · Cited by 382
Zhao, Y., Zhang, C., Zhang, Y., Wang, Z., & Li, J. (2020) · Energy and Built Environment · doi:10.1016/j.enbenv.2019.11.003 · Cited by 303
Self-citationFan, C., Xiao, F., Zhao, Y., & Wang, J. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.005 · Cited by 286
Self-citationWang, Z., Wang, Z., He, S., Gu, X., & Yan, Z. F. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.11.130 · Cited by 138
Metadata
- Authors
- Zhao, Y., Wang, S., & Xiao, F.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 112
- Pages
- 1041-1048
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2092229687
- Cited by
- 275
- References
- 26
- FWCI
- 13.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.