A novel defrosting method using heat energy dissipated by the compressor of an air source heat pump
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Novel PCM-HE defrosting using compressor heat shortened defrosting time by 65% compared with traditional reverse-cycle method, eliminated resuming heating period, and increased total heating capacity by 14.2% and COP by 1.4%.
“The defrosting time was shortened by 65% compared with the traditional method, while the resuming heating period disappeared. In addition, the total heating capacity and COP were increased by 14.2% and 1.4%, respectively.”
Cites
Frosting performance of tube fin heat exchangers with wavy and corrugated fins
Kondepudi, S. N., & O'Neal, D. L. (1991) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(91)90040-x · Cited by 71 · see citing works
A new method of defrosting evaporator coils
Mader, G., & Thybo, C. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.01.033 · Cited by 37 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384 · see citing works
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Zhang, L., Jiang, Y., Dong, J., Yao, Y., & Deng, S. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.12.047 · Cited by 56 · see citing works
Self-citationMa, L., Sun, Y., Wang, F., Wang, M., Zhang, S., & Wang, Z. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124358 · Cited by 54 · see citing works
Xiong, T., Ying, Y., Han, B., Yan, G., & Yu, J. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2021.09.003 · Cited by 35 · see citing works
Sarmiento, A. P., de Sá Sarmiento, F. I. P., Shooshtari, A., & Ohadi, M. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123680 · Cited by 29 · see citing works
Li, Z.-L., Zhang, C.-L., Liu, H.-M., & Wang, X.-C. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121828 · Cited by 22 · see citing works
Tang, L., Liu, X., He, S., & Li, Q. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.108739 · Cited by 6 · see citing works
- Authors
- Long, Z., Jiankai, D., Yiqiang, J., & Yang, Y.
- Affiliations
- Harbin Institute of Technology (CN)
- Corresponding author
- Yiqiang, Jiang
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2014-11
- Volume
- 133
- Pages
- 101-111
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2052199840
- Cited by
- 92
- References
- 2
- Citations by year
- 2026: 6 · 2025: 12 · 2024: 9 · 2023: 8 · 2022: 8 · 2021: 4 · 2020: 5 · 2019: 7 · 2018: 7 · 2017: 12 · 2016: 5 · 2015: 7 · 2014: 2
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Energy (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- National Key Technology R&D Program (2012BAJ06B02)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- air-source heat pump, reverse cycle defrosting, energy consumption reduction, coefficient of performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review