Operating principle of Soft Open Points for electrical distribution network operation
Open accessAbstract
Soft Open Points (SOPs) are power electronic devices installed in place of normally-open points in electrical power distribution networks. They are able to provide active power flow control, reactive power compensation and voltage regulation under normal network operating conditions, as well as fast fault isolation and supply restoration under abnormal conditions. Two control modes were developed for the operation of an SOP, using back-to-back voltage-source converters (VSCs). A power flow control mode with current control provides independent control of real and reactive power. A supply restoration mode with a voltage controller enables power supply to isolated loads due to network faults. The operating principle of the back-to-back VSCs based SOP was investigated under both normal and abnormal network operating conditions. Studies on a two-feeder medium-voltage distribution network showed the performance of the SOP under different network-operating conditions: normal, during a fault and post-fault supply restoration. During the change of network operating conditions, a mode switch method based on the phase locked loop controller was used to achieve the transitions between the two control modes. Hard transitions by a direct mode switching were noticed unfavourable, but seamless transitions were obtained by deploying a soft cold load pickup and voltage synchronization process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation
Balaguer, I. J., Lei, Q., Yang, S., Supatti, U., & Peng, F. Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049709 · Cited by 622
A spatial–temporal model for grid impact analysis of plug-in electric vehicles
Mu, Y., Wu, J., Jenkins, N., Jia, H., & Wang, C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.006 · Cited by 424
Self-citationGao, F., & Iravani, M. R. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.915950 · Cited by 388
Nikkhajoei, H., & Lasseter, R. H. (2007) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2007.385805 · Cited by 297
Hung, D. Q., Mithulananthan, N., & Bansal, R. C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.08.069 · Cited by 269
Benefits of Distribution-Level Power Electronics for Supporting Distributed Generation Growth
Bloemink, J. M., & Green, T. C. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2232313 · Cited by 248
Self-citationElectricity Distribution Network Design
Taylor, A. V. (1990) · IEE Review · doi:10.1049/ir:19900064 · Cited by 247
Stability Analysis of VSC MTDC Grids Connected to Multimachine AC Systems
Chaudhuri, N. R., Majumder, R., Chaudhuri, B., & Pan, J. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2165735 · Cited by 186
HVDC WITH VOLTAGE SOURCE CONVERTERS AND EXTRUDED CABLES FOR UP TO ±300 kV AND 1000 MW
Jacobson, B., Jiang, Y., Asplund, P. R. G., Gustafsson, M., & Bergkvist, M. (2006) · Cited by 67
Cited by
Control Techniques in AC, DC, and Hybrid AC–DC Microgrid: A Review
Sahoo, S. K., Sinha, A. K., & Kishore, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2786588 · Cited by 534
Li, P., Ji, H., Wang, C., Zhao, J., Song, G., Ding, F., & Wu, J. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2686009 · Cited by 447
Self-citationAn Overview of Soft Open Points in Electricity Distribution Networks
Jiang, X., Zhou, Y., Ming, W., Yang, P., & Wu, J. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3148599 · Cited by 278
Self-citationJi, H., Wang, C., Li, P., Ding, F., & Wu, J. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2833545 · Cited by 267
Self-citationHou, Q., Dai, N., & Huang, Y. (2024) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2024.3394049 · Cited by 42
“According to reference [45], the converter at terminal i operates in P-Q mode to control the active power transmitted between the SOP’s two sides, while the other terminal j operates in V dc -”
BackgroundMethod
Metadata
- Authors
- Cao, W., Wu, J., Jenkins, N., Wang, C., & Green, T.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 164
- Pages
- 245-257
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2203064089
- Cited by
- 300
- References
- 9
- FWCI
- 13.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.