Occupancy-based demand response and thermal comfort optimization in microgrids with renewable energy sources and energy storage
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Integration of renewable energy sources in microgrids can be achieved via demand response programs, which change the electric usage in response to changes in the availability and price of electricity over time. This paper presents a novel control algorithm for joint demand response management and thermal comfort optimization in microgrids equipped with renewable energy sources and energy storage units. The proposed work aims at covering two main gaps in current state-of-the-art demand response programs. The first gap is integrating the objective of matching energy generation and consumption with the occupant behavior and with the objective of guaranteeing thermal comfort of the occupants. The second gap is developing a scalable and robust demand response program. Large-scale nature of the optimization problem and robustness are achieved via a two-level supervisory closed-loop feedback strategy: at the lower level, each building of the microgrid employs a local closed-loop feedback controller that processes only local measurements; at the upper level, a centralized unit supervises and updates the local controllers with the aim of minimizing the aggregate energy cost and thermal discomfort of the microgrid. The effectiveness of the proposed method is validated in a microgrid composed of three buildings, a photovoltaic array, a wind turbine, and an energy storage unit. Comparisons with alternative demand response strategies reveal that the proposed strategy efficiently integrates the renewable sources; energy costs are reduced and at the same time thermal comfort of the occupants is guaranteed. Furthermore, robustness is proved via consistent improvements achieved under heterogeneous conditions (different occupancy schedules and different weather conditions).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 1×
“Many studies show that HVAC 47 operations account for nearly 50% of the energy consumed by a building [7]: furthermore, good HVAC 48 control is one of the most cost-effective option to implement demand response and improve the energy 49 efficiency of microgrids.”
BackgroundThermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Farhangi, H. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2009.934876 · Cited by 2,870
EnergyPlus: creating a new-generation building energy simulation program
Crawley, D. B., Lawrie, L. K., Winkelmann, F. C., Buhl, W. F., Huang, Y. J., Pedersen, C. O., Strand, R. K., Liesen, R. J., Fisher, D. E., Witte, M. J., et al. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00114-6 · Cited by 2,822
Hatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
Contrasting the capabilities of building energy performance simulation programs
Crawley, D. B., Hand, J. W., Kummert, M., & Griffith, B. T. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.10.027 · Cited by 1,858
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Overview of current and future energy storage technologies for electric power applications
Hadjipaschalis, I., Poullikkas, A., & Efthimiou, V. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.028 · Cited by 1,500
Thermal comfort and building energy consumption implications—A review
Yang, L., Yan, H., & Lam, J. C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.062 · Cited by 1,448 · cited 1×
“For example, it has been shown that raising summer set point temperature might 50 have good and universal energy saving potential as it can be applied to both new and existing buildings [8].”
BackgroundUse of model predictive control and weather forecasts for energy efficient building climate control
Oldewurtel, F., Parisio, A., Jones, C. N., Gyalistras, D., Gwerder, M., Stauch, V., Lehmann, B., & Morari, M. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2011.09.022 · Cited by 1,222
2012 American Control Conference (ACC)
(2012) · doi:10.1109/acc19473.2012 · Cited by 669
Model Predictive Control for the Operation of Building Cooling Systems
Ma, Y., Borrelli, F., Hencey, B., Coffey, B., Bengea, S., & Haves, P. (2012) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2011.2124461 · Cited by 527
Dynamic Programming and Modern Control Theory
Bellman, R., & Kalaba, R. E. (1966) · Cited by 519
2011 IEEE Congress of Evolutionary Computation (CEC)
(2011) · doi:10.1109/cec15497.2011 · Cited by 487
Ernst, B., Oakleaf, B., Ahlstrom, M., Lange, M., Moehrlen, C., Lange, B., Focken, U., & Rohrig, K. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2007.906306 · Cited by 441
Daily load profiles for residential, commercial and industrial low voltage consumers
Jardini, J. A., Tahan, C. M. V., Gouvea, M. R., Ahn, S. U., & Figueiredo, F. M. (2000) · IEEE Transactions on Power Delivery · doi:10.1109/61.847276 · Cited by 424
Importance of occupancy information for building climate control
Oldewurtel, F., Sturzenegger, D., & Morari, M. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.06.014 · Cited by 382
Predictive controllers for thermal comfort optimization and energy savings
Freire, R. Z., Oliveira, G. H. C., & Mendes, N. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.12.007 · Cited by 362
Optimal control strategy for a multi-zone air conditioning system using a genetic algorithm
MOSSOLLY, M., GHALI, K., & GHADDAR, N. (2009) · Energy · doi:10.1016/j.energy.2008.10.001 · Cited by 270
Smart grids: The energy storage problem
Lindley, D. (2010) · Nature · doi:10.1038/463018a · Cited by 263
Marzband, M., Ghadimi, M., Sumper, A., & Domínguez-García, J. L. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.056 · Cited by 245
Occupancy-based zone-climate control for energy-efficient buildings: Complexity vs. performance
Goyal, S., Ingley, H. A., & Barooah, P. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.01.039 · Cited by 225
Use of model predictive control for experimental microgrid optimization
Parisio, A., Rikos, E., Tzamalis, G., & Glielmo, L. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.027 · Cited by 223
Demand Response for Residential Appliances via Customer Reward Scheme
Vivekananthan, C., Mishra, Y., Ledwich, G., & Li, F. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2298514 · Cited by 222
Comodi, G., Giantomassi, A., Severini, M., Squartini, S., Ferracuti, F., Fonti, A., Nardi Cesarini, D., Morodo, M., & Polonara, F. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.07.068 · Cited by 219
Predictive control techniques for energy and indoor environmental quality management in buildings
Kolokotsa, D. D., Pouliezos, A. D., Stavrakakis, G. M., & Lazos, C. (2008) · Building and Environment · doi:10.1016/j.buildenv.2008.12.007 · Cited by 217
Optimal decentralized charging control algorithm for electrified vehicles connected to smart grid
Ahn, C., Li, C.-T., & Peng, H. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.06.093 · Cited by 206
Energy management in a microgrid with distributed energy resources
Zhang, L., Gari, N., & Hmurcik, L. V. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.10.065 · Cited by 203
Smart charging and appliance scheduling approaches to demand side management
Adika, C. O., & Wang, L. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.12.004 · Cited by 188
Multi-agent control system with information fusion based comfort model for smart buildings
Wang, Z., Wang, L., Dounis, A. I., & Yang, R. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.05.020 · Cited by 183
Korkas, C. D., Baldi, S., Michailidis, I., & Kosmatopoulos, E. B. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.01.145 · Cited by 174
Self-citationBroeer, T., Fuller, J., Tuffner, F., Chassin, D. P., & Djilali, N. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.06.058 · Cited by 134
Zheng, J., Chen, J., Wu, Q., & Jing, Z. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.05.023 · Cited by 103
Liu, M., Wittchen, K. B., & Heiselberg, P. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.02.003 · Cited by 87
Mathews, E. H., Arndt, D. C., Piani, C. B., & Heerden, E. V. (2000) · Applied Energy · doi:10.1016/s0306-2619(99)00035-5 · Cited by 83
Optimal operation of DC smart house system by controllable loads based on smart grid topology
Tanaka, K., Yoza, A., Ogimi, K., Yona, A., Senjyu, T. S., Funabashi, T., & Kim, C. (2011) · Renewable Energy · doi:10.1016/j.renene.2011.07.026 · Cited by 82
Tzivanidis, C., Antonopoulos, K. A., & Gioti, F. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.01.050 · Cited by 66
THE PREDICTION OF THERMAL SENSATION FROM A SIMPLE MODEL OF HUMAN PHYSIOLOGICAL REGULATORY RESPONSE.
Azer, N., & Hsu, S. (1977) · Cited by 52
Adaptive Optimal Control for Large-Scale Nonlinear Systems
Michailidis, I., Baldi, S., Kosmatopoulos, E. B., & Ioannou, P. (2017) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2017.2684458 · Cited by 48
Self-citationFares, R. L., & Webber, M. E. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.049 · Cited by 37
Cited by
Proton-conducting oxides for energy conversion and storage
Duan, C., Huang, J., Sullivan, N., & O'Hayre, R. (2020) · Applied Physics Reviews · doi:10.1063/1.5135319 · Cited by 530
Ju, L., Tan, Z., Yuan, J., Tan, Q., Li, H., & Dong, F. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.03.020 · Cited by 336
Optimal energy management strategies for energy Internet via deep reinforcement learning approach
Hua, H., Qin, Y., Hao, C., & Cao, J. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.145 · Cited by 329
Taheri, S., Hosseini, P., & Razban, A. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105067 · Cited by 263
Occupancy behavior based model predictive control for building indoor climate—A critical review
Mirakhorli, A., & Dong, B. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.07.036 · Cited by 225
Metadata
- Authors
- Korkas, C. D., Baldi, S., Michailidis, I., & Kosmatopoulos, E. B.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 163
- Pages
- 93-104
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2201582605
- Cited by
- 361
- References
- 40
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.