Fault detection and diagnosis of chillers using Bayesian network merged distance rejection and multi-source non-sensor information

Wang, Zhanwei, Wang, Zhiwei, He, Suowei, Gu, Xiaowei, Yan, Zeng Feng·2017·Applied Energy

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2016.11.130

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wang et al. treated HVAC fault-detection as a one-class classification problem using only temperature readings.

    “Wang et al. [829] treated HVAC fault-detection as a one-class classification problem, using only temperature readings for their predictions.”

    From Tackling climate change with machine learning (2023) · cites this paper as [829]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wang, Z., Wang, Z., He, S., Gu, X., & Yan, Z. F.
Affiliations
Xi'an University of Architecture and Technology (CN)
Corresponding author
Wang, Zhiwei
Venue
Applied Energy
Publisher
Elsevier BV
Published
2017-02
Volume
188
Pages
200-214
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2559976359
Cited by
138
References
39
Citations by year
2026: 6 · 2025: 19 · 2024: 11 · 2023: 9 · 2022: 23 · 2021: 17 · 2020: 21 · 2019: 11 · 2018: 19 · 2017: 2
FWCI
8.97
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Energy (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
“Twelfth Five-Year” National Science and Technology Support Programme (2011BAJ03B06)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
Keywords
Bayesian networks, one-class classification, maintenance records, false alarm rate, refrigerant leakage, building energy efficiency

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review